LC1F2600 | UNEQUIPPED CONTACTOR 2600A 3P - Schneider Electric
LC1F2600 | UNEQUIPPED CONTACTOR 2600A 3P - Schneider Electric Original price was: ₹1,297,745.00.Current price is: ₹548,297.26. Excl. GST
Back to products
LC1F3304 | UNEQUIPPED CONTAC TO R LC1F 4P AC1 440V - Schneider Electric
LC1F3304 | UNEQUIPPED CONTAC TO R LC1F 4P AC1 440V - Schneider Electric Original price was: ₹211,765.00.Current price is: ₹176,294.36. Excl. GST

LC1F2600KUE | LC1F2600 CONTACTOR 100-250V AC/DC – Schneider Electric

SKU: LC1F2600KUE

Original price was: ₹1,063,090.00.Current price is: ₹449,155.53. Excl. GST

Dispatch By : 16 Weeks

Dispatch By : 16 Weeks

12 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeTeSys
Range of productTeSys F
Product or component typeContactor
Device short nameLC1F
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
[Uc] control circuit voltage100…250 V AC 50/60 Hz
100…250 V DC
[Ie] rated operational current2600 A (at <60 °C) AC-1
Complementary
[Uimp] rated impulse withstand voltage8 kV
[Ith] conventional free air thermal current2600 A (at 40 °C)
Rated breaking capacity3900 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current12000 A 40 °C – 10 s
9000 A 40 °C – 30 s
7000 A 40 °C – 1 min
6000 A 40 °C – 3 min
4000 A 40 °C – 10 min
Associated fuse rating2500 A gG at <= 440 V
Average impedance0.1 mOhm – Ith 2600 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1000 V conforming to UL 60947-4-1
Power dissipation per pole250 W AC-1
Overvoltage categoryIII
power pole contact composition3 NO
Irms rated making capacity3900 A conforming to IEC 60947-4-1
Control circuit voltage limitsOperational: 85…275 V AC/DC (at 55 °C)
Drop-out: 0…65 V AC 50/60 Hz (at 55 °C)
Drop-out: 0…51 V DC (at 55 °C)
Mechanical durability0.5 Mcycles
Inrush power in VA1100…2300 VA, 50/60 Hz cos phi 0.5 (at 20 °C)
Inrush power in W1300…2400 W (at 20 °C)
Hold-in power consumption in W14…18 W at 20 °C
Hold-in power consumption in VA21.1…24.5 VA, 50/60 Hz cos phi 0.5 (at 20 °C)
Maximum operating rate600 cyc/h 55 °C
Operating time54…88 ms closing
20…28 ms opening
Connections – terminalsPower circuit: bar 3 cable(s) – busbar cross section: 100 x 10 mm
Control circuit: screw clamp terminals 1 cable(s) 0.2…2.5 mm²solid
Control circuit: screw clamp terminals 1 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 0.25…2.5 mm²flexible with cable end
Tightening torquePower circuit: 52.2…63.8 N.m
Control circuit: 0.5…0.6 N.m
Mounting supportPlate
Input compatibilityPLC 24 V DC conforming to IEC 61131-2 Type 2
Input voltage limits0…5 V off-state for PLC input
11…30 V on-state for PLC input
Heat dissipation16…20 W
StandardsEN/IEC 60947-4-1
EN/IEC 60947-1
JIS C8201-4-1
UL 60947-4-1
Product certificationsCB Scheme
CCC
UL
UKCA
EAC
Compatibility codeLC1F
Control circuit typeAC at 50/60 Hz electronic
DC electronic
Environment
Ambient air temperature for operation-5…40 °C
Ambient air temperature for storage-60…80 °C
Permissible ambient air temperature around the device-40…60 °C
Height382 mm
Width519 mm
Depth251 mm
Operating altitude3000 m without derating
Net weight36 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height38.0 cm
Package 1 Width50.0 cm
Package 1 Length60.0 cm
Package 1 Weight37.22 kg