LC1G4004EHES207N | CTR TeSysGiga400 4P Std48-130V ACDC S207 - Schneider Electric
LC1G4004EHES207N | CTR TeSysGiga400 4P Std48-130V ACDC S207 - Schneider Electric Original price was: ₹282,415.00.Current price is: ₹119,320.34. Excl. GST
Back to products
LC1G400BEEA | ContactorTeSysGiga400 3P Adv 24-48V ACDC - Schneider Electric
LC1G400BEEA | ContactorTeSysGiga400 3P Adv 24-48V ACDC - Schneider Electric Original price was: ₹172,540.00.Current price is: ₹77,643.00. Excl. GST

LC1G4004LSEA | ContactorTeSysGiga400 4PAdv200-500V ACDC – Schneider Electric

SKU: LC1G4004LSEA

Original price was: ₹269,685.00.Current price is: ₹121,358.25. Excl. GST

Dispatch By : 9 Weeks

Dispatch By : 9 Weeks

17 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeTeSys
Range of productTeSys Giga
Product or component typeContactor
Device short nameLC1G
Contactor applicationPower switching
Utilisation categoryAC-3
AC-3e
AC-1
AC-5a
AC-5b
AC-6a
AC-6b
DC-1
DC-3
DC-5
Poles description4P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current400 A (at <60 °C) at <= 440 V AC-3
550 A (at <40 °C) at <= 1000 V AC-1
[Uc] control circuit voltage200…500 V AC 50/60 Hz
200…500 V DC
Control circuit voltage limitsOperational: 0.8 Uc Min…1.1 Uc Max (at <60 °C)
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <60 °C)
Complementary
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current550 A (at 40 °C)
Rated breaking capacity3480 A at 440 V
[Icw] rated short-time withstand current3.6 kA – 10 s
2.4 kA – 30 s
1.7 kA – 1 min
1.2 kA – 3 min
1.0 kA – 10 min
Associated fuse rating500 A aM at <= 440 V for motor
315 A aM at <= 690 V for motor
630 A gG at <= 690 V
600 A UL Type L at <= 600 V
Average impedance0.0001 Ohm
[Ui] rated insulation voltage1000 V
Power dissipation per pole30 W AC-1 – Ith 550 A
16 W AC-3 – Ith 400 A
Compatibility codeLC1G
Pole contact composition4 NO
Auxiliary contact composition1 NO + 1 NC
Irms rated making capacity5090 A at 440 V
Coil technologyBuilt-in bidirectional peak limiting
Safety reliability levelB10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability8 Mcycles
inrush power in VA (50/60 Hz, AC)535 VA
inrush power in W (DC)300 W
hold-in power consumption in VA (50/60 Hz, AC)15.4 VA
hold-in power consumption in W (DC)8.6 W
Operating time40…70 ms closing
15…50 ms opening
Maximum operating rate600 cyc/h AC-3
600 cyc/h AC-3e
300 cyc/h AC-1
Connections – terminalsPower circuit: bar 2 – busbar cross section: 32 x 10 mm
Power circuit: lugs-ring terminals 1 185 mm²
Power circuit: bolted connection
Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: flexible with cable end
Connection pitch45 mm
Mounting supportPlate
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
UL 60335-1
UL 60335-2-40:Annex JJ
Product certificationsCB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL
Tightening torque35 N.m
Height290 mm
Width185 mm
Depth226 mm
Net weight8.9 kg
Environment
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-60…80 °C
Mechanical robustnessVibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
ColourDark grey
Protective treatmentTH
Permissible ambient air temperature around the device-40…70 °C at Uc
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height27 cm
Package 1 Width32 cm
Package 1 Length37 cm
Package 1 Weight10.941 kg
Unit Type of Package 2P06
Number of Units in Package 28
Package 2 Height75 cm
Package 2 Width60 cm
Package 2 Length80 cm
Package 2 Weight96.028 kg
Contractual warranty
Warranty (in months)18