The Schneider Electric A9N19647 is a rcbo from the Acti9 range, engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 32 A at 30 °C, 230 V AC, 1P + N. Buy the A9N19647 | Acti 9 – earth leakage circuit breaker – DPN Vigi – 1P + N – 32A – 300mA online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUA9N19647
CategoryRCBO
Main
Circuit breaker applicationDistribution
RangeActi9
Product or component typeEarth leakage circuit breaker
Product nameDPN Vigi
Device short nameDPN N Vigi
Poles description1P + N
Neutral positionLeft
Number of protected poles1
[In] rated current32 A at 30 °C
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity300 mA
Earth-leakage protection time delayInstantaneous
typeType A-SI (Super Immunised)
Breaking capacity6000 A Icn at 230 V AC conforming to EN 61009
Complementary
Device location in systemOutgoer
[Ue] rated operational voltage230 V AC
Magnetic tripping limit5…10 x In
Residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity6000 A at 230 V AC 50/60 Hz conforming to EN 61009
Limitation class3 conforming to EN 61009
[Ui] rated insulation voltage400 V AC conforming to EN 61009
[Uimp] rated impulse withstand voltage4 kV conforming to EN 61009
Contact position indicatorYes
Control typeToggle
Local signallingON/OFF indication
Mounting supportDIN rail
9 mm pitches4
Product weight0.19 kg
Embedding depth72 mm
ColourWhite
Mechanical durability20000 cycles
Electrical durability10000 cycles conforming to IEC 61009
Connections – terminalsTunnel type terminals1 cable(s) 10 mm² flexible
Tunnel type terminals1 cable(s) 16 mm² rigid
Earth-leakage protectionIntegrated
Environment
StandardsEN/IEC 61009-2-1
EN/IEC 61009-1
Pollution degree3 conforming to EN 61009
Overvoltage categoryIII
Tropicalisation2 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-40…60 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.5 cm
Package 1 Width3.6 cm
Package 1 Length8.5 cm
Package 1 Weight208 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.673 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight105.384 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 32 A current rating with combined overload + short-circuit + earth-leakage protection in one device — complete circuit protection without a separate MCB and RCCB.
  • 300 mA individual earth-leakage protection — an earth fault on this circuit trips only this RCBO; other circuits in the board remain energised, unlike a shared RCCB which disconnects all.
  • 1 Pole + Neutral (1P+N) — designed for single-phase final circuits with switched neutral — both live and neutral disconnect on trip for full isolation.
  • Single DIN rail module — same 17.5mm or 1P width as a standard MCB; maximises the number of protected circuits in a fixed enclosure size.
  • Visi-Trip indicator — mid-position handle clearly shows which RCBO has tripped when multiple units are installed, speeding up fault identification.
  • Manufactured to IEC 61009 / IS 12640-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

26970A9N27062A9N26914A9N26946A9N26899A9N26476A9N26948A9N26969A9N26960A9N26500A9N26478A9N26947A9N26961A9N26477A9MEM1560

❓ Frequently Asked Questions

Q: What load can the A9N19647 protect at its rated 32 A?

A: The A9N19647 is rated to carry and protect circuits up to 32 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 32 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: Why is the 300 mA sensitivity specified on the A9N19647 and when should you choose a different rating?

A: 300 mA is the residual current at which the A9N19647 will trip within 300ms. A 30mA sensitivity provides additional shock protection (mandatory for socket circuits per IS 732). 100mA is used for fire protection (no shock protection). 300mA protects feeders without nuisance tripping. Choose based on the circuit’s risk profile — never use >30mA for socket outlet circuits in wet or high-risk locations.

Q: Which Schneider Electric accessories are compatible with the A9N19647?

A: The Schneider Electric A9N19647 series supports snap-on accessories including auxiliary contacts (OF), alarm contacts (SD), shunt trip coils (MX), undervoltage releases (MN), and comb busbars. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the A9N19647.

Q: What is the difference between an RCBO and a standard MCB — and why use the A9N19647?

A: A standard MCB protects against overload and short-circuit only. An RCBO combines MCB overcurrent/short-circuit protection AND RCCB earth leakage detection in a single 1-module device — ideal where both forms of protection are needed in limited panel space. Choose the A9N19647 when the application specifically requires rcbo characteristics.

Customer Reviews