LUCB05B | ADV CONTROL 1.25-5A 24VAC - Schneider Electric
LUCB05B | ADV CONTROL 1.25-5A 24VAC - Schneider Electric Original price was: ₹25,415.00.Current price is: ₹14,232.40. Excl. GST
Back to products
LUCB05FU | ADV CONTROL 1.25-5A 110-240V - Schneider Electric
LUCB05FU | ADV CONTROL 1.25-5A 110-240V - Schneider Electric Original price was: ₹25,980.00.Current price is: ₹14,548.80. Excl. GST

LUCB05BL | ADV CONTROL 1.25-5A 24VDC – Schneider Electric

SKU: LUCB05BL

Original price was: ₹25,980.00.Current price is: ₹14,548.80. Excl. GST

Dispatch By : 2 Weeks

Dispatch By : 2 Weeks

18 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeTeSys
Range of productTeSys Ultra
Product nameTeSys Ultra
Device short nameLUCB
Product or component typeAdvanced control unit
Device applicationMotor control
Motor protection
Product specific applicationBasic protection and advanced functions, communication
main function availableProtection against overload and short-circuit
Manual reset
Earth fault protection
Protection against phase failure and phase imbalance
Product compatibilityPower base LUB12
Power base LUB32
Power base LUB38
Power base LUB120
Power base LUB320
Power base LUB380
Reversing contactor breaker LU2B12BL
Reversing contactor breaker LU2B32BL
Reversing contactor breaker LU2B38BL
[Ue] rated operational voltage690 V AC
Network frequency40…60 Hz
Load type3-phase motor – cooling: self-cooled
Utilisation categoryAC-44
AC-41
AC-43
Motor power kW1.5 kW at 400…440 V AC 50/60 Hz
2.2 kW at 500 V AC 50/60 Hz
3 kW at 690 V AC 50/60 Hz
rated motor current adjustment range1.25…5 A
Thermal overload classClass 10 – frequency limit: 40…60 Hz – temperature compensation: -25…70 °C conforming to IEC 60947-6-2
Class 10 – frequency limit: 40…60 Hz – temperature compensation: -25…70 °C conforming to UL 508
Tripping threshold14.2 x Ir +/- 20 %
Phase failure sensitivityYes
[Uc] control circuit voltage24 V DC
Complementary
Control circuit voltage limits20…27 V for DC circuit 24 V in operation
14.5 V for DC circuit 24 V drop-out
Typical current consumption130 mA at 24 V DC I maximum while closing with LUB12
220 mA at 24 V DC I maximum while closing with LUB32
220 mA at 24 V DC I maximum while closing with LUB38
60 mA at 24 V DC I rms sealed with LUB12
80 mA at 24 V DC I rms sealed with LUB32
80 mA at 24 V DC I rms sealed with LUB38
Heat dissipation2 W for control circuit with LUB12
3 W for control circuit with LUB32
3 W for control circuit with LUB38
Operating time35 ms opening with LUB12 for control circuit
35 ms opening with LUB32 for control circuit
35 ms opening with LUB38 for control circuit
70 ms closing with LUB12 for control circuit
70 ms closing with LUB32 for control circuit
70 ms closing with LUB38 for control circuit
ResetManual reset
StandardsEN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
CSA C22.2 No 60947-4-1, with phase barrier
Product certificationsCE
UL
CSA
CCC
EAC
ASEFA
ATEX
Marine
[Ui] rated insulation voltage690 V conforming to IEC 60947-6-2
600 V conforming to UL 60947-4-1
600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-6-2
Safe separation of circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Fixing modePlug-in (front face)
Width45 mm
Height66 mm
Depth60 mm
Compatibility codeLUCB
Environment
IP degree of protectionIP20 front panel and wired terminals conforming to IEC 60947-1
IP20 other faces conforming to IEC 60947-1
IP40 front panel outside connection zone conforming to IEC 60947-1
Protective treatmentTH conforming to IEC 60068
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Operating altitude2000 m
Fire resistance960 °C parts supporting live components conforming to IEC 60695-2-12
650 °C conforming to IEC 60695-2-12
Shock resistance10 gn power poles open conforming to IEC 60068-2-27
15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6
4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6
Resistance to electrostatic discharge8 kV level 3 in open air conforming to IEC 61000-4-2
8 kV level 4 on contact conforming to IEC 61000-4-2
Resistance to radiated fields10 V/m 3 conforming to IEC 61000-4-3
Resistance to fast transients2 kV class 3 serial link conforming to IEC 61000-4-4
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Immunity to radioelectric fields10 V conforming to IEC 61000-4-6
Immunity to microbreaks3 ms
Immunity to voltage dips70 % / 500 ms conforming to IEC 61000-4-11
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width8.000 cm
Package 1 Length9.000 cm
Package 1 Weight113.000 g
Unit Type of Package 2S02
Number of Units in Package 223
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight2.885 kg
Contractual warranty
Warranty (in months)18

Customer Reviews