LV510300 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 16 A rating thermal magnetic TM-D trip unit, 3P 3d – Schneider Electric
₹13,420.00 Original price was: ₹13,420.00.₹6,173.20Current price is: ₹6,173.20. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LV429403 | MN 60V DC UNDERVOLTAGE RELEASE – Schneider Electric
LV429407 | MN undervoltage release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 220 to 240 VAC 50/60 Hz, 208 to 277 VAC 60 Hz – Schneider Electric
LV429390 | MX 24V DC SHUNT RELEASE. – Schneider Electric
LV429338_IN | Extended rotary handle CVS100/160/250 – Schneider Electric
LV429414 | MN 250V DC UNDERVOLTAGE RELEASE – Schneider Electric
LV429383 | MX 60V DC SHUNT RELEASE – Schneider Electric
LV429388 | MX shunt trip release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 380 to 415 VAC 50/60 Hz, 440 to 480 VAC 60 Hz – Schneider Electric
LV429408 | MN 380-415V50/60HZ 440-480V60HZ UVR – Schneider Electric
LV429389 | MX 525V 50HZ 600V 60HZ SHUNT RELEASE – Schneider Electric
LV429411 | MN 30V DC UNDERVOLTAGE RELEASE – Schneider Electric
29450 | standard auxiliary contact, circuit breaker status OF-SD-SDE-SDV, 1 single contact – Schneider Electric
LV429338T | ROTARY HANDLE EXT 100-250 BLK. – Schneider Electric
LV429337T | ROTARY HANDLE DIR 100-250 BLK – Schneider Electric
LV429451 | SDE ADAPTER FOR TRIP UNIT NSX100-250 CI – Schneider Electric
LV429387 | MX shunt trip release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 220 to 240 VAC 50/60 Hz, 208 to 277 VAC 60 Hz – Schneider Electric
LV429391 | MX 30V DC SHUNT RELEASE – Schneider Electric
LV429393 | MX shunt trip release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 125 VDC – Schneider Electric
LV429344 | keylock adapter, Compact NSX and EasyPact CVS 100/160/250, PowerPact Multistandard H/J frames, locking for rotary handle – Schneider Electric
LV429404 | MN 24V 50/60HZ UNDERVOLTAGE RELEASE – Schneider Electric
LV429385 | MX 48V 50/60HZ SHUNT RELEASE – Schneider Electric
LV429382 | MX 12V DC SHUNT RELEASE – Schneider Electric
LV429392 | MX 48V DC SHUNT RELEASE – Schneider Electric
LV429413 | MN 125V DC UNDERVOLTAGE RELEASE – Schneider Electric
LV429405 | MN 48V 50/60HZ UNDERVOLTAGE RELEASE – Schneider Electric
LV429402 | MN 12V DC UNDERVOLTAGE RELEASE – Schneider Electric
LV429412 | MN 48V DC UNDERVOLTAGE RELEASE – Schneider Electric
LV429354 | MECHANICAL INTERLOCKING FOR TOGGLE – Schneider Electric
LV429409 | MN undervoltage release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 525 VAC 50 Hz, 600 VAC 60 Hz – Schneider Electric
LV431563 | connection accessories, Compact NSX 100/160/250, EasyPact CVS 100/160/250, spreaders, 45 mm pitch, flat connection, 3 poles – Schneider Electric
LV429410 | MN undervoltage release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 24 VDC – Schneider Electric
LV429394 | MX 250V DC SHUNT RELEASE – Schneider Electric
LV429386 | MX 110-130V 50/60HZ SHUNT RELEASE – Schneider Electric
LV429406 | MN 110-130V 50/60Hz UNDERVOLTAGE RELEASE – Schneider Electric
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Part Number / SKU | LV510300 |
| Category | MCCB |
| Current Rating | 16 A |
| Voltage Rating | 415V AC |
| Poles | 3 Poles |
| Breaking Capacity | 25 kA |
| Standard | IEC 60947-2 / IS 13947-2 |
| Certifications | BIS certified, CE marked, RoHS compliant |
⚡ Key Features
- 25 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in industrial main distribution boards.
- Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
- 3 Poles — three-phase feeder protection; neutral not switched (TN-C / IT systems).
- Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What load can the LV510300 protect at its rated 16 A?
A: The LV510300 is rated to carry and protect circuits up to 16 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 16 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What does the 25 kA breaking capacity on the LV510300 mean in practice?
A: Breaking capacity (25 kA) is the maximum prospective short-circuit current the LV510300 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 25 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Can the LV510300 be motorised for remote switching and automation?
A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.
Q: What trip unit type does the LV510300 use — thermal-magnetic or electronic?
A: The LV510300 uses a thermal-magnetic TMD trip unit — thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.
Q: Is the LV510300 suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.













Reviews