LTMT9RJ401 | Cable for Expansion Module Tera 0.1M - Schneider Electric
₹765.00 Original price was: ₹765.00.₹428.40Current price is: ₹428.40. Excl. GST
LTMTAN21 | Expansion Tera 2AI+1AO – Schneider Electric
SKU:
LTMTAN21
₹23,605.00 Original price was: ₹23,605.00.₹13,218.80Current price is: ₹13,218.80. Excl. GST
Dispatch By : 2 Weeks
Dispatch By : 2 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included
Dedicated account manager
Technical support
Bulk & business pricing
3-day replacement
Specifications
| Main | |
|---|---|
| Range | TeSys |
| Product name | TeSys Tera |
| Device short name | LTMT |
| Product or component type | Extension module |
| Device application | Equipment monitoring and control |
| Range compatibility | TeSys TeSys Tera motor controller |
| Complementary | |
| [Ui] rated insulation voltage | 690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 |
| Protection type | Overload protection Stalled rotor Locked rotor Short-circuit Undercurrent Overcurrent Current unbalance Phase reversal Phase loss Earth fault protection internal Earth fault protection external Excessive starting time Max number of start Undervoltage Overvoltage Voltage unbalance Underfrequency Overfrequency Reacceleration Temperature protection Analog input protection Communication failure Fail to stop Under power Over power Power factor variation Anti-backspin timer Block output DI interlock protection |
| maximum output switching frequency | 2 Hz |
| maximum operating rate | 1800 cyc/h |
| Contacts type and composition | Without |
| Measurement accuracy | 1 % current (0.3…3 A) 1 % current (2.5…25 A) 3 % current (7…70 A) 3 % current (10…100 A) 1 % voltage (110…690 V) +/- 2.5 % earth fault current external measurement +/- 2.5 % earth fault current external measurement (current > 0.03 A in the 0.3…3 A range) +/- 3…5 % earth fault current internal measurement (current > 0.03 A in the 0.3…3 A range) +/- 30 min/year internal clock (current > 0.25 A in the 2.5…25 A range) +/- 3…5 % earth fault current internal measurement (current > 0.25 A in the 2.5…25 A range) +/- 3…5 % earth fault current internal measurement (current > 0.7 A in the 7…70 A range) +/- 3…5 % earth fault current internal measurement (current > 1 A in the 10…100 A range) +/- 2 % temperature +/- 2 % THD measurement +/- 2…5 % active and reactive energy +/- 3…6 % power factor |
| Mounting mode | Flush-mounted |
| Connection pitch | 5.0 mm |
| Connections – terminals | Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG…14 AWG) flexible with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG…14 AWG) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG…14 AWG) flexible without cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG…14 AWG) solid without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (24 AWG…14 AWG) flexible with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG…14 AWG) flexible without cable end Control circuit: connector 2 cable(s) 0.5…1.5 mm² (24 AWG…14 AWG) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (24 AWG…14 AWG) solid without cable end |
| Input type | Analog x2 inputs, |
| Output type | 1 xanalog |
| Electromagnetic compatibility | Electrostatic discharge, level 3, 8 kV air, 4 kV contact Fast transient bursts, level 3, 2 kV Immunity to electromagnetic interference, level 3, 10 V/m Immunity to shock waves, level 3, 2 kV |
| Depth | 90 mm |
| Height | 112 mm |
| Width | 22.5 mm |
| Tightening torque | Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm |
| Tightening torque | Control circuit: 0.5 N.m – with screwdriver flat 3 mm |
| Environment | |
| Product certifications | IEC UL cUL |
| IP degree of protection | IP20 |
| Standards | EN/IEC 60947-4-1 UL/CSA 60947-4-1 |
| Fire resistance | 650 °C conforming to EN/IEC 60695-2-12 960 °C conforming to UL 94 |
| Protective treatment | 12 x 24 hour cycles conforming to EN/IEC 60068-2-30 |
| Ambient air temperature for storage | -40…80 °C |
| Operating altitude | <= 2000 m without derating |
| Mechanical robustness | Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 Vibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6 Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6 |
| Ambient air temperature for operation | -20…70 °C |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.302 cm |
| Package 1 Width | 9.906 cm |
| Package 1 Length | 12.700 cm |
| Package 1 Weight | 131.542 g |
| Contractual warranty | |
| Warranty (in months) | 18 |
Customer Reviews
Related Products
XB5AR31N | Push button, Harmony XB5N XB7N, plastic, mushroom, green, 60mm, spring return, unmarked, 1 NO – Schneider Electric
SKU:
XB5AR31N
ZB2BW36C | Ø 22 mm fixing hole – push button head with blue lamp – Schneider Electric
SKU:
ZB2BW36C
MS13MD09 | 7MDL, 1HP 3 PHASE DOL STARTER – Schneider Electric
SKU:
MS13MD09
30002572 | EM1200 Energy meter Cl 0.5 RS485 LCD – Schneider Electric
SKU:
30002572