LV510470 | Easypact 16A, 50Ka, 3Pole Mccb – Schneider Electric
₹24,920.00 Original price was: ₹24,920.00.₹11,463.20Current price is: ₹11,463.20. Excl. GST
Dispatch By : 3 Weeks
Dispatch By : 3 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
29450 | standard auxiliary contact, circuit breaker status OF-SD-SDE-SDV, 1 single contact – Schneider Electric
LV429517 | 1 3P LONG TERMINAL SHIELD – Schneider Electric
LV429407 | MN undervoltage release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 220 to 240 VAC 50/60 Hz, 208 to 277 VAC 60 Hz – Schneider Electric
LV431563 | connection accessories, Compact NSX 100/160/250, EasyPact CVS 100/160/250, spreaders, 45 mm pitch, flat connection, 3 poles – Schneider Electric
LV429451 | SDE ADAPTER FOR TRIP UNIT NSX100-250 CI – Schneider Electric
LV429515 | 1 3P SHORT TERMINAL SHIELD – Schneider Electric
LV429387 | MX shunt trip release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 220 to 240 VAC 50/60 Hz, 208 to 277 VAC 60 Hz – Schneider Electric
LV429329 | interphase barriers, Compact NSX 100/160/250, EasyPact CVS 100/160/250, set of 6 parts – Schneider Electric
Sourced through authorised channels, the Schneider Electric LV510470 mccb from the EasyPact range delivers dependable performance for reliable circuit protection and isolation. Key ratings include 16 A at 40 °C, 3P, IP40. myelectric.in stocks the LV510470 | Easypact 16A, 50Ka, 3Pole Mccb for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LV510470 |
| Category | MCCB |
| Main | |
| Range | EasyPact |
| Range of product | EasyPact CVS100…250 |
| Product name | EasyPact CVS |
| Device short name | CVS100N |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Poles description | 3P |
| Protected poles description | 3D |
| Earth leakage protection (Vigi add on) | Without |
| [In] rated current | 16 A at 40 °C |
| Network type | AC |
| Utilisation category | Category A |
| [Icu] Breaking capacity | 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 16 A at 40 °C |
| Protection type | Short-circuit protection (magnetic) Overload protection (thermal) |
| Complementary | |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
| Network frequency | 50/60 Hz |
| Breaking capacity code | N |
| [Ics] rated service breaking capacity | 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 30000 cycles |
| Electrical durability | 12000 cycles 415 V In conforming to IEC 60947-2 |
| Control type | Toggle |
| Thermal protection adjustment range | 0…16 A |
| Long time pick-up adjustment type Ir | Adjustable |
| Long time pick-up adjustment range | 0.7…1 x In |
| Long time delay adjustment type | Fixed |
| Short-time delay adjustment type | Fixed |
| Instantaneous pick-up adjustment type Ii | Fixed |
| Instantaneous pick-up adjustment range | 190 A |
| Contact position indicator | Yes |
| Mounting support | Backplate |
| Mounting mode | Fixed |
| Upside connection | Front |
| Downside connection | Front |
| Connections – terminals | Screw connection |
| Connection pitch | 35 mm |
| Compatibility code | CVS100 |
| Width | 105 mm |
| Depth | 86 mm |
| Height | 161 mm |
| Product weight | 1.5 kg |
| Environment | |
| Standards | IEC 60947-2 EN 60947-2 |
| Product certifications | GOST IEC |
| Electrical shock protection class | Class II |
| IP degree of protection | IP40 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.094 cm |
| Package 1 Width | 13.695 cm |
| Package 1 Length | 18.884 cm |
| Package 1 Weight | 1.822 kg |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.592 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 64 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 133.472 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 50 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in high-power substations and MV/LV transformer secondaries.
- Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
- 3 Poles — three-phase feeder protection; neutral not switched (TN-C / IT systems).
- Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What load can the LV510470 protect at its rated 16 A?
A: The LV510470 is rated to carry and protect circuits up to 16 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 16 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What does the 50 kA breaking capacity on the LV510470 mean in practice?
A: Breaking capacity (50 kA) is the maximum prospective short-circuit current the LV510470 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 50 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: What trip unit type does the LV510470 use — thermal-magnetic or electronic?
A: Refer to the product label or datasheet for the exact trip unit specification. The trip unit determines adjustability and protection accuracy.
Q: Is the LV510470 suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.
Q: Can the LV510470 be motorised for remote switching and automation?
A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.