RM22TA33 | 3 Phase Asymmetry control relay RM22-TA - Schneider Electric
RM22TA33 | 3 Phase Asymmetry control relay RM22-TA - Schneider Electric Original price was: ₹18,460.00.Current price is: ₹8,491.60. Excl. GST
Back to products
RM22UA21MR | CONTROL RELAY VOLT OV 8A 2CO 0.05-5V - Schneider Electric
RM22UA21MR | CONTROL RELAY VOLT OV 8A 2CO 0.05-5V - Schneider Electric Original price was: ₹9,938.00.Current price is: ₹4,571.48. Excl. GST

RM22TR31 | PH relay 8A 2CO OV/UV fail seq 200V – Schneider Electric

SKU: RM22TR31

Original price was: ₹16,429.00.Current price is: ₹7,557.34. Excl. GST

Dispatch By : 7 Weeks

Dispatch By : 7 Weeks

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
Range of productHarmony Control Relays
Relay typeControl relay
Product or component type3-phase control relay
Relay nameRM22TR
Relay monitored parametersPhase sequence
Phase failure detection
Overvoltage and undervoltage detection
Control typeWith test button
Contacts type and composition2 C/O
Complementary
[Us] rated supply voltage, self-powered
Supply voltage limits160…288 V AC
Supply frequency50…60 Hz +/- 10 %
Power consumption in VA10 VA at 240 V AC 60 Hz
Measurement range200…240 V voltage AC
Voltage detection threshold< 100 V AC
Maximum measuring cycle150 ms measurement cycle as true rms value
Threshold adjustment voltage2…20 % of Un selected
Setting accuracy of the switching threshold+/- 10 % of the full scale
Repeat accuracy+/- 0.5 % for input and measurement circuit
+/- 3 % for time delay
Measurement error< 1 % over the whole range with voltage variation
< 0.05 %/°C with temperature variation
Time delay typeAdjustable 0.1…30 s, +/- 10 % of the full scale value Tt- time delay upon fault
Setting accuracy of time delay10 %
Reset time1500 ms at maximum voltage
Response time<= 300 ms
Output contacts2 C/O
nominal output current8 A
Maximum switching voltage250 V AC
Switching capacity in VA2000 VA
Minimum switching current10 mA at 5 V DC
Maximum switching current8 A AC
Electrical durability100000 cycles
Mechanical durability10000000 cycles
Contacts materialCadmium free
Environment
Electromagnetic compatibilityImmunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1
Immunity for industrial environments conforming to IEC 61000-6-2
Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
Emission standard for industrial environments conforming to IEC 61000-6-4
Electrostatic discharge – test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge – test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
StandardsIEC 60255-1
Product certificationsCSA
CCC
EAC
RCM
CE
GL
UL
Ambient air temperature for storage-40…70 °C
-40…70 °C
Ambient air temperature for operation-20…50 °C at 60 Hz
-20…60 °C at 50 Hz AC/DC
Relative humidity93…97 % at 25…55 °C conforming to IEC 60068-2-30
Vibration resistance0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
Shock resistance15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
IP degree of protectionIP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
3 conforming to UL 508
Overvoltage categoryIII conforming to IEC 60664-1
III conforming to UL 508
Dielectric test voltage2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
Insulation resistance> 100 MOhm at 500 V DC conforming to IEC 60255-27
Connections – terminalsScrew terminals, 2 x 0.5…2 x 2.5 mm² (20 AWG…14 AWG) solid without cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (24 AWG…16 AWG) flexible with cable end
Screw terminals, 1 x 0.5…1 x 3.3 mm² (20 AWG…12 AWG) solid without cable end
Screw terminals, 1 x 0.2…1 x 2.5 mm² (24 AWG…14 AWG) flexible with cable end
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Housing materialPolycarbonate
Local signallingLED (yellow) relay ON
LED (green) power ON
Mounting support35 mm DIN rail conforming to IEC 60715
Reliability dataMTTFd = 388.1 years
B10d = 350000
Height90 mm
88.9 mm
Width22.5 mm
22.9 mm
Depth73 mm
73.7 mm
Net weight0.095 kg
0.10 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.2 cm
Package 1 Width9.5 cm
Package 1 Length2.6 cm
Package 1 Weight101.0 g
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight4.495 kg
Unit Type of Package 3PAL
Number of Units in Package 3640
Package 3 Height50.0 cm
Package 3 Width60.0 cm
Package 3 Length80.0 cm
Package 3 Weight86.18 kg
Contractual warranty
Warranty (in months)18

Customer Reviews