EZC250F3150 circuit breaker Easypact EZC250F TMD 150 A 3 poles 3d Schneider Electric ezc250f3250 image 1500x1500
EZC250F3125 | circuit breaker Easypact EZC250F - TMD - 125 A - 3 poles 3d - Schneider Electric Original price was: ₹15,350.00.Current price is: ₹7,675.00. Excl. GST
Back to products
EZC250F3150 circuit breaker Easypact EZC250F TMD 150 A 3 poles 3d Schneider Electric ezc250f3250 image 1500x1500
EZC250F3160 | circuit breaker Easypact EZC250F - TMD - 160 A - 3 poles 3d - Schneider Electric Original price was: ₹17,520.00.Current price is: ₹8,760.00. Excl. GST

EZC250F3150 | circuit breaker Easypact EZC250F – TMD – 150 A – 3 poles 3d – Schneider Electric

SKU: EZC250F3150

Original price was: ₹15,470.00.Current price is: ₹7,735.00. Excl. GST

In stock

In stock

13 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the EZC250F3150 | circuit breaker Easypact EZC250F – TMD – 150 A – 3 poles 3d? This genuine Schneider Electric mccb from the EasyPact range is built for reliable circuit protection and isolation, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 150 A at 40 °C, 550 V AC 50/60 Hz, 3P. Order part number EZC250F3150 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUEZC250F3150
CategoryMCCB
Main
Range of productEasyPact
Product or component typeCircuit breaker
Device short nameEasypact EZC250F
Circuit breaker nameEasypact EZC250F
Device applicationDistribution
Poles description3P
Protected poles description3t
Network typeAC
DC
Network frequency50/60 Hz
[In] rated current150 A at 40 °C
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
[Ue] rated operational voltage550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
Breaking capacity codeF
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 125 V DC 1P conforming to IEC 60947-2
5 kA Icu at 250 V DC 2P conforming to IEC 60947-2
5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 125 V DC conforming to IEC 60947-2
2.5 kA at 250 V DC conforming to IEC 60947-2
2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
9 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating150 A at 50 °C
Protection typeOverload protection
Short-circuit protection
Pollution degree3 conforming to IEC 60664-1
3 conforming to IEC 947-1
Complementary
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Upside connectionFront
Downside connectionFront
Mechanical durability10000 cycles
Connection pitch35 mm
Local signallingPositive contact indication
Neutral protection settingWithout protection
Earth-leakage protectionWithout
Height165 mm
Width105 mm
Depth60 mm
Environment
StandardsGB/T 14048.2
EN/IEC 60947-2
EN/IEC 60947-1
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-35…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.400 cm
Package 1 Width11.300 cm
Package 1 Length18.000 cm
Package 1 Weight1.640 kg
Unit Type of Package 2S03
Number of Units in Package 28
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight13.607 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • TMD (Thermal-Magnetic) trip unit — adjustable overload setting (Ir) from 0.7–1× In with fixed instantaneous magnetic trip; simple and reliable for standard feeder applications.
  • 3 Poles — three-phase feeder protection; neutral not switched (TN-C / IT systems).
  • Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

EZEROTEEZEROTDSEZETSHD3PEZESPDR3PEZESHT200ACEZEAXEZEAXALEZEUVR200ACEZEAL

❓ Frequently Asked Questions

Q: What load can the EZC250F3150 protect at its rated 150 A?

A: The EZC250F3150 is rated to carry and protect circuits up to 150 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 150 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: Can the EZC250F3150 be motorised for remote switching and automation?

A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.

Q: What trip unit type does the EZC250F3150 use — thermal-magnetic or electronic?

A: The EZC250F3150 uses a thermal-magnetic TMD trip unit — thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.

Q: Is the EZC250F3150 suitable for use as a motor branch circuit protector (Type E coordination)?

A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.

Q: What is the difference between an MCCB and a standard MCB — and why use the EZC250F3150?

A: A standard MCB protects against overload and short-circuit only. An MCCB handles much higher fault levels and larger current ratings — MCCBs are rated up to 1600A with 25–200kA breaking capacity, compared to MCBs which are capped at typically 125A and 10kA. Choose the EZC250F3150 when the application specifically requires mccb characteristics.