LC1E3810N5WB | Easy TeSys Control 3P 38A WB - Schneider Electric
LC1E3810N5WB | Easy TeSys Control 3P 38A WB - Schneider Electric Original price was: ₹12,645.00.Current price is: ₹5,437.35. Excl. GST
Back to products
LC1E40008N5WBIN | Easy TeSys Control 2NO+2NC 75A AC1 WB - Schneider Electric
LC1E40008N5WBIN | Easy TeSys Control 2NO+2NC 75A AC1 WB - Schneider Electric Original price was: ₹24,820.00.Current price is: ₹10,672.60. Excl. GST

LC1E40004N5WBIN | Easy TeSys Control 4NO 75A AC1 WB – Schneider Electric

SKU: LC1E40004N5WBIN

Original price was: ₹18,475.00.Current price is: ₹7,944.25. Excl. GST

Dispatch By : 1 Weeks

Dispatch By : 1 Weeks

19 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current75 A (at <40 °C) at <= 415 V AC AC-1 for power circuit
[Uc] control circuit voltage415 V AC 50 Hz
Complementary
Pole contact composition4 NO
Irms rated making capacity400 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity320 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current320 A 40 °C – 10 s for power circuit
165 A 40 °C – 60 s for power circuit
72 A 40 °C – 600 s for power circuit
Associated fuse rating80 A gG at <= 690 V coordination type 1 for power circuit
Average impedance1.5 mOhm – Ith 75 A 50 Hz for power circuit
Power dissipation per pole5.4 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Mechanical durability5000000 cycles
Electrical durability350000 cycles AC-1
Control circuit typeAC at 50 Hz wide range
Control circuit voltage limits0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz
0.7…1.25 Uc (-5…55 °C):operational 50 Hz
Inrush power in VA160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation6…10 W for control circuit
Operating time20…26 ms on closing
8…12 ms on opening
Maximum operating rate1200 cyc/h 60 °C
Connections – terminalsControl circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: solid
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: solid
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 5 N.m
Auxiliary contact compositionWithout
Mounting supportPlate
DIN rail
Environment
StandardsEN/IEC 60947-1
EN/IEC 60947-4-1
GB/T 14048.1
GB/T 14048.4
Product certificationsCB Scheme
CCC
CE
EAC
IP degree of protectionIP20 conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor open (6 Gn for 11 ms)
Shocks contactor closed (7 Gn for 11 ms)
Height127 mm
Width85 mm
Depth110 mm
Net weight1.3 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11 cm
Package 1 Width8.5 cm
Package 1 Length12.7 cm
Package 1 Weight1300 g
Unit Type of Package 2S03
Number of Units in Package 26
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight9.4 kg
Unit Type of Package 3P06
Number of Units in Package 348
Package 3 Height150 cm
Package 3 Width60 cm
Package 3 Length80 cm
Package 3 Weight77.2 kg
Contractual warranty
Warranty (in months)18

Customer Reviews