RM22JA31MR | Current relay OC/UC 4mA 1A 24 240V 2CO - Schneider Electric
₹14,999.00 Original price was: ₹14,999.00.₹6,899.54Current price is: ₹6,899.54. Excl. GST
RM22LA32MRSP01 | LEVEL CONTROL RELAY 24...240VDC/VAC - Schneider Electric
₹12,191.00 Original price was: ₹12,191.00.₹5,607.86Current price is: ₹5,607.86. Excl. GST
RM22LA32MR | CONTROL RELAY LEVEL 2CO 24 240V – Schneider Electric
SKU:
RM22LA32MR
₹13,522.00 Original price was: ₹13,522.00.₹6,220.12Current price is: ₹6,220.12. Excl. GST
Dispatch By : 1 Weeks
Dispatch By : 1 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included
Dedicated account manager
Technical support
Bulk & business pricing
3-day replacement
Specifications
| Main | |
|---|---|
| Range of product | Harmony Control Relays |
| Relay type | Level control relay |
| Product or component type | Level control relay |
| Relay name | RM22L |
| Relay monitored parameters | Detection by resistive probes |
| time delay | Adjustable 0.1…30 s, +/- 10 % of the full scale value Tt- time delay upon fault |
| Switching capacity in VA | 2000 VA |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 8 A AC |
| Utilisation category | AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1 |
| Contacts type and composition | 2 C/O |
| Complementary | |
| Maximum switching voltage | 250 V AC |
| [Un] rated nominal voltage | 24…240 V AC/DC 50/60 Hz, non self-powered |
| Supply voltage limits | 20.4…264 V AC/DC |
| power consumption | 1.5 W DC |
| Output contacts | 2 C/O |
| nominal output current | 8 A |
| delay at power up | 2.5 s 0.6 s |
| Maximum electrode voltage | 12 V AC |
| Maximum electrode current | 1 mA |
| Repeat accuracy | +/- 2 % for time delay |
| Measurement error | < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation |
| Maximum cable distance between devices | 100 m between probe and delay |
| Sensitivity scale | 0.25…5 kOhm LS (Low Sensitivity) 5…100 kOhm St (Standard Sensitivity) 50…1000 kOhm HS (High Sensitivity) |
| Sensitivity adjustment | 5…100 % |
| Maximum supply current for sensors | 1 mA |
| Cable capacitance | 1 nF at HS (High Sensitivity) for probe cable 2.2 nF at St (Standard Sensitivity) for probe cable 4.7 nF at LS (Low Sensitivity) for probe cable |
| Overvoltage category | III conforming to IEC 60664-1 |
| Insulation | Between supply and measurement |
| Connections – terminals | Screw terminals, 2 x 0.5…2 x 2.5 mm² (20 AWG…14 AWG) solid without cable end Screw terminals, 2 x 0.2…2 x 1.5 mm² (24 AWG…16 AWG) flexible with cable end Screw terminals, 1 x 0.5…1 x 3.3 mm² (20 AWG…12 AWG) solid without cable end Screw terminals, 1 x 0.2…1 x 2.5 mm² (24 AWG…14 AWG) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Polycarbonate |
| Mounting support | 35 mm DIN rail conforming to IEC 60715 |
| Mounting position | Any position |
| Electrical durability | 100000 cycles |
| Mechanical durability | 10000000 cycles |
| Contacts material | Cadmium free |
| Measurement range | 0.25…1000 kOhm |
| Safety reliability data | MTTFd = 182.6 years B10d = 170000 |
| Width | 22.5 mm |
| Control type | With test button |
| Net weight | 0.11 kg |
| Environment | |
| Immunity to microbreaks | 100 ms DC 90 ms AC |
| Electromagnetic compatibility | Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 Immunity for industrial environments conforming to IEC 61000-6-2 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Emission standard for industrial environments conforming to IEC 61000-6-4 Electrostatic discharge – test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge – test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test – test level: 10 V/m level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test – test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4 Surge immunity test – test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5 Surge immunity test – test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5 Conducted and radiated emissions class B group 1 conforming to CISPR 11 Conducted and radiated emissions class B conforming to CISPR 22 |
| Standards | IEC 60255-1 |
| Product certifications | UL RCM CSA GL CCC CE EAC |
| Ambient air temperature for storage | -40…70 °C |
| Relative humidity | 93…97 % at 25…55 °C conforming to IEC 60068-2-30 |
| Vibration resistance | 0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6 1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6 0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6 0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27 5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Dielectric test voltage | 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.6 cm |
| Package 1 Width | 8.2 cm |
| Package 1 Length | 9.5 cm |
| Package 1 Weight | 122.0 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 5.492 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 640 |
| Package 3 Height | 60.0 cm |
| Package 3 Width | 80.0 cm |
| Package 3 Length | 60.0 cm |
| Package 3 Weight | 95.14 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
Customer Reviews
Related Products
XB5AR31N | Push button, Harmony XB5N XB7N, plastic, mushroom, green, 60mm, spring return, unmarked, 1 NO – Schneider Electric
SKU:
XB5AR31N
ZB2BW36C | Ø 22 mm fixing hole – push button head with blue lamp – Schneider Electric
SKU:
ZB2BW36C
MS13MD09 | 7MDL, 1HP 3 PHASE DOL STARTER – Schneider Electric
SKU:
MS13MD09
30002572 | EM1200 Energy meter Cl 0.5 RS485 LCD – Schneider Electric
SKU:
30002572














