LTMR08PFM | CONTROLLER PROFIBUS 0,4 8A 115 230VAC - Schneider Electric
LTMR08PFM | CONTROLLER PROFIBUS 0,4 8A 115 230VAC - Schneider Electric Original price was: ₹133,075.00.Current price is: ₹70,862.44. Excl. GST
Back to products
LTMR100MBD | CONTROLLER MODBUS 5 100A 24VDC - Schneider Electric
LTMR100MBD | CONTROLLER MODBUS 5 100A 24VDC - Schneider Electric Original price was: ₹120,075.00.Current price is: ₹63,939.94. Excl. GST

LTMR100CFM | CONTROLLER CANOPEN 5 100A 115 230VAC – Schneider Electric

SKU: LTMR100CFM

Original price was: ₹126,355.00.Current price is: ₹67,284.04. Excl. GST

Dispatch By : 1 Weeks

Dispatch By : 1 Weeks

15 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeTeSys
Product nameTeSys T
Device short nameLTMR
Product or component typeMotor controller
Device applicationEquipment monitoring and control
Measurement current5…100 A
[Us] rated supply voltage100…240 V AC 50/60 Hz
Current consumption8…62.8 mA
Supply voltage limits93.5…264 V AC
Communication port protocolCANopen
Bus typeCANopen ISO 1198 interface, addressing 1…127, transmission rate 10…1000 kbit/s, SUB-D 9 with 4 twisted shielded pairs cable
CANopen ISO 1198 interface, addressing 1…127, transmission rate 10…1000 kbit/s, terminal block with 4 twisted shielded pairs cable
Complementary
[Ui] rated insulation voltage690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
[Uimp] rated impulse withstand voltage4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
Short-circuit withstand100 kA conforming to EN/IEC 60947-4-1
Associated fuse rating4 A gG for output
0.5 A gG for control circuit
Protection typeThermal protection
Locked rotor
Phase failure
Earth-leakage protection
Overload (long time)
Power factor variation
Phase unbalance
Load fluctuation
Thermal overload protection
Reverse polarity protection
Overload
Network and machine diagnosis typeEvent recording
Trip history information
Starting current and time
Running hours counter/operating time
Motor control command recording
Remaining operating time before overload tripping
Fault recording
Phase fault and earth fault trip counters
Waiting time after overload tripping
Trip context information
Logic input number6
Input current3.1 mA at 100 V
7.5 mA at 240 V
Current state 0 guaranteedLogic input: 0…40 V and <= 15 mA for 25 ms
Current state 1 guaranteedLogic input: 79…264 V and >= 2 mA for 25 ms
maximum output switching frequency2 Hz
Load current5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
Permissible power480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
maximum operating rate1800 cyc/h
Contacts type and composition1 NO + 1 NC fault signal
3 NO
Metering typeEarth-fault current
Phase current I1, I2, I3 RMS
Imbalance current
Temperature
Average current Iavg
Measurement accuracy5…15 % earth fault current internal measurement
1 % voltage (100…830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
5 % active and reactive power
0,02 current
Overvoltage categoryIII
Connection pitch5.08 mm
Connections – terminalsControl circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG…14 AWG) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG…14 AWG) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG…14 AWG) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG…14 AWG) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (24 AWG…14 AWG) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG…14 AWG) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (24 AWG…14 AWG) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (24 AWG…14 AWG) solid without cable end
Tightening torqueControl circuit: 0.5…0.6 N.m flat screwdriver 3 mm
Pollution degree3
Electromagnetic compatibilityElectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Width91 mm
Height61 mm
Depth122.5 mm
Net weight0.53 kg
Web servicesWeb server
Compatibility codeLTMR
Environment
StandardsIEC 60947-4-1
CSA C22.2 No 14
IACS E10
EN 60947-4-1
UL 508
Product certificationsLROS (Lloyds register of shipping)
DNV
UL
EAC
GL
CCC
BV
ABS
KERI
ATEX
NOM
RINA
RMRoS
C-Tick
CSA
Protective treatment12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
Fire resistance650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
Ambient air temperature for operation-20…60 °C
Ambient air temperature for storage-40…80 °C
Operating altitude<= 2000 m without derating
Mechanical robustnessVibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
IP degree of protectionIP20
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.0 cm
Package 1 Width10.0 cm
Package 1 Length13.5 cm
Package 1 Weight534.0 g
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight5.685 kg
Contractual warranty
Warranty (in months)18