LU2B38BL | REVERSER 38A 24VDC - Schneider Electric
LU2B38BL | REVERSER 38A 24VDC - Schneider Electric Original price was: ₹100,615.00.Current price is: ₹53,577.49. Excl. GST
Back to products
LU2BA0BL | REVERSER 12A 24VDC - Schneider Electric
LU2BA0BL | REVERSER 12A 24VDC - Schneider Electric Original price was: ₹99,030.00.Current price is: ₹52,733.48. Excl. GST

LU2B38FU | REVERSER 38A 110-240V AC/DC – Schneider Electric

SKU: LU2B38FU

Original price was: ₹100,615.00.Current price is: ₹53,577.49. Excl. GST

Dispatch By : 9 Weeks

Dispatch By : 9 Weeks

15 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeTeSys
Product nameTeSys Ultra
Device short nameLU2B
Product or component typeReversing power base
Device applicationMotor control
Motor protection
Product compatibilityControl unit LUC.X6FU
Control unit LUC.1XFU
Control unit LUC.05FU
Control unit LUC.12FU
Control unit LUC.18FU
Control unit LUC.32FU
Control unit LUC.38FU
Poles description3P
Suitability for isolationYes
[Ue] rated operational voltage690 V AC for power circuit
Network frequency40…60 Hz
[Ith] conventional free air thermal current38 A
[Ie] rated operational current35 A at <= 440 V
28 A at 500 V
24 A at 690 V
Utilisation categoryAC-43
AC-41
[Ics] rated service breaking capacity25 kA at 230 V
25 kA at 440 V
10 kA at 500 V
4 kA at 690 V
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1
type mirror contact (1 NC) conforming to IEC 60947-1
[Uc] control circuit voltage110…240 V AC 50/60 Hz
110…220 V DC
Control circuit voltage limits55 V DC drop-out
55 V AC drop-out
88…242 V DC in operation
88…264 V AC in operation
Complementary
Typical current consumption1000 mA at 110…220 V DC I maximum while closing
1000 mA at 110…240 V AC I maximum while closing
Heat dissipation3 W for control circuit with LUCA, LUCB, LUCC, LUCD
1.8 W for control circuit with LUCM
Inrush restraint duration25 ms AC 50/60 Hz
15 ms DC
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating time150 ms with change of direction for power circuit
35 ms opening for control circuit
75 ms without change of direction for power circuit
50 ms closing for control circuit
Mechanical durability15 Mcycles
maximum operating rate3600 cyc/h
Product certificationsCE
UL
CSA
CCC
EAC
StandardsEN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
CSA C22.2 No 60947-4-1, with phase barrier
[Ui] rated insulation voltage690 V conforming to IEC 60947-6-2 (pollution degree 3)
600 V conforming to UL 60947-4-1
600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-6-2
Safe separation of circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Fixing modeClipped (DIN rail)
Screw-fixed (plate)
Connections – terminalsControl circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² rigid
Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² rigid
Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid
Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end
Tightening torqueControl circuit: 0.8…1.2 N.m flat screwdriver 5 mm
Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm
Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm
Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm
Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm
Width45 mm
Height224 mm
Depth126 mm
Net weight1.27 kg
Compatibility codeLU2B
Environment
IP degree of protectionIP20 conforming to IEC 60947-1 (front panel and wired terminals)
IP20 conforming to IEC 60947-1 (other faces)
IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Protective treatmentTH conforming to IEC 60068
Ambient air temperature for operation-25…60 °C with LUCM
-25…70 °C with LUCA, LUCB, LUCC, LUCD
Ambient air temperature for storage-40…85 °C
Fire resistance960 °C parts supporting live components conforming to IEC 60695-2-12
650 °C conforming to IEC 60695-2-12
Operating altitude2000 m
Shock resistance10 gn power poles open conforming to IEC 60068-2-27
15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27
4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
Resistance to electrostatic discharge8 kV level 3 in open air conforming to IEC 61000-4-2
8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating shock wave1 kV serial mode conforming to IEC 60947-6-2
2 kV common mode conforming to IEC 60947-6-2
Resistance to fast transients2 kV class 3 serial link conforming to IEC 61000-4-4
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Resistance to radiated fields10 V/m 3 conforming to IEC 61000-4-3
Immunity to radioelectric fields10 V conforming to IEC 61000-4-6
Immunity to microbreaks3 ms for control circuit
Immunity to voltage dips70 % / 500 ms conforming to IEC 61000-4-11
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.500 cm
Package 1 Width15.000 cm
Package 1 Length25.200 cm
Package 1 Weight1.303 kg
Unit Type of Package 2S03
Number of Units in Package 22
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight3.077 kg
Contractual warranty
Warranty (in months)18

Customer Reviews