LTMTPBD | Main Unit Tera Profibus 24VDC - Schneider Electric
₹91,915.00 Original price was: ₹91,915.00.₹48,944.74Current price is: ₹48,944.74. Excl. GST
LTMTPTC | Expansion Tera 3TI - Schneider Electric
₹23,930.00 Original price was: ₹23,930.00.₹13,400.80Current price is: ₹13,400.80. Excl. GST
LTMTPFM | Main Unit Tera Profibus 100-240VAC/DC – Schneider Electric
SKU:
LTMTPFM
₹91,915.00 Original price was: ₹91,915.00.₹48,944.74Current price is: ₹48,944.74. Excl. GST
Dispatch By : 16 Weeks
Dispatch By : 16 Weeks
19
People watching this product now!
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included
Dedicated account manager
Technical support
Bulk & business pricing
3-day replacement
Specifications
| Main | |
|---|---|
| Range | TeSys |
| Product name | TeSys Tera |
| Device short name | LTMT |
| Product or component type | Motor controller |
| Device application | Equipment monitoring and control |
| [Us] rated supply voltage | 100…240 V AC/DC 50/60 Hz |
| Current consumption | 8…62.8 mA |
| Supply voltage limits | 85…265 V AC/DC |
| Communication port protocol | Profibus DP |
| Bus type | Profibus DP 2-wire RS 485 interface, addressing 1…125, transmission rate 9.6 kbit/s…12 Mbit/s, SUB-D 9 with 2 shielded twisted pairs Profibus DP 2-wire RS 485 interface, addressing 1…125, transmission rate 1.5 Mbit/s, terminal block with 2 shielded twisted pairs |
| Complementary | |
| [Ui] rated insulation voltage | 250 V AC conforming to IEC 60185 |
| Short-circuit withstand | 100 kA |
| Pollution degree | 3 |
| Overvoltage category | III |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Associated fuse rating | 0.5 A gG for control circuit |
| Protection type | Thermal overload protection Thermal motor protection via the drive by continuous calculation of I²t Stalled rotor Phase unbalance Phase loss Phase reversal Ground fault protection Undervoltage Overvoltage Under power/over power Load shedding scheme Voltage dip management Max number of start Excessive starting time, locked rotor Power factor variation |
| Network and machine diagnosis type | Event recording Remaining operating time before overload tripping Waiting time after overload tripping Running hours counter/operating time Trip history information Starting current and time Phase fault and earth fault trip counters Motor statistics Controller operations Start curve showing motor start record Pre-alarm of potential faults |
| Logic input number | 4 |
| Input current | 3 mA at 100…240 V |
| Current state 0 guaranteed | Digital input: 0…60 V and 5 mA for 10 ms |
| Current state 1 guaranteed | Digital input: 85…265 V and 5 mA for 10 ms |
| maximum output switching frequency | 2 Hz |
| Load current | 10 A at 250 V AC/DC 5 A at 30 V DC |
| Permissible power | 480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) |
| maximum operating rate | 1800 cyc/h |
| Contacts type and composition | 2 NO fault signal 1 NO + 1 NC fault signal |
| Metering type | Thermal memory Line, phase and average current Line to line and average voltage Motor temperature input Ground fault current Ig Active and reactive power Active and reactive energy Frequency Total voltage harmonic distortion THD (V) Total voltage harmonic distortion THD (U) Total current harmonic distortion THD (I) Phase sequence |
| Measurement accuracy | 1 % current (0.3…3 A) 1 % current (2.5…25 A) 3 % current (7…70 A) 3 % current (10…100 A) 1 % voltage (110…690 V) +/- 2.5 % earth fault current external measurement +/- 3…5 % earth fault current internal measurement (current > 0.03 A in the 0.3…3 A range) +/- 3…5 % earth fault current internal measurement (current > 0.25 A in the 2.5…25 A range) +/- 3…5 % earth fault current internal measurement (current > 0.7 A in the 7…70 A range) +/- 3…5 % earth fault current internal measurement (current > 1 A in the 10…100 A range) +/- 2 % temperature +/- 2 % THD measurement +/- 3…6 % power factor +/- 2…5 % active and reactive energy +/- 30 min/year internal clock |
| Connection pitch | 7.5 mm for supply voltage 5.0 mm for others |
| Connections – terminals | Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG…14 AWG) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG…14 AWG) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG…14 AWG) flexible with ferrule with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG…14 AWG) flexible with ferrule with cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG…14 AWG) flexible stranded with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG…14 AWG) flexible stranded with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG…14 AWG) solid with cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (24 AWG…14 AWG) solid with cable end |
| Tightening torque | Control circuit: 0.5 N.m – with screwdriver flat 3 mm |
| Width | 112 mm |
| Height | 45 mm |
| Depth | 90 mm |
| Web services | Web server |
| Environment | |
| Standards | EN/IEC 60947-4-1 UL/CSA 60947-4-1 |
| Product certifications | UL IEC cUL |
| Fire resistance | 650 °C conforming to IEC 60947-1 960 °C conforming to UL 94 |
| Ambient air temperature for operation | -20…70 °C |
| Ambient air temperature for storage | -40…80 °C |
| Operating altitude | <= 2000 m without derating |
| Mechanical robustness | Vibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-27 Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6 Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 |
| IP degree of protection | IP20 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 9.500 cm |
| Package 1 Length | 13.200 cm |
| Package 1 Weight | 300.000 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 15.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 1.464 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
Customer Reviews
Related Products
XB5AR31N | Push button, Harmony XB5N XB7N, plastic, mushroom, green, 60mm, spring return, unmarked, 1 NO – Schneider Electric
SKU:
XB5AR31N
ZB2BW36C | Ø 22 mm fixing hole – push button head with blue lamp – Schneider Electric
SKU:
ZB2BW36C
MS13MD09 | 7MDL, 1HP 3 PHASE DOL STARTER – Schneider Electric
SKU:
MS13MD09
30002572 | EM1200 Energy meter Cl 0.5 RS485 LCD – Schneider Electric
SKU:
30002572