LTMCU | CONTROL OPERATOR UNIT - Schneider Electric
₹67,285.00 Original price was: ₹67,285.00.₹35,829.26Current price is: ₹35,829.26. Excl. GST
LTMR08MBD | CONTROLLER MODBUS 0,4 8A 24VDC - Schneider Electric
₹114,420.00 Original price was: ₹114,420.00.₹60,928.65Current price is: ₹60,928.65. Excl. GST
LTMR08CBD | CONTROLLER CANOPEN 0,4 8A 24VDC – Schneider Electric
SKU:
LTMR08CBD
₹121,125.00 Original price was: ₹121,125.00.₹64,499.06Current price is: ₹64,499.06. Excl. GST
Dispatch By : 10 Weeks
Dispatch By : 10 Weeks
12
People watching this product now!
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included
Dedicated account manager
Technical support
Bulk & business pricing
3-day replacement
Specifications
| Main | |
|---|---|
| Range | TeSys |
| Product name | TeSys T |
| Device short name | LTMR |
| Product or component type | Motor controller |
| Device application | Equipment monitoring and control |
| Measurement current | 0.4…8 A |
| [Us] rated supply voltage | 24 V DC |
| Current consumption | 56…127 mA |
| Supply voltage limits | 20.4…26.24 V DC |
| Communication port protocol | CANopen |
| Bus type | CANopen ISO 1198 interface, addressing 1…127, transmission rate 10…1000 kbit/s, SUB-D 9 with 4 twisted shielded pairs cable CANopen ISO 1198 interface, addressing 1…127, transmission rate 10…1000 kbit/s, terminal block with 4 twisted shielded pairs cable |
| Complementary | |
| [Ui] rated insulation voltage | 690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508 |
| [Uimp] rated impulse withstand voltage | 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 |
| Short-circuit withstand | 100 kA conforming to EN/IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for output 0.5 A gG for control circuit |
| Protection type | Overload (long time) Phase failure Load fluctuation Phase imbalance Reverse polarity protection Thermal protection Thermal overload protection Earth-leakage protection Power factor variation Overload Locked rotor |
| Network and machine diagnosis type | Trip context information Remaining operating time before overload tripping Starting current and time Event recording Motor control command recording Running hours counter/operating time Waiting time after overload tripping Trip history information Phase fault and earth fault trip counters Fault recording |
| Logic input number | 6 |
| Input current | 7 mA |
| Current state 0 guaranteed | Logic input: < 5 V and <= 15 mA for 5 ms |
| Current state 1 guaranteed | Logic input: < 15 V and 2…15 mA for 15 ms |
| maximum output switching frequency | 2 Hz |
| Load current | 5 A at 250 V AC for logic output 5 A at 30 V DC for logic output |
| Permissible power | 480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) |
| maximum operating rate | 1800 cyc/h |
| Contacts type and composition | 1 NO + 1 NC fault signal 3 NO |
| Metering type | Average current Iavg Phase current I1, I2, I3 RMS Temperature Earth-fault current Imbalance current |
| Measurement accuracy | 5…15 % earth fault current internal measurement 1 % voltage (100…830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 1 % current 5 % active and reactive power |
| Overvoltage category | III |
| Connection pitch | 5.08 mm |
| Connections – terminals | Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG…14 AWG) flexible with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG…14 AWG) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG…14 AWG) flexible without cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG…14 AWG) solid without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (24 AWG…14 AWG) flexible with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG…14 AWG) flexible without cable end Control circuit: connector 2 cable(s) 0.5…1.5 mm² (24 AWG…14 AWG) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (24 AWG…14 AWG) solid without cable end |
| Tightening torque | Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm |
| Pollution degree | 3 |
| Electromagnetic compatibility | Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 |
| Width | 91 mm |
| Height | 61 mm |
| Depth | 122.5 mm |
| Net weight | 0.53 kg |
| Web services | Web server |
| Compatibility code | LTMR |
| Environment | |
| Standards | EN 60947-4-1 CSA C22.2 No 14 IEC 60947-4-1 UL 508 IACS E10 |
| Product certifications | ATEX C-Tick EAC LROS (Lloyds register of shipping) NOM BV RINA KERI ABS UL CSA DNV RMRoS GL CCC |
| Protective treatment | 12 x 24 hour cycles conforming to EN/IEC 60068-2-30 48 h conforming to EN/IEC 60070-2-11 TH conforming to EN/IEC 60068 |
| Fire resistance | 650 °C conforming to EN/IEC 60695-2-12 960 °C conforming to UL 94 |
| Ambient air temperature for operation | -20…60 °C |
| Ambient air temperature for storage | -40…80 °C |
| Operating altitude | <= 2000 m without derating |
| Mechanical robustness | Vibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6 Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6 Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 |
| IP degree of protection | IP20 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.0 cm |
| Package 1 Width | 10.0 cm |
| Package 1 Length | 13.5 cm |
| Package 1 Weight | 510.0 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 5.452 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
Customer Reviews
Related Products
XB5AR31N | Push button, Harmony XB5N XB7N, plastic, mushroom, green, 60mm, spring return, unmarked, 1 NO – Schneider Electric
SKU:
XB5AR31N
ZB2BW36C | Ø 22 mm fixing hole – push button head with blue lamp – Schneider Electric
SKU:
ZB2BW36C
MS13MD09 | 7MDL, 1HP 3 PHASE DOL STARTER – Schneider Electric
SKU:
MS13MD09
30002572 | EM1200 Energy meter Cl 0.5 RS485 LCD – Schneider Electric
SKU:
30002572