Legrand DX³ 6A Single Pole 10kA B-Curve MCB | 4113 22
₹5,812.00 Excl. GST
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Leading Brand |
| Part Number / SKU | 4113 22 |
| Category | Miniature Circuit Breaker (MCB) |
| Current Rating | 6 A |
| Breaking Capacity | 10 kA |
| Standard | IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) |
| Certifications | BIS certified where applicable |
⚡ Key Features
- Protects circuits at 6 A with 10 kA short-circuit breaking capacity — rated for light industrial and commercial distribution boards.
- Thermal-magnetic trip mechanism — bimetal element trips on sustained overload, instantaneous magnetic trip on short-circuit; two independent protection functions in one compact module.
- Manufactured to IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Leading Brand product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What load can the 4113 22 protect at its rated 6 A?
A: The 4113 22 is rated to carry and protect circuits up to 6 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 6 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What does the 10 kA breaking capacity on the 4113 22 mean in practice?
A: Breaking capacity (10 kA) is the maximum prospective short-circuit current the 4113 22 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 10 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Is the 4113 22 suitable for both single-phase and three-phase systems?
A: The 4113 22 with multiple poles can protect three-phase circuits. Each pole simultaneously interrupts one phase — ensuring all phases are de-energised on a fault.
Q: Can the 4113 22 be DIN rail mounted in any standard distribution board?
A: Yes. This Leading Brand MCB uses the standard 35mm EN 60715 DIN rail and 17.5mm module width, making it compatible with all major brand distribution boards and enclosures. Terminal capacity accommodates both rigid and flexible conductors up to the rated cross-section.
Q: What happens when the 4113 22 trips — how do I identify and reset it?
A: When the 4113 22 trips on fault, the handle moves to a midway position (between ON and OFF), distinctly visible from a distance. To reset: (1) identify and rectify the fault, (2) push the handle fully to OFF, (3) then switch back to ON. Never force-reset without investigating the fault cause.













Reviews
Clear filtersThere are no reviews yet.