LR97D38B | ELECTR. RELAY 20 A 38A 24V AC DC - Schneider Electric
₹40,700.00 Original price was: ₹40,700.00.₹18,315.00Current price is: ₹18,315.00. Excl. GST
LR9G630 | Thermal overload relay LR9G 630A push-in - Schneider Electric
₹73,630.00 Original price was: ₹73,630.00.₹33,133.50Current price is: ₹33,133.50. Excl. GST
LR97D38M7 | ELECTR.RELAY 20 A 38A 220V AC – Schneider Electric
SKU:
LR97D38M7
₹35,240.00 Original price was: ₹35,240.00.₹15,858.00Current price is: ₹15,858.00. Excl. GST
Dispatch By : 13 Weeks
Dispatch By : 13 Weeks
11
People watching this product now!
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included
Dedicated account manager
Technical support
Bulk & business pricing
3-day replacement
Specifications
| Main | |
|---|---|
| Range | TeSys |
| Product name | TeSys D |
| Device short name | LR97 |
| Product or component type | Electronic overcurrent relay |
| Relay application | Overload Imax > Isetting Sensitivity to phase failure Locked rotor, mechanical jamming I > 3 x Isetting |
| Product compatibility | LC1D25…D38 |
| Network type | AC |
| [Us] rated supply voltage | 200…240 V AC |
| Thermal protection adjustment range | 20…38 A |
| [Ue] rated operational voltage | 600 V AC 50/60 Hz for power circuit conforming to CSA 600 V AC 50/60 Hz for power circuit conforming to UL 690 V AC 50/60 Hz for power circuit conforming to IEC 60947-4-1 |
| Quantity per set | Set of 10 |
| Complementary | |
| Network frequency | 50…60 Hz |
| Mounting support | Direct on contactor Rail |
| Tripping threshold | 20…34 A |
| Surge withstand | 6 kV conforming to IEC 61000-4-5 |
| Contacts type and composition | 1 C/O |
| [Ith] conventional free air thermal current | 3 A for control circuit |
| Protection type | BS fuse 3 A – for control circuit GB2 circuit breaker 3 A – for control circuit GG fuse 3 A – for control circuit |
| Maximum power | 28 W at 110 V DC conforming to IEC 60947 28 W at 220 V DC conforming to IEC 60947 55 W at 24 V DC conforming to IEC 60947 55 W at 48 V DC conforming to IEC 60947 140 VA at 48 V AC conforming to IEC 60947 360 VA at 110 V AC conforming to IEC 60947 360 VA at 220 V AC conforming to IEC 60947 70 VA at 24 V AC conforming to IEC 60947 |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Phase failure sensitivity | < 3 s |
| Reset | Automatic reset 120 s fixed Electrical by interruption of power supply for minimum 0.1 s Manual reset |
| Time range | 0.2…10 s – O-time knob 0.3…10 s – O-time knob 0.5..30 s – D-time knob |
| Signalling function | 2 LEDs |
| Connections – terminals | Control circuit: cable 1 x 1…25 mm²flexible with cable end Control circuit: cable 1 x 1…25 mm²flexible without cable end Control circuit: cable 2 x 1…25 mm²flexible without cable end Control circuit: lug-clamp 1 x 1…25 mm²flexible with cable end Control circuit: lug-clamp 1 x 1…25 mm²flexible without cable end Control circuit: lug-clamp 2 x 1…25 mm²flexible with cable end Control circuit: lug-clamp 2 x 1…25 mm²flexible without cable end Control circuit: cable 2 x 1…25 mm² Power circuit: cable 1 x 1…6 mm²flexible without cable end Power circuit: cable 1 x 2.5…10 mm²flexible with cable end Power circuit: lug-clamp 1 x 1…6 mm²flexible without cable end Power circuit: lug-clamp 1 x 2.5…10 mm²flexible with cable end |
| Tightening torque | Control circuit: 0.6…1.2 N.m on lug-clamp Power circuit: 2 N.m on cable |
| Height | 67.5 mm |
| Width | 45 mm |
| Depth | 67.5 mm |
| Net weight | 0.172 kg |
| Environment | |
| Standards | IEC 60947 IEC 60255-6 |
| Product certifications | CSA GOST UL |
| Protective treatment | TH conforming to IEC 60068 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for operation | -25…60 °C conforming to IEC 60947-4-1 |
| Ambient air temperature for storage | -30…80 °C |
| Operating altitude | 2000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Shock resistance | 15 gn 11 ms conforming to IEC 60068-2-7 |
| Vibration resistance | 4 gn conforming to IEC 60068-2-6 |
| Dielectric strength | 2 V 50 Hz conforming to IEC 60255-5 |
| Resistance to electrostatic discharge | 6 kV in indirect mode 8 kV in air |
| Resistance to radiated fields | 10 V/m level 3 |
| Resistance to fast transients | 2 kV |
| Disturbance radiated/conducted | 10 V conforming to EN 61000-4-6 Class A conforming to EN 55011 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.500 cm |
| Package 1 Width | 7.500 cm |
| Package 1 Length | 8.000 cm |
| Package 1 Weight | 190.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.820 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 60.000 cm |
| Package 3 Weight | 85.120 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
Customer Reviews
Related Products
XB5AR31N | Push button, Harmony XB5N XB7N, plastic, mushroom, green, 60mm, spring return, unmarked, 1 NO – Schneider Electric
SKU:
XB5AR31N
ZB2BW36C | Ø 22 mm fixing hole – push button head with blue lamp – Schneider Electric
SKU:
ZB2BW36C
MS13MD09 | 7MDL, 1HP 3 PHASE DOL STARTER – Schneider Electric
SKU:
MS13MD09
30002572 | EM1200 Energy meter Cl 0.5 RS485 LCD – Schneider Electric
SKU:
30002572