Placeholder
LC1G630EHES207N | CTR TeSysGiga630 3P Std48-130V ACDC S207 - Schneider Electric Original price was: ₹412,470.00.Current price is: ₹174,268.58. Excl. GST
Back to products
Placeholder
LC1G630LSES207N | CTRTeSysGiga630 3P Adv200-500V ACDC S207 - Schneider Electric Original price was: ₹291,130.00.Current price is: ₹123,002.43. Excl. GST

LC1G630LSEA | ContactorTeSysGiga630 3PAdv200-500V ACDC – Schneider Electric

SKU: LC1G630LSEA

Original price was: ₹345,175.00.Current price is: ₹145,836.44. Excl. GST

Dispatch By : 9 Weeks

Dispatch By : 9 Weeks

11 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeTeSys
Range of productTeSys Giga
Product or component typeContactor
Device short nameLC1G
Contactor applicationPower switching
Motor control
Utilisation categoryAC-1
AC-3
AC-3e
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8b
AC-8a
DC-1
DC-3
DC-5
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current1050 A (at <40 °C) at <= 1000 V AC-1
630 A (at <60 °C) at <= 440 V AC-3
[Uc] control circuit voltage200…500 V AC 50/60 Hz
200…500 V DC
Control circuit voltage limitsOperational: 0.8 Uc Min…1.1 Uc Max (at <60 °C)
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <60 °C)
Complementary
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
Rated breaking capacity5550 A at 440 V
[Icw] rated short-time withstand current5.05 kA – 10 s
4.4 kA – 30 s
3.4 kA – 1 min
2.2 kA – 3 min
1.6 kA – 10 min
Associated fuse rating630 A aM at <= 440 V for motor
500 A aM at <= 690 V for motor
1250 A gG at <= 690 V
1000 A UL Type L at <= 600 V
Average impedance0.000065 Ohm
[Ui] rated insulation voltage1000 V
Power dissipation per pole70 W AC-1 – Ith 1050 A
26 W AC-3 – Ith 630 A
Compatibility codeLC1G
Pole contact composition3 NO
Auxiliary contact composition1 NO + 1 NC
Motor power kW180 kW at 230 V AC 50/60 Hz (AC-3e)
315 kW at 400 V AC 50/60 Hz (AC-3e)
335 kW at 415 V AC 50/60 Hz (AC-3e)
355 kW at 440 V AC 50/60 Hz (AC-3e)
375 kW at 500 V AC 50/60 Hz (AC-3e)
500 kW at 690 V AC 50/60 Hz (AC-3e)
450 kW at 1000 V AC 50/60 Hz (AC-3e)
200 kW at 230 V AC 50/60 Hz (AC-3)
335 kW at 400 V AC 50/60 Hz (AC-3)
375 kW at 415 V AC 50/60 Hz (AC-3)
400 kW at 440 V AC 50/60 Hz (AC-3)
400 kW at 500 V AC 50/60 Hz (AC-3)
500 kW at 690 V AC 50/60 Hz (AC-3)
450 kW at 1000 V AC 50/60 Hz (AC-3)
180 kW at 230 V AC 50/60 Hz (AC-4)
315 kW at 400 V AC 50/60 Hz (AC-4)
335 kW at 415 V AC 50/60 Hz (AC-4)
355 kW at 440 V AC 50/60 Hz (AC-4)
375 kW at 500 V AC 50/60 Hz (AC-4)
450 kW at 690 V AC 50/60 Hz (AC-4)
355 kW at 1000 V AC 50/60 Hz (AC-4)
Motor power hp250 hp at 200/208 V 60 Hz
300 hp at 230/240 V 60 Hz
600 hp at 460/480 V 60 Hz
700 hp at 575/600 V 60 Hz
Coil technologyBuilt-in bidirectional peak limiting
Safety reliability levelB10d = 100000 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 1800000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability5 Mcycles
inrush power in VA (50/60 Hz, AC)670 VA
inrush power in W (DC)390 W
hold-in power consumption in VA (50/60 Hz, AC)17.0 VA
hold-in power consumption in W (DC)11.0 W
Operating time40…70 ms closing
15…50 ms opening
Maximum operating rate600 cyc/h AC-3
600 cyc/h AC-3e
300 cyc/h AC-1
150 cyc/h AC-4
Connections – terminalsPower circuit: bar 2 – busbar cross section: 52 x 20 mm
Power circuit: lugs-ring terminals 1 185 mm²
Power circuit: bolted connection
Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: flexible with cable end
Connection pitch70 mm
Mounting supportPlate
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-1
UL 60335-2-40:Annex JJ
Product certificationsCB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL
Tightening torque58 N.m
Height388.5 mm
Width211 mm
Depth266 mm
Net weight17.3 kg
Environment
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-60…80 °C
Mechanical robustnessVibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
ColourDark grey
Protective treatmentTH
Permissible ambient air temperature around the device-40…70 °C at Uc
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height30.500 cm
Package 1 Width34.500 cm
Package 1 Length51.000 cm
Package 1 Weight21.431 kg
Unit Type of Package 2S06
Number of Units in Package 22
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight55.862 kg
Logistical informations
Country of originCN
Contractual warranty
Warranty (in months)18

Customer Reviews