A9N19632 | Acti 9 – earth leakage circuit breaker – DPN Vigi – 1P + N – 10A – 30mA – Schneider Electric
₹22,260.00 Excl. GST
Dispatch By : 3 Weeks
Dispatch By : 3 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
A9N26946 | MX Shunt Trip MX plus 1 OF 220-415Vac dc – Schneider Electric
A9N26476 | DECLENCHEUR MX 415VAC 110-130VDC CCC – Schneider Electric
A9N26914 | Acti9 A9N OF bottom wiring 2-100mA aux – Schneider Electric
26970 | SET 2 LOCKING SLIDE – Schneider Electric
A9N26969 | VOLTAGE RELEASE MNX 220-240VAC DC GHOST – Schneider Electric
A9N26899 | Acti9 A9N OF+SD 24 VDC Ti24 term on top – Schneider Electric
A9MEM1560 | PowerTag Energy F63 1PN – Schneider Electric
A9N26500 | VOLTAGE RELEASE MSU 270VAC – Schneider Electric
A9N26960 | Voltage release MN 220-240Vac dc – Schneider Electric
A9N26478 | DECLENCHEUR MX 12-24VAC 12-24VDC CCC – Schneider Electric
A9N26948 | MX Shunt Trip MX plus 1 OF 24Vac dc – Schneider Electric
A9N27062 | Acti9 9 mm white spacer – Schneider Electric
The Schneider Electric A9N19632 is a rcbo from the Acti9 range, engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 10 A at 30 °C, 230 V AC, 1P + N. Buy the A9N19632 | Acti 9 – earth leakage circuit breaker – DPN Vigi – 1P + N – 10A – 30mA online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | A9N19632 |
| Category | RCBO |
| Main | |
| Circuit breaker application | Distribution |
| Range | Acti9 |
| Product or component type | Earth leakage circuit breaker |
| Product name | DPN Vigi |
| Device short name | DPN N Vigi |
| Poles description | 1P + N |
| Neutral position | Left |
| Number of protected poles | 1 |
| [In] rated current | 10 A at 30 °C |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Earth-leakage sensitivity | 30 mA |
| Earth-leakage protection time delay | Instantaneous |
| type | Type A-SI (Super Immunised) |
| Breaking capacity | 6000 A Icn at 230 V AC conforming to EN 61009 |
| Complementary | |
| Device location in system | Outgoer |
| [Ue] rated operational voltage | 230 V AC |
| Magnetic tripping limit | 5…10 x In |
| Residual current tripping technology | Voltage independent |
| [Ics] rated service breaking capacity | 6000 A at 230 V AC 50/60 Hz conforming to EN 61009 |
| Limitation class | 3 conforming to EN 61009 |
| [Ui] rated insulation voltage | 400 V AC conforming to EN 61009 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to EN 61009 |
| Contact position indicator | Yes |
| Control type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting support | DIN rail |
| 9 mm pitches | 4 |
| Product weight | 0.19 kg |
| Embedding depth | 72 mm |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles conforming to IEC 61009 |
| Connections – terminals | Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid |
| Earth-leakage protection | Integrated |
| Environment | |
| Standards | EN/IEC 61009-1 EN/IEC 61009-2-1 |
| Pollution degree | 3 conforming to EN 61009 |
| Overvoltage category | III |
| Tropicalisation | 2 conforming to EN 61009 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 2000 m |
| Ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…60 °C |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.500 cm |
| Package 1 Width | 4.000 cm |
| Package 1 Length | 10.000 cm |
| Package 1 Weight | 201.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 9.000 cm |
| Package 2 Width | 11.000 cm |
| Package 2 Length | 25.500 cm |
| Package 2 Weight | 1.302 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 54 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 12.242 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 10 A current rating with combined overload + short-circuit + earth-leakage protection in one device — complete circuit protection without a separate MCB and RCCB.
- 30 mA individual earth-leakage protection — an earth fault on this circuit trips only this RCBO; other circuits in the board remain energised, unlike a shared RCCB which disconnects all.
- 1 Pole + Neutral (1P+N) — designed for single-phase final circuits with switched neutral — both live and neutral disconnect on trip for full isolation.
- Single DIN rail module — same 17.5mm or 1P width as a standard MCB; maximises the number of protected circuits in a fixed enclosure size.
- Visi-Trip indicator — mid-position handle clearly shows which RCBO has tripped when multiple units are installed, speeding up fault identification.
- Manufactured to IEC 61009 / IS 12640-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What load can the A9N19632 protect at its rated 10 A?
A: The A9N19632 is rated to carry and protect circuits up to 10 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 10 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: Why is the 30 mA sensitivity specified on the A9N19632 and when should you choose a different rating?
A: 30 mA is the residual current at which the A9N19632 will trip within 300ms. A 30mA sensitivity provides additional shock protection (mandatory for socket circuits per IS 732). 100mA is used for fire protection (no shock protection). 300mA protects feeders without nuisance tripping. Choose based on the circuit’s risk profile — never use >30mA for socket outlet circuits in wet or high-risk locations.
Q: Which Schneider Electric accessories are compatible with the A9N19632?
A: The Schneider Electric A9N19632 series supports snap-on accessories including auxiliary contacts (OF), alarm contacts (SD), shunt trip coils (MX), undervoltage releases (MN), and comb busbars. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the A9N19632.
Q: What is the difference between an RCBO and a standard MCB — and why use the A9N19632?
A: A standard MCB protects against overload and short-circuit only. An RCBO combines MCB overcurrent/short-circuit protection AND RCCB earth leakage detection in a single 1-module device — ideal where both forms of protection are needed in limited panel space. Choose the A9N19632 when the application specifically requires rcbo characteristics.