Sourced through authorised channels, the Schneider Electric RM17UBE16 electrical component from the Harmony Control Relays range delivers dependable performance for industrial, commercial, and infrastructure applications. Key ratings include IP20 (terminals). myelectric.in stocks the RM17UBE16 | OV AND UV 20..80V ACDC 24-48VAC/DC 1C/O for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | RM17UBE16 |
| Category | Electrical Component |
| Main | |
| Range of product | Harmony Control Relays |
| Relay type | Voltage control relay |
| Product or component type | Voltage control relay |
| Product specific application | For single-phase and DC supply |
| Relay name | RM17UBE |
| Relay monitored parameters | Overvoltage and undervoltage detection |
| time delay | Adjustable 0.1…10 s, 0 + 10 % Tt- time delay upon fault |
| Switching capacity in VA | 1250 VA |
| Measurement range | 20…80 V AC/DC |
| Contacts type and composition | 1 C/O |
| Complementary | |
| Reset time | 1500 ms time delay |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 5 A AC/DC |
| Supply voltage limits | 15…100 V AC/DC |
| Power consumption in VA | 0…3.9 VA AC |
| Maximum power consumption in W | 1.6 W DC |
| Control circuit frequency | 50…60 Hz +/- 10 % |
| Immunity to microbreaks | 20 ms |
| Output contacts | 1 C/O |
| nominal output current | 5 A |
| Hysteresis | 5 % fixed of threshold setting |
| Measurement accuracy | +/- 10 % of the full scale value |
| Polarity | Non reversible polarity on DC supply |
| delay at power up | 1000 ms DC 500 ms AC |
| Maximum measuring cycle | 150 ms measurement cycle as true rms value |
| Repeat accuracy | +/- 0.5 % for input and measurement circuit +/- 1 % for time delay |
| Measurement error | < 1 % over the whole range with voltage variation 0.2 %/°C with temperature variation |
| Quality labels | CE |
| Insulation resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 |
| Operating position | Any position without derating |
| Local signalling | LED (green) for power ON LED (yellow) for relay ON |
| Overvoltage category | III conforming to IEC 60664-1 |
| [Ui] rated insulation voltage | 250 V conforming to IEC 60664-1 400 V conforming to IEC 60664-1 |
| Connections – terminals | Screw terminals, 1 x 0.5…1 x 4 mm² (AWG 20…AWG 11) solid without cable end Screw terminals, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) solid without cable end Screw terminals, 1 x 0.2…2 x 2.5 mm² (AWG 24…AWG 12) flexible with cable end Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Polycarbonate |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Operating rate | <= 360 operations/hour full load |
| Utilisation category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1 |
| [Un] rated nominal voltage | , self-powered |
| Safety reliability data | MTTFd = 502.2 years B10d = 470000 |
| Control type | Without test button |
| Width | 17.5 mm |
| Product weight | 0.08 kg |
| Environment | |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
| Ambient air temperature for operation | -20…50 °C |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1 |
| Shock resistance | 5 gn conforming to IEC 60068-2-27 |
| Standards | IEC 60255-6 |
| Product certifications | C-Tick GOST GL CSA UL |
| Ambient air temperature for storage | -40…70 °C |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Directives | 73/23/EEC – low voltage directive 89/336/EEC – electromagnetic compatibility |
| Dielectric test voltage | 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1 |
| Non-dissipating shock wave | 4 kV conforming to IEC 60255-5 4 kV conforming to IEC 60664-1 4 kV conforming to IEC 61000-4-5 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.700 cm |
| Package 1 Width | 7.800 cm |
| Package 1 Length | 9.600 cm |
| Package 1 Weight | 83.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.463 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 1 CO (Changeover) contact arrangement — provides the stated switching capacity for control and signalling circuits.
- Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What does the 1 CO (Changeover) contact configuration on the RM17UBE16 mean?
A: CO (Change Over) contacts switch between two circuits — the common terminal connects to either NO or NC depending on the device state. Used for dual-purpose indication or reversing circuits.