LV481000 | Residual-current protection relay RHUs 1 - Schneider Electric
LV481000 | Residual-current protection relay RHUs 1 - Schneider Electric Original price was: ₹127,700.00.Current price is: ₹105,352.50. Excl. GST
Back to products
LV481003 | Residual-current protection relay RHU 22 - Schneider Electric
LV481003 | Residual-current protection relay RHU 22 - Schneider Electric Original price was: ₹98,980.00.Current price is: ₹81,658.50. Excl. GST

LV481001 | Residual-current protection relay RHUs 2 – Schneider Electric

SKU: LV481001

Original price was: ₹89,690.00.Current price is: ₹73,994.25. Excl. GST

Dispatch By : 7 Weeks

Dispatch By : 7 Weeks

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeVigiPacT
Device short nameRHUs
Product or component typeResidual current protection relay
Relay applicationMonitoring relay
Protection relay
Mounting supportFront panel
Earth-leakage protection classType A
Type of settingKeypad
Residual earth-leakage sensitity adjustment typeAdjustable
Earth-leakage sensitivity0.03…1 A, adjustable in step of 0.001 A
1…30 A, adjustable in step of 0.1 A
Earth-leakage time delayInstantaneous for 0.03 A
Adjustable 0…4.5 s for 0.03…30 A adjustable in step of 10 ms
Threshold setting0.015…1 A adjustable in step of 0.001 A pre-alarm
1…30 A adjustable in step of 0.1 A pre-alarm
0.03…1 A adjustable in step of 0.001 A alarm
1…30 A adjustable in step of 0.1 A alarm
Current sensors compatibilityVigiPacT TOA earth leakage current sensor
VigiPacT A earth leakage current sensor
VigiPacT L earth leakage current sensor
[Ithe] conventional enclosed thermal current8 A
Minimum load10 mA at 12 V
[Us] rated supply voltage220…240 V AC 50/60 Hz 70…110 %
Power consumption in VA8 VA
Monitored distribution system1000 V – AC at 50/60 Hz (maximum)
1000 V – AC at 400 Hz (maximum)
Earthing systemTT
IT
TN-S
[Uimp] rated impulse withstand voltage8 kV
ResetManual reset
Complementary
Test functionLocal
Remote test
Signal contacts composition1 C/O alarm fail-safe
1 NO pre-alarm fail-safe
Type of measurementEarth fault current internal measurement, range: 20…200 %, accuracy: +/- 20 %
Refresh time0.5 s
Tamperproof of settingsProtected by access code
Connections – terminalsAlarm circuit: terminal block cable(s) 0.2…2.5 mm² flexible 22 AWG…12 AWG
Alarm circuit: terminal block cable(s) 0.2…2.5 mm² rigid 22 AWG…12 AWG
Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² flexible 22 AWG…12 AWG
Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² rigid 22 AWG…12 AWG
Sensor: terminal block cable(s) 0.2…2.5 mm² flexible 22 AWG…12 AWG
Sensor: terminal block cable(s) 0.2…2.5 mm² rigid 22 AWG…12 AWG
Voltage presence: terminal block cable(s) 0.2…2.5 mm² flexible 22 AWG…12 AWG
Voltage presence: terminal block cable(s) 0.2…2.5 mm² rigid 22 AWG…12 AWG
Power supply: terminal block cable(s) 0.2…2.5 mm² flexible 22 AWG…12 AWG
Power supply: terminal block cable(s) 0.2…2.5 mm² rigid 22 AWG…12 AWG
Pre alarm: terminal block cable(s) 0.2…2.5 mm² flexible 22 AWG…12 AWG
Pre alarm: terminal block cable(s) 0.2…2.5 mm² rigid 22 AWG…12 AWG
Wire stripping lengthAlarm circuit: 6 mm
Relay test and fault reset: 6 mm
Sensor: 6 mm
Voltage presence: 6 mm
Power supply: 6 mm
Pre alarm: 6 mm
Tightening torqueAlarm circuit: 0.5 N.m
Relay test and fault reset: 0.5 N.m
Sensor: 0.5 N.m
Voltage presence: 0.5 N.m
Power supply: 0.5 N.m
Pre alarm: 0.5 N.m
StandardsEN/IEC 60947-2 Annex M
EN/IEC 60755
Width72 mm
Height72 mm
Depth117 mm
Cut-out dimensions68 x 68 mm
Net weight0.3 kg
IP degree of protectionIP40 front face: conforming to IEC 60529
IP30 other parts: conforming to IEC 60529
IP20 connection: conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Mechanical robustnessVibrations 13.2…100 Hz: 0.7 g
Vibrations 2…13.2 Hz: +/- 1 mm
Environment
Environmental characteristicExposure to damp heat not in service conforming to IEC 60068-2-30
Exposure to damp heat in service conforming to IEC 60068-2-56
Salt mist conforming to IEC 60068-2-52
Overvoltage categoryIV
Electrical shock protection classClass II
Electromagnetic compatibilityConducted and radiated emissions: , B, conforming to CISPR 11
Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6
Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2
High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5
Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4
Radiated susceptibility: , 3, conforming to IEC 61000-4-3
Relative humidity95 % at 55 °C
Pollution degree3 conforming to IEC 60664-1
Ambient air temperature for operation-25…55 °C
Ambient air temperature for storage-40…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.5 cm
Package 1 Width11.0 cm
Package 1 Length15.5 cm
Package 1 Weight430.0 g
Unit Type of Package 2S04
Number of Units in Package 224
Package 2 Height30.0 cm
Package 2 Width40.0 cm
Package 2 Length60.0 cm
Package 2 Weight11.086 kg
Logistical informations
Country of originFR
Contractual warranty
Warranty (in months)18