The Schneider Electric A9KF71463BQ is a miniature circuit breaker (mcb) from the Acti9 range, engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 63 A, 415 V AC 50/60 Hz, 4P. Buy the A9KF71463BQ | Acti 9 K60H 4P – 63 A – C curve 10 kA – set of 3 online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | A9KF71463BQ |
| Category | Miniature Circuit Breaker (MCB) |
| Main | |
| Range | Acti9 |
| Product name | Acti9 K60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | K60H |
| Device application | Distribution |
| Poles description | 4P |
| Number of protected poles | 4 |
| [In] rated current | 63 A |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Suitability for isolation | Yes conforming to EN/IEC 60898-1 |
| Standards | EN/IEC 60898-1 |
| Product certifications | ISI |
| Complementary | |
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 415 V AC 50/60 Hz |
| Magnetic tripping limit | 5…10 x In |
| Breaking capacity | 10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| [Ics] rated service breaking capacity | 7500 A 75 % x Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| Limitation class | 3 conforming to EN/IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Contact position indicator | No |
| Control type | Toggle |
| Local signalling | Without |
| Mounting mode | Fixed |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Downstream: biconnect |
| 9 mm pitches | 8 |
| Height | 81 mm |
| Width | 72 mm |
| Depth | 70 mm |
| Product weight | 0.48 kg |
| Quantity per set | Set of 3 |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections – terminals | Tunnel type terminals (downstream) , 1…35 mm², rigid Tunnel type terminals (upstream) , 1…35 mm², rigid Tunnel type terminals (downstream) , 1…25 mm², flexible Tunnel type terminals (upstream) , 1…25 mm², flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| Earth-leakage protection | Without |
| Environment | |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Pollution degree | 2 |
| Overvoltage category | II |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0…2000 m |
| Ambient air temperature for operation | -5…55 °C |
| Ambient air temperature for storage | -25…85 °C |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.0 cm |
| Package 1 Width | 7.0 cm |
| Package 1 Length | 8.0 cm |
| Package 1 Weight | 1.494 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Protects circuits at 63 A with 10 kA short-circuit breaking capacity — rated for light industrial and commercial distribution boards.
- Curve C tripping characteristic — optimised for general-purpose and inductive loads (motors, mixed circuits) — trips magnetically at 5–10× rated current.
- 4 Poles — protects a three-phase four-wire circuit with switched neutral; fits standard 35mm DIN rail in distribution boards.
- Thermal-magnetic trip mechanism — bimetal element trips on sustained overload, instantaneous magnetic trip on short-circuit; two independent protection functions in one compact module.
- Visi-Trip indicator — handle snaps to a clearly visible mid-position on trip, allowing instant fault identification without opening the panel door.
- Compatible with Acti9 comb busbar (1P, 2P, 3P, 3P+N) — parallel wiring of multiple MCBs without individual cables, cutting panel wiring time significantly.
- Manufactured to IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What load can the A9KF71463BQ protect at its rated 63 A?
A: The A9KF71463BQ is rated to carry and protect circuits up to 63 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 63 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What does the 10 kA breaking capacity on the A9KF71463BQ mean in practice?
A: Breaking capacity (10 kA) is the maximum prospective short-circuit current the A9KF71463BQ can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 10 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Why is Curve C specified for the A9KF71463BQ and what loads is it optimised for?
A: Curve C on the A9KF71463BQ trips magnetically at 5–10× rated current, making it ideal for general-purpose circuits including fluorescent lamps, small motors, and mixed loads. Using the wrong curve can cause nuisance tripping (too sensitive) or inadequate protection (not sensitive enough). Always match the curve to the load’s inrush characteristics.
Q: Can the A9KF71463BQ be DIN rail mounted in any standard distribution board?
A: Yes. This Schneider Electric MCB uses the standard 35mm EN 60715 DIN rail and 17.5mm module width, making it compatible with all major brand distribution boards and enclosures. Terminal capacity accommodates both rigid and flexible conductors up to the rated cross-section.
Q: What happens when the A9KF71463BQ trips — how do I identify and reset it?
A: When the A9KF71463BQ trips on fault, the handle moves to a midway position (between ON and OFF), distinctly visible from a distance. To reset: (1) identify and rectify the fault, (2) push the handle fully to OFF, (3) then switch back to ON. Never force-reset without investigating the fault cause.