LC1G2654EHEN | ContactorTeSysGiga265 4P Std48-130V ACDC - Schneider Electric
LC1G2654EHEN | ContactorTeSysGiga265 4P Std48-130V ACDC - Schneider Electric Original price was: ₹168,440.00.Current price is: ₹75,798.00. Excl. GST
Back to products
LC1G2654KUEN | ContactorTeSysGiga265 4PStd100-250V ACDC - Schneider Electric
LC1G2654KUEN | ContactorTeSysGiga265 4PStd100-250V ACDC - Schneider Electric Original price was: ₹168,440.00.Current price is: ₹75,798.00. Excl. GST

LC1G2654EHES207N | CTR TeSysGiga265 4P Std48-130V ACDC S207 – Schneider Electric

SKU: LC1G2654EHES207N

Original price was: ₹195,275.00.Current price is: ₹87,873.75. Excl. GST

Dispatch By : 9 Weeks

Dispatch By : 9 Weeks

10 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeTeSys
Range of productTeSys Giga
Product or component typeContactor
Device short nameLC1G
Contactor applicationPower switching
Motor control
Utilisation categoryAC-1
AC-3
AC-3e
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8b
AC-8a
DC-1
DC-3
DC-5
Poles description4P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current385 A (at <40 °C) at <= 1000 V AC-1
265 A (at <60 °C) at <= 440 V AC-3
[Uc] control circuit voltage48…130 V AC 50/60 Hz
48…130 V DC
Control circuit voltage limitsOperational: 0.8 Uc Min…1.1 Uc Max (at <60 °C)
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <60 °C)
Complementary
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current385 A (at 40 °C)
Rated breaking capacity2380 A at 440 V
[Icw] rated short-time withstand current2.2 kA – 10 s
1.23 kA – 30 s
0.95 kA – 1 min
0.62 kA – 3 min
0.48 kA – 10 min
Associated fuse rating315 A aM at <= 440 V for motor
250 A aM at <= 690 V for motor
400 A gG at <= 690 V
450 A UL Type J at <= 600 V
Average impedance0.000144 Ohm
[Ui] rated insulation voltage1000 V
Power dissipation per pole20 W AC-1 – Ith 385 A
11 W AC-3 – Ith 265 A
Compatibility codeLC1G
Pole contact composition3 NO
Auxiliary contact composition1 NO + 1 NC
Motor power kW75 kW at 230 V AC 50/60 Hz (AC-3e)
132 kW at 400 V AC 50/60 Hz (AC-3e)
132 kW at 415 V AC 50/60 Hz (AC-3e)
160 kW at 440 V AC 50/60 Hz (AC-3e)
160 kW at 500 V AC 50/60 Hz (AC-3e)
200 kW at 690 V AC 50/60 Hz (AC-3e)
160 kW at 1000 V AC 50/60 Hz (AC-3e)
75 kW at 230 V AC 50/60 Hz (AC-3)
132 kW at 400 V AC 50/60 Hz (AC-3)
132 kW at 415 V AC 50/60 Hz (AC-3)
160 kW at 440 V AC 50/60 Hz (AC-3)
160 kW at 500 V AC 50/60 Hz (AC-3)
200 kW at 690 V AC 50/60 Hz (AC-3)
160 kW at 1000 V AC 50/60 Hz (AC-3)
75 kW at 230 V AC 50/60 Hz (AC-4)
132 kW at 400 V AC 50/60 Hz (AC-4)
132 kW at 415 V AC 50/60 Hz (AC-4)
150 kW at 440 V AC 50/60 Hz (AC-4)
160 kW at 500 V AC 50/60 Hz (AC-4)
160 kW at 690 V AC 50/60 Hz (AC-4)
160 kW at 1000 V AC 50/60 Hz (AC-4)
Motor power hp75 hp at 200/208 V 60 Hz
100 hp at 230/240 V 60 Hz
200 hp at 460/480 V 60 Hz
200 hp at 575/600 V 60 Hz
Irms rated making capacity3320 A at 440 V
Coil technologyBuilt-in bidirectional peak limiting
Safety reliability levelB10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability8 Mcycles
inrush power in VA (50/60 Hz, AC)780 VA
inrush power in W (DC)695 W
hold-in power consumption in VA (50/60 Hz, AC)17.6 VA
hold-in power consumption in W (DC)7.8 W
Operating time40…70 ms closing
15…50 ms opening
Maximum operating rate300 cyc/h AC-1
500 cyc/h AC-3
500 cyc/h AC-3e
150 cyc/h AC-4
Connections – terminalsPower circuit: bar 2 – busbar cross section: 32 x 10 mm
Power circuit: lugs-ring terminals 1 185 mm²
Power circuit: bolted connection
Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: flexible with cable end
Connection pitch45 mm
Mounting supportPlate
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
UL 60335-1
UL 60335-2-40:Annex JJ
Product certificationsCB Scheme
CCC
cULus
EAC
CE
UKCA
Tightening torque35 N.m
Height225 mm
Width140 mm
Depth225 mm
Net weight8.3 kg
Environment
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-60…80 °C
Mechanical robustnessVibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
ColourDark grey
Protective treatmentTH
Permissible ambient air temperature around the device-40…70 °C at Uc
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height30 cm
Package 1 Width26.5 cm
Package 1 Length37 cm
Package 1 Weight9.7 kg
Unit Type of Package 2S06
Number of Units in Package 24
Package 2 Height60 cm
Package 2 Width60 cm
Package 2 Length80 cm
Package 2 Weight46.2 kg
Contractual warranty
Warranty (in months)18

Customer Reviews