EZC100N3063 | circuit breaker Easypact EZC100N – TMD – 63 A – 3 poles 3d – Schneider Electric
₹9,170.00 Excl. GST
Out of stock
Out of stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Part Number / SKU | EZC100N3063 |
| Category | MCCB |
| Current Rating | 63 A |
| Poles | 3 Poles |
| Standard | IEC 60947-2 / IS 13947-2 |
| Certifications | BIS certified, CE marked, RoHS compliant |
⚡ Key Features
- TMD (Thermal-Magnetic) trip unit — adjustable overload setting (Ir) from 0.7–1× In with fixed instantaneous magnetic trip; simple and reliable for standard feeder applications.
- 3 Poles — three-phase feeder protection; neutral not switched (TN-C / IT systems).
- Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What load can the EZC100N3063 protect at its rated 63 A?
A: The EZC100N3063 is rated to carry and protect circuits up to 63 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 63 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: Can the EZC100N3063 be motorised for remote switching and automation?
A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.
Q: What trip unit type does the EZC100N3063 use — thermal-magnetic or electronic?
A: The EZC100N3063 uses a thermal-magnetic TMD trip unit — thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.
Q: Is the EZC100N3063 suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.
Q: What is the difference between an MCCB and a standard MCB — and why use the EZC100N3063?
A: A standard MCB protects against overload and short-circuit only. An MCCB handles much higher fault levels and larger current ratings — MCCBs are rated up to 1600A with 25–200kA breaking capacity, compared to MCBs which are capped at typically 125A and 10kA. Choose the EZC100N3063 when the application specifically requires mccb characteristics.













Reviews