LC1E3210P7 | Easy TeSys Control 3P 32A 1NO – Schneider Electric

SKU: LC1E3210P7

Original price was: R$693.85.Current price is: R$298.35. Excl. GST

Dispatch By : -6615 Weeks

Dispatch By : -6615 Weeks

19 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
32 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
50 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage230 V AC 50/60 Hz
Complementary
Motor power kW7.5 kW at 220/230 V AC 50/60 Hz
15 kW at 380/400 V AC
15 kW at 415/440 V AC
15 kW at 500 V AC
15 kW at 660/690 V AC
18.5 kW at 660…690 V
Pole contact composition3 NO
[Ith] conventional free air thermal current50 A (at 55 °C) for power circuit
Irms rated making capacity416 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity272 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current260 A 40 °C – 10 s for power circuit
138 A 40 °C – 60 s for power circuit
60 A 40 °C – 600 s for power circuit
Associated fuse rating63 A gG at <= 690 V coordination type 1 for power circuit
10 A gG at <= 690 V for auxiliary contact circuit conforming to IEC 60947-5-1
Average impedance2.5 mOhm – Ith 50 A 50 Hz for power circuit
Power dissipation per pole2 W AC-3
5 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability8000000 cycles
Electrical durability1000000 cycles AC-3
350000 cycles AC-1
Control circuit typeAC at 50/60 Hz
Control circuit voltage limits0.85…1.1 Uc (-5…55 °C):operational 50/60 Hz
0.3…0.6 Uc (-5…55 °C):drop-out 50/60 Hz
Inrush power in VA95 VA 50 Hz cos phi 0.75 (at 20 °C)
95 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA8.3 VA 50 Hz cos phi 0.3 (at 20 °C)
8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W for control circuit
Operating time12…22 ms on closing
4…19 ms on opening
Maximum operating rate1800 cyc/h 60 °C
Connections – terminalsPower circuit: screw clamp terminals 1 1…6 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 2.1 N.m
Auxiliary contact composition1 NO
Minimum switching voltage17 V for auxiliary contact circuit
Minimum switching current5 mA for auxiliary contact circuit
Insulation resistance> 10 MOhm for auxiliary contact circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting supportDIN rail
Plate
Environment
StandardsEN/IEC 60947-1
EN/IEC 60947-4-1
EN/IEC 60947-5-1
GB/T 14048.1
GB/T 14048.4
GB/T 14048.5
EN/IEC 60335-1:Clause 30.2
EN/IEC 60335-2-40:Annex JJ
IS/IEC 60947-1
IS/IEC 60947-4-1
IS/IEC 60947-5-1
Product certificationsCB Scheme
CCC
CE
EAC
BIS
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Height84 mm
Width56 mm
Depth86 mm
Net weight0.45 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.000 cm
Package 1 Width8.500 cm
Package 1 Length9.000 cm
Package 1 Weight457.000 g
Unit Type of Package 2S02
Number of Units in Package 224
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight11.272 kg
Unit Type of Package 3P06
Number of Units in Package 3384
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight188.352 kg
Contractual warranty
Warranty (in months)18

Customer Reviews