A9KF71310BQ | Acti 9 K60H 3P – 10 A – C curve 10 kA – set of 4 – Schneider Electric

SKU: A9KF71310BQ

Original price was: ₹6,323.00.Current price is: ₹4,489.33. Excl. GST

Dispatch By : 2 Weeks

Dispatch By : 2 Weeks

10 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The Schneider Electric A9KF71310BQ is a miniature circuit breaker (mcb) from the Acti9 range, engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 10 A, 415 V AC 50/60 Hz, 3P. Buy the A9KF71310BQ | Acti 9 K60H 3P – 10 A – C curve 10 kA – set of 4 online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUA9KF71310BQ
CategoryMiniature Circuit Breaker (MCB)
Main
RangeActi9
Product nameActi9 K60
Product or component typeMiniature circuit-breaker
Device short nameK60H
Device applicationDistribution
Poles description3P
Number of protected poles3
[In] rated current10 A
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Suitability for isolationYes conforming to EN/IEC 60898-1
StandardsEN/IEC 60898-1
Product certificationsISI
Complementary
Network frequency50/60 Hz
[Ue] rated operational voltage415 V AC 50/60 Hz
Magnetic tripping limit5…10 x In
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
[Ics] rated service breaking capacity7500 A 75 % x Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorNo
Control typeToggle
Local signallingWithout
Mounting modeFixed
Mounting supportDIN rail
Comb busbar and distribution block compatibilityDownstream: biconnect
9 mm pitches6
Height81 mm
Width54 mm
Depth70 mm
Product weight0.36 kg
Quantity per setSet of 4
ColourWhite
Mechanical durability20000 cycles
Electrical durability20000 cycles
Connections – terminalsTunnel type terminals (downstream) , 1…25 mm², rigid
Tunnel type terminals (upstream) , 1…25 mm², rigid
Tunnel type terminals (downstream) , 1…16 mm², flexible
Tunnel type terminals (upstream) , 1…16 mm², flexible
Wire stripping length14 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionWithout
Environment
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree2
Overvoltage categoryII
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Operating altitude0…2000 m
Ambient air temperature for operation-5…55 °C
Ambient air temperature for storage-25…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.0 cm
Package 1 Width5.0 cm
Package 1 Length8.0 cm
Package 1 Weight1.26 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • Protects circuits at 10 A with 10 kA short-circuit breaking capacity — rated for light industrial and commercial distribution boards.
  • Curve C tripping characteristic — optimised for general-purpose and inductive loads (motors, mixed circuits) — trips magnetically at 5–10× rated current.
  • 3 Poles — protects a three-phase circuit without neutral; fits standard 35mm DIN rail in distribution boards.
  • Thermal-magnetic trip mechanism — bimetal element trips on sustained overload, instantaneous magnetic trip on short-circuit; two independent protection functions in one compact module.
  • Visi-Trip indicator — handle snaps to a clearly visible mid-position on trip, allowing instant fault identification without opening the panel door.
  • Compatible with Acti9 comb busbar (1P, 2P, 3P, 3P+N) — parallel wiring of multiple MCBs without individual cables, cutting panel wiring time significantly.
  • Manufactured to IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.

❓ Frequently Asked Questions

Q: What load can the A9KF71310BQ protect at its rated 10 A?

A: The A9KF71310BQ is rated to carry and protect circuits up to 10 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 10 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 10 kA breaking capacity on the A9KF71310BQ mean in practice?

A: Breaking capacity (10 kA) is the maximum prospective short-circuit current the A9KF71310BQ can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 10 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: Why is Curve C specified for the A9KF71310BQ and what loads is it optimised for?

A: Curve C on the A9KF71310BQ trips magnetically at 5–10× rated current, making it ideal for general-purpose circuits including fluorescent lamps, small motors, and mixed loads. Using the wrong curve can cause nuisance tripping (too sensitive) or inadequate protection (not sensitive enough). Always match the curve to the load’s inrush characteristics.

Q: What happens when the A9KF71310BQ trips — how do I identify and reset it?

A: When the A9KF71310BQ trips on fault, the handle moves to a midway position (between ON and OFF), distinctly visible from a distance. To reset: (1) identify and rectify the fault, (2) push the handle fully to OFF, (3) then switch back to ON. Never force-reset without investigating the fault cause.

Q: Is the A9KF71310BQ suitable for both single-phase and three-phase systems?

A: The A9KF71310BQ with 3 Poles can protect three-phase circuits. Each pole simultaneously interrupts one phase — ensuring all phases are de-energised on a fault.