SLASTX2 | Sensor, Wall, Humidity W/2% Accuracy, Temp, Touchscreen, Analog - Schneider Electric
SLASTX2 | Sensor, Wall, Humidity W/2% Accuracy, Temp, Touchscreen, Analog - Schneider Electric Original price was: ₹24,452.00.Current price is: ₹14,182.16. Excl. GST
Back to products
31106 | INS250 3P 250 A - SWITCH DISCONNECTOR - Schneider Electric
31106 | INS250 3P 250 A - SWITCH DISCONNECTOR - Schneider Electric Original price was: ₹33,810.00.Current price is: ₹29,076.60. Excl. GST

RM17UBE16 | OV AND UV 20..80V ACDC 24-48VAC/DC 1C/O – Schneider Electric

SKU: RM17UBE16

Original price was: ₹28,168.00.Current price is: ₹12,957.28. Excl. GST

Dispatch By : 11 Weeks

Dispatch By : 11 Weeks

14 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Sourced through authorised channels, the Schneider Electric RM17UBE16 electrical component from the Harmony Control Relays range delivers dependable performance for industrial, commercial, and infrastructure applications. Key ratings include IP20 (terminals). myelectric.in stocks the RM17UBE16 | OV AND UV 20..80V ACDC 24-48VAC/DC 1C/O for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKURM17UBE16
CategoryElectrical Component
Main
Range of productHarmony Control Relays
Relay typeVoltage control relay
Product or component typeVoltage control relay
Product specific applicationFor single-phase and DC supply
Relay nameRM17UBE
Relay monitored parametersOvervoltage and undervoltage detection
time delayAdjustable 0.1…10 s, 0 + 10 % Tt- time delay upon fault
Switching capacity in VA1250 VA
Measurement range20…80 V AC/DC
Contacts type and composition1 C/O
Complementary
Reset time1500 ms time delay
Maximum switching voltage250 V AC/DC
Minimum switching current10 mA at 5 V DC
Maximum switching current5 A AC/DC
Supply voltage limits15…100 V AC/DC
Power consumption in VA0…3.9 VA AC
Maximum power consumption in W1.6 W DC
Control circuit frequency50…60 Hz +/- 10 %
Immunity to microbreaks20 ms
Output contacts1 C/O
nominal output current5 A
Hysteresis5 % fixed of threshold setting
Measurement accuracy+/- 10 % of the full scale value
PolarityNon reversible polarity on DC supply
delay at power up1000 ms DC
500 ms AC
Maximum measuring cycle150 ms measurement cycle as true rms value
Repeat accuracy+/- 0.5 % for input and measurement circuit
+/- 1 % for time delay
Measurement error< 1 % over the whole range with voltage variation
0.2 %/°C with temperature variation
Quality labelsCE
Insulation resistance> 500 MOhm at 500 V DC conforming to IEC 60255-5
> 500 MOhm at 500 V DC conforming to IEC 60664-1
Operating positionAny position without derating
Local signallingLED (green) for power ON
LED (yellow) for relay ON
Overvoltage categoryIII conforming to IEC 60664-1
[Ui] rated insulation voltage250 V conforming to IEC 60664-1
400 V conforming to IEC 60664-1
Connections – terminalsScrew terminals, 1 x 0.5…1 x 4 mm² (AWG 20…AWG 11) solid without cable end
Screw terminals, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) solid without cable end
Screw terminals, 1 x 0.2…2 x 2.5 mm² (AWG 24…AWG 12) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) flexible with cable end
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Housing materialPolycarbonate
Mounting support35 mm symmetrical DIN rail conforming to IEC 60715
Electrical durability100000 cycles
Mechanical durability30000000 cycles
Operating rate<= 360 operations/hour full load
Utilisation categoryAC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1
AC-14 conforming to IEC 60947-5-1
AC-15 conforming to IEC 60947-5-1
DC-12 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
DC-14 conforming to IEC 60947-5-1
[Un] rated nominal voltage, self-powered
Safety reliability dataMTTFd = 502.2 years
B10d = 470000
Control typeWithout test button
Width17.5 mm
Product weight0.08 kg
Environment
Electromagnetic compatibilityEmission standard for industrial environments conforming to IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Ambient air temperature for operation-20…50 °C
Vibration resistance0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6
1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1
Shock resistance5 gn conforming to IEC 60068-2-27
StandardsIEC 60255-6
Product certificationsC-Tick
GOST
GL
CSA
UL
Ambient air temperature for storage-40…70 °C
Relative humidity95 % at 55 °C conforming to IEC 60068-2-30
IP degree of protectionIP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Directives73/23/EEC – low voltage directive
89/336/EEC – electromagnetic compatibility
Dielectric test voltage2 kV, 1 min AC 50 Hz conforming to IEC 60255-5
2 kV, 1 min AC 50 Hz conforming to IEC 60664-1
Non-dissipating shock wave4 kV conforming to IEC 60255-5
4 kV conforming to IEC 60664-1
4 kV conforming to IEC 61000-4-5
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.700 cm
Package 1 Width7.800 cm
Package 1 Length9.600 cm
Package 1 Weight83.000 g
Unit Type of Package 2S02
Number of Units in Package 248
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight4.463 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 1 CO (Changeover) contact arrangement — provides the stated switching capacity for control and signalling circuits.
  • Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

RM22UA33MR

❓ Frequently Asked Questions

Q: What does the 1 CO (Changeover) contact configuration on the RM17UBE16 mean?

A: CO (Change Over) contacts switch between two circuits — the common terminal connects to either NO or NC depending on the device state. Used for dual-purpose indication or reversing circuits.

Customer Reviews