RSL1AB4ND | Zelio Relay,Slim Relay 1C/O 6A 60 Vdc – Schneider Electric
₹857.00 Original price was: ₹857.00.₹394.22Current price is: ₹394.22. Excl. GST
Dispatch By : 17 Weeks
Dispatch By : 17 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Looking for the RSL1AB4ND | Zelio Relay,Slim Relay 1C/O 6A 60 Vdc? This genuine Schneider Electric relay from the Harmony Electromechanical Relays range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 6 A, 45…84 V DC, IP40. Order part number RSL1AB4ND from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | RSL1AB4ND |
| Category | Relay |
| Main | |
| Range of product | Harmony Electromechanical Relays |
| Series name | RSL series |
| Product or component type | Plug-in relay |
| Relay type | Slim interface relay |
| Contact operation | Standard |
| Contacts type and composition | 1 C/O |
| Control type | Without lockable test button |
| status LED | Without |
| [Uc] control circuit voltage | 60 V DC |
| [Ithe] conventional enclosed thermal current | 6 A at -40…55 °C |
| Complementary | |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC |
| [Ie] rated operational current | 6 A (AC-1/DC-1) conforming to IEC/UL |
| minimum switching current | 10 mA |
| Minimum switching voltage | 12 V |
| Minimum switching capacity | 120 mW |
| Rated operational voltage limits | 45…84 V DC |
| [Ui] rated insulation voltage | 250 V conforming to IEC 277 V conforming to cUL |
| Operating time | 5 ms reset 12 ms |
| Maximum switching voltage | 277 V |
| Drop-out voltage threshold | >= 0.05 Uc |
| Load current | 6 A at 250 V AC 0.5 mm mounting distance |
| Maximum switching capacity | 1500 VA 50 W |
| Terminals description ISO n°1 | (11-12-14)OC (A1-A2)CO |
| Average resistance | 16600 Ohm at 23 °C +/- 15 % |
| Average coil consumption | 0.21 W |
| Mechanical durability | 10000000 cycles |
| Electrical durability | 60000 cycles, 6 A at 250 V, AC-1 C/O |
| Safety reliability data | B10d = 60000 |
| Operating rate | <= 360 cycles/hour under load <= 18000 cycles/hour no-load |
| Protection category | RT III |
| Mounting support | Socket or PCB |
| Operating position | Any position |
| Test levels | Level A group mounting |
| Device presentation | Complete product |
| Contacts material | Silver alloy (AgSnO2) |
| Shape of pin | Flat (PCB type) |
| Width | 5 mm |
| Height | 28 mm |
| Depth | 18.5 mm |
| Product weight | 0.0054 kg |
| Environment | |
| Dielectric strength | 1000 V AC between contacts 4000 V AC between coil and contact |
| Vibration resistance | +/- 1 mm (f= 10…55 Hz) conforming to IEC 60068-2-6 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| Ambient air temperature for operation | -40…55 °C |
| Standards | CSA C22.2 No 14 UL 508 IEC 61810-1 |
| Product certifications | CSA UL EAC |
| Ambient air temperature for storage | -40…70 °C |
| Shock resistance | 5 gn (duration = 11 ms) for not operating conforming to IEC 60068-2-27 5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 0.5 cm |
| Package 1 Width | 1.5 cm |
| Package 1 Length | 2.8 cm |
| Package 1 Weight | 5 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 0.7 cm |
| Package 2 Width | 2.4 cm |
| Package 2 Length | 30.5 cm |
| Package 2 Weight | 69 g |
| Unit Type of Package 3 | S01 |
| Number of Units in Package 3 | 500 |
| Package 3 Height | 15 cm |
| Package 3 Width | 15 cm |
| Package 3 Length | 40 cm |
| Package 3 Weight | 3.835 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 1 CO (Changeover) contact arrangement — all contacts independently switchable up to the contact voltage rating.
- Manufactured to IEC 60947-5-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What is the significance of the 6 A rating on the RSL1AB4ND?
A: The 6 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.
Q: What does the 1 CO (Changeover) contact configuration on the RSL1AB4ND mean?
A: CO (Change Over) contacts switch between two circuits — the common terminal connects to either NO or NC depending on the device state. Used for dual-purpose indication or reversing circuits.
Q: Can the RSL1AB4ND relay be mounted on a DIN rail socket for easy replacement?
A: This Schneider Electric relay typically requires direct panel or DIN rail wiring. For applications requiring frequent relay replacement, consider the plug-in relay variant of this series with a matching socket base.
Q: How do I test the RSL1AB4ND relay in the field without a signal source?
A: Most Schneider Electric relays can be manually forced using the test button (if fitted) — this mechanically closes the relay contacts without energising the coil, allowing functional testing of the controlled circuit. For coil testing, use a multimeter to measure coil resistance (typically 500–2000Ω for AC coils at rated voltage) and compare with datasheet values.