Looking for the P8016_PG_N | 16A Mini Mcb, Pg? This genuine Schneider Electric miniature circuit breaker (mcb) from the Livia range is built for reliable circuit protection and isolation, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 16 A, 1P, IK02. Order part number P8016_PG_N from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | P8016_PG_N |
| Category | Miniature Circuit Breaker (MCB) |
| Main | |
| Range | Livia |
| Device application | Control |
| Product or component type | Miniature circuit-breaker |
| Device presentation | Mechanism with central plate |
| Poles description | 1P |
| Switch additional information | Without lamp |
| Rated current | 16 A at 240 V AC |
| Number of modules | 1 module |
| fixing mode | By clips (with mounting plate) |
| Cover plate colour tint | Pristine grey |
| Complementary | |
| Marking | 0 – 1 |
| Connections – terminals | 2 screw terminals |
| Clamping connection capacity | 2 x 2.5 mm² for flexible cable(s) |
| Trip unit technology | Thermal-magnetic |
| Breaking capacity | 3 kA |
| Material | PA6 |
| Standards | EN 60898 |
| Ambient air temperature for operation | -5…45 °C |
| Ambient air temperature for storage | -20…50 °C |
| Embedding depth | 45.6 mm |
| Depth | 59.2 mm |
| Width | 17.5 mm |
| Height | 56 mm |
| Product weight | 63 g |
| Environment | |
| IK degree of protection | IK02 |
| IP degree of protection | < IP20 |
| Environmental characteristic | Liquid soap |
| Environmental health and issues | Lead free |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6 cm |
| Package 1 Width | 2.5 cm |
| Package 1 Length | 6 cm |
| Package 1 Weight | 71 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 7.2 cm |
| Package 2 Width | 6.5 cm |
| Package 2 Length | 27 cm |
| Package 2 Weight | 781 g |
| Unit Type of Package 3 | CAR |
| Number of Units in Package 3 | 60 |
| Package 3 Height | 18 cm |
| Package 3 Width | 21 cm |
| Package 3 Length | 28 cm |
| Package 3 Weight | 5.06 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 16 A rated current — provides overload and short-circuit protection for the connected circuit.
- Thermal-magnetic trip mechanism — bimetal element trips on sustained overload, instantaneous magnetic trip on short-circuit; two independent protection functions in one compact module.
- Manufactured to IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What load can the P8016_PG_N protect at its rated 16 A?
A: The P8016_PG_N is rated to carry and protect circuits up to 16 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 16 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What happens when the P8016_PG_N trips — how do I identify and reset it?
A: When the P8016_PG_N trips on fault, the handle moves to a midway position (between ON and OFF), distinctly visible from a distance. To reset: (1) identify and rectify the fault, (2) push the handle fully to OFF, (3) then switch back to ON. Never force-reset without investigating the fault cause.
Q: Is the P8016_PG_N suitable for both single-phase and three-phase systems?
A: The P8016_PG_N with multiple poles can protect three-phase circuits. Each pole simultaneously interrupts one phase — ensuring all phases are de-energised on a fault.
Q: Can the P8016_PG_N be DIN rail mounted in any standard distribution board?
A: Yes. This Schneider Electric MCB uses the standard 35mm EN 60715 DIN rail and 17.5mm module width, making it compatible with all major brand distribution boards and enclosures. Terminal capacity accommodates both rigid and flexible conductors up to the rated cross-section.