C25F42D250 Circuit breaker, ComPacT NSX250F, 36kA 415VAC, 4 poles, MicroLogic 2.2 trip unit 250A Schneider Electric c25w42d25
C16B42D160 | Circuit breaker, ComPacT NSX160B, 25kA/415VAC, 4 poles, MicroLogic 2.2 trip unit 160A - Schneider Electric Original price was: ₹65,490.00.Current price is: ₹32,745.00. Excl. GST
Back to products
C25N6TM250 Circuit breaker, ComPacT NSX250N, 50kA 415VAC, 4 poles 3D neutral not protected , TMD trip unit 250A Schneider Ele
C16B6TM160 | Circuit breaker, ComPacT NSX160B, 25kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 160A - Schneider Electric Original price was: ₹49,670.00.Current price is: ₹24,835.00. Excl. GST

C16B6TM125 | Circuit breaker, ComPacT NSX160B, 25kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 125A – Schneider Electric

SKU: C16B6TM125

Original price was: ₹45,580.00.Current price is: ₹21,878.40. Excl. GST

In stock

In stock

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: C16B6TM125

Same-day dispatch · GST invoice available

15 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the C16B6TM125 | Circuit breaker, ComPacT NSX160B, 25kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 125A? This genuine Schneider Electric mccb from the ComPacT range is built for reliable circuit protection and isolation, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 125 A at 40 °C, 690 V AC 50/60 Hz, 4P. Order part number C16B6TM125 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUC16B6TM125
CategoryMCCB
Main
RangeComPacT
Product nameComPacT NSX
Device short nameNSX160B
Product or component typeCircuit breaker
Device applicationDistribution
Poles description4P
Protected poles description3D
Neutral positionLeft
[In] rated current125 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeB 25 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service breaking capacity40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability40000 cycles
Electrical durability40000 cycles at 440 V In/2
20000 cycles at 440 V In
15000 cycles at 690 V In/2
7500 cycles at 690 V In
Power dissipation per pole10.78 W
Mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
Downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating125 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7…1 x In
Long-time protection delay adjustment type trFixed
[tr] long-time delay adjustment range120…400 s at 1.5 x In
15 s at 6 x Ir
Neutral protection settingNo protection (3D)
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range1250 A
Earth-leakage protectionWithout
Number of slots5 slot(s)
Width (W)140 mm
Height (H)161 mm
Depth (D)86 mm
Product weight2.6 kg
Environment
StandardsEN/IEC 60947-2
Overvoltage categoryIII
Electrical shock protection classClass II on front face
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.000 cm
Package 1 Width15.000 cm
Package 1 Length19.000 cm
Package 1 Weight2.339 kg
Unit Type of Package 2S03
Number of Units in Package 26
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight14.454 kg
Unit Type of Package 3P12
Number of Units in Package 348
Package 3 Height45.000 cm
Package 3 Width80.000 cm
Package 3 Length120.000 cm
Package 3 Weight127.632 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 160 A frame rating — handles the full rated current continuously; designed for feeder and sub-distribution protection where fault levels exceed MCB capability.
  • 25 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in industrial main distribution boards.
  • TMD (Thermal-Magnetic) trip unit — adjustable overload setting (Ir) from 0.7–1× In with fixed instantaneous magnetic trip; simple and reliable for standard feeder applications.
  • 4 Poles — three-phase + switched neutral (TN-S system) for full four-pole isolation per IEC 60364.
  • CompacT NSX form factor — 70mm wide per pole; designed for high-density LV switchboards with up to 3 units per standard 250mm busbar bay.
  • Rotary handle with padlocking points — LOTO compliant; handle locks in OFF position with up to 3 padlocks, preventing accidental energisation during maintenance.
  • Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LV429354TLV429518LV429516LV429329LV4294892945029452LV429387LV429388LV429407LV429408LV429337TLV429338TLV429434LV429290LV429454LV429513

❓ Frequently Asked Questions

Q: What load can the C16B6TM125 protect at its rated 160 A?

A: The C16B6TM125 is rated to carry and protect circuits up to 160 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 160 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 25 kA breaking capacity on the C16B6TM125 mean in practice?

A: Breaking capacity (25 kA) is the maximum prospective short-circuit current the C16B6TM125 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 25 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: Can the C16B6TM125 be motorised for remote switching and automation?

A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.

Q: What trip unit type does the C16B6TM125 use — thermal-magnetic or electronic?

A: The C16B6TM125 uses a thermal-magnetic TMD trip unit — thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.

Q: Is the C16B6TM125 suitable for use as a motor branch circuit protector (Type E coordination)?

A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.

Customer Reviews