Sourced through authorised channels, the Schneider Electric LV510302 mccb from the EasyPact range delivers dependable performance for reliable circuit protection and isolation. Key ratings include 32 A at 40 °C, 415V AC, 3P. myelectric.in stocks the LV510302 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 32 A rating thermal magnetic TM-D trip unit, 3P 3d for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULV510302
CategoryMCCB
Main
RangeEasyPact
Range of productEasyPact CVS100…250
Product nameEasyPact CVS
Device short nameCVS100B
Product or component typeCircuit breaker
Device applicationDistribution
Poles description3P
Protected poles description3D
Earth leakage protection (Vigi add on)Without
[In] rated current32 A at 40 °C
Network typeAC
Utilisation categoryCategory A
[Icu] Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating32 A at 40 °C
Protection typeOverload protection (thermal)
Short-circuit protection (magnetic)
Complementary
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Breaking capacity codeB
[Ics] rated service breaking capacity15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability30000 cycles
Electrical durability12000 cycles 415 V In conforming to IEC 60947-2
Control typeToggle
Thermal protection adjustment range22.4…32 A
Long time pick-up adjustment type IrAdjustable
Long time pick-up adjustment range0.7…1 x In
Long time delay adjustment typeFixed
Instantaneous pick-up adjustment type IiFixed
Instantaneous pick-up adjustment range400 A
Contact position indicatorYes
Mounting supportBackplate
Mounting modeFixed
Upside connectionFront
Downside connectionFront
Connections – terminalsScrew connection
Connection pitch35 mm
Compatibility codeCVS100
Width105 mm
Depth86 mm
Height161 mm
Product weight1.5 kg
Environment
StandardsIEC 60947-2
EN 60947-2
Product certificationsIEC
GOST
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.500 cm
Package 1 Width14.000 cm
Package 1 Length19.000 cm
Package 1 Weight1.702 kg
Unit Type of Package 2S03
Number of Units in Package 28
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight14.036 kg
Unit Type of Package 3P12
Number of Units in Package 364
Package 3 Height45.000 cm
Package 3 Width80.000 cm
Package 3 Length120.000 cm
Package 3 Weight124.288 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 25 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in industrial main distribution boards.
  • Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
  • 3 Poles — three-phase feeder protection; neutral not switched (TN-C / IT systems).
  • Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LV429517LV429515LV43156329450LV429451

❓ Frequently Asked Questions

Q: What load can the LV510302 protect at its rated 32 A?

A: The LV510302 is rated to carry and protect circuits up to 32 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 32 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 25 kA breaking capacity on the LV510302 mean in practice?

A: Breaking capacity (25 kA) is the maximum prospective short-circuit current the LV510302 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 25 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: What trip unit type does the LV510302 use — thermal-magnetic or electronic?

A: The LV510302 uses a thermal-magnetic TMD trip unit — thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.

Q: Is the LV510302 suitable for use as a motor branch circuit protector (Type E coordination)?

A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.

Q: Can the LV510302 be motorised for remote switching and automation?

A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.