XVGB4SW | Tower Light - RAGB - 24V - LED - W.Buzzer - Base mounting - Schneider Electric
XVGB4SW | Tower Light - RAGB - 24V - LED - W.Buzzer - Base mounting - Schneider Electric Original price was: ₹6,638.00.Current price is: ₹3,584.52. Excl. GST
Back to products
LC1E40B01M5WB | EasyPact TVS contactor 3P(3 NO) - AC3 - 400 V 50A - 220 V AC coil wide range - Schneider Electric
LC1E40B01M5WB | EasyPact TVS contactor 3P(3 NO) - AC3 - 400 V 50A - 220 V AC coil wide range - Schneider Electric Original price was: ₹11,405.00.Current price is: ₹4,904.15. Excl. GST

LC1E40B10F7 | Easy TeSys Control 3P 40A 1NO – Schneider Electric

SKU: LC1E40B10F7

Original price was: ₹11,405.00.Current price is: ₹4,904.15. Excl. GST

Dispatch By : 4 Weeks

Dispatch By : 4 Weeks

19 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LC1E40B10F7 | Easy TeSys Control 3P 40A 1NO? This genuine Schneider Electric electrical component from the Easy TeSys range is built for industrial, commercial, and infrastructure applications, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 40 A, Power circuit: <= 690 V AC 50/60 Hz, 3P. Order part number LC1E40B10F7 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULC1E40B10F7
CategoryElectrical Component
Main
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current40 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
50 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage110 V AC 50/60 Hz
Complementary
Motor power kW11 kW at 220/230 V AC
18.5 kW at 380/400 V AC
22 kW at 415/440 V AC 50/60 Hz
22 kW at 500 V AC
30 kW at 660/690 V AC
18.5 kW at 440 V
Pole contact composition3 NO
Irms rated making capacity520 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity340 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current320 A 40 °C – 10 s for power circuit
165 A 40 °C – 60 s for power circuit
72 A 40 °C – 600 s for power circuit
Associated fuse rating63 A gG at <= 690 V coordination type 1 for power circuit
10 A gG at <= 690 V for auxiliary contact circuit conforming to IEC 60947-5-1
Average impedance2.5 mOhm – Ith 50 A 50 Hz for power circuit
Power dissipation per pole2.9 W AC-3
5 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability5000000 cycles
Electrical durability350000 cycles AC-1
800000 cycles AC-3
Control circuit typeAC at 50/60 Hz
Control circuit voltage limits0.85…1.1 Uc (-5…55 °C):operational 50/60 Hz
0.3…0.6 Uc (-5…55 °C):drop-out 50/60 Hz
Inrush power in VA95 VA 50 Hz cos phi 0.75 (at 20 °C)
95 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA8.5 VA 50 Hz cos phi 0.3 (at 20 °C)
8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W for control circuit
Operating time12…22 ms on closing
4…19 ms on opening
Maximum operating rate1800 cyc/h 60 °C
Connections – terminalsPower circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 2.1 N.m
Auxiliary contact composition1 NO
Minimum switching voltage17 V for auxiliary contact circuit
Minimum switching current5 mA for auxiliary contact circuit
Insulation resistance> 10 MOhm for auxiliary contact circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting supportPlate
DIN rail
Environment
StandardsEN/IEC 60947-1
EN/IEC 60947-4-1
EN/IEC 60947-5-1
GB/T 14048.1
GB/T 14048.4
GB/T 14048.5
EN/IEC 60335-1:Clause 30.2
EN/IEC 60335-2-40:Annex JJ
IS/IEC 60947-1
IS/IEC 60947-4-1
IS/IEC 60947-5-1
Product certificationsCB Scheme
CCC
CE
EAC
BIS
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTH (pollution degree 3) conforming to IEC 60068
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Height84 mm
Width56 mm
Depth86 mm
Product weight0.45 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.0 cm
Package 1 Width6.0 cm
Package 1 Length9.0 cm
Package 1 Weight460 g
Unit Type of Package 2S02
Number of Units in Package 224
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight11.372 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 40 A current rating — confirmed from product specifications; size wiring and terminals to match or exceed this value.
  • 1 NO (Normally Open) contact arrangement — provides the stated switching capacity for control and signalling circuits.
  • Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

❓ Frequently Asked Questions

Q: What is the significance of the 40 A rating on the LC1E40B10F7?

A: The 40 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.

Q: What does the 1 NO (Normally Open) contact configuration on the LC1E40B10F7 mean?

A: These contacts change state when the device is operated or energised. Size the contact for the actual switched load — pilot duty ratings are typically lower than the main contact rating.

Customer Reviews