Sourced through authorised channels, the Schneider Electric ZB2BE102C contactor accessory from the Harmony XB2 range delivers dependable performance for motor control and switching. Key ratings include 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1. myelectric.in stocks the ZB2BE102C | contact block ZB2 – 1 NC contact – spring return for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | ZB2BE102C |
| Category | Contactor Accessory |
| Main | |
| Range of product | Harmony XB2 |
| Product or component type | Complete body/contact assembly |
| Component name | ZB2 |
| Electrical circuit type | Control circuit |
| Contact block application | Single speed |
| Contact block type | Single |
| Product compatibility | ZB2..C |
| Contacts type and composition | 1 NC |
| Mounting of block | Front mounting |
| Sale per indivisible quantity | 1 |
| Device short name | XB2 |
| Device presentation | Basic element |
| Body type | Body for control button |
| Contact operation | Slow-break |
| Complementary | |
| Mechanical durability | 3000000 cycles |
| Contact code designation | A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 947-5-1 appendix A A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 947-5-1 appendix A Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 947-5-1 appendix A Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 947-5-1 appendix A |
| [Ithe] conventional enclosed thermal current | 10 A |
| [Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| Maximum resistance across terminals | 25 MOhm |
| Operating force | 3…5 N |
| Short-circuit protection | 10 A fuse protection by cartridge fuse type gG (gl) |
| Rated operational power in W | 40 W DC-13 for 1000000 cycles, operating rate <3600 cyc/h at 120 V, load factor = 0.5 conforming to IEC 60947-5-1 48 W DC-13 for 1000000 cycles, operating rate <3600 cyc/h at 48 V, load factor = 0.5 conforming to IEC 60947-5-1 65 W DC-13 for 1000000 cycles, operating rate <3600 cyc/h at 24 V, load factor = 0.5 conforming to IEC 60947-5-1 |
| Terminals description ISO n°1 | (11-12)NC |
| Product weight | 0.015 kg |
| Height | 29 mm |
| Width | 15 mm |
| Depth | 24 mm |
| Connections – terminals | Screw clamps terminals |
| Fixing collar material | Zamak |
| Connections – terminals | Screw clamps terminals, 1 x 2.5 mm² with or without cable end Screw clamps terminals, 2 x 1.5 mm² with or without cable end |
| Contacts material | Silver alloy (Ag/Ni) |
| Contacts usage | Standard contacts |
| Connections – terminals | Screw clamp terminal, <= 2 x 1.5 mm² with and without cable ends Screw clamp terminal, <= 1 x 2.5 mm² with and without cable ends Screw clamp terminal, >= 1 x 0.5 mm² with and without cable ends Faston terminals, connection size: 6.3 mm |
| Electrical durability | 1000000 cycles, AC-15, 3 A at 240 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.27 A at 250 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
| Electrical reliability | Λ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to IEC 60947-5-4 Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to IEC 60947-5-4 |
| [Ie] rated operational current | 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 |
| Short-circuit protection | 10 A gL fuse type gG conforming to IEC 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A conforming to IEC 60947-5-1 |
| Positive opening | With conforming to IEC 60947-5-1 appendix K |
| Operating travel | 1.5 mm (NO changing electrical state) 5 mm (total travel) |
| Shape of screw head | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver |
| Protective treatment | TC/TH |
| Customizable | No |
| Shock resistance | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
| Tightening torque | 0.8…1.0 N.m |
| Fixing mode | Fixing screw beneath head recommended torque: 0.8 N.m Fixing screw beneath head recommended torque: 1.0 N.m |
| Environment | |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…70 °C |
| Vibration resistance | 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6 |
| Electrical shock protection class | Class II conforming to IEC 61140 |
| Product certifications | CE CCC |
| Standards | IEC 60947-1 IEC 60947-5-1 IEC 60947-5-4 GB/T 14048.1 GB/T 14048.5 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1.500 cm |
| Package 1 Width | 2.790 cm |
| Package 1 Length | 2.870 cm |
| Package 1 Weight | 16.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 150 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 2.543 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 2400 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 49.188 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Genuine Schneider Electric OEM accessory — manufactured to the same specification and tested to the same standards as the parent device; ensures mechanical and electrical compatibility that third-party alternatives cannot guarantee.
- Auxiliary contact block (OF type) — 1 NC (Normally Closed) contacts mirror the main contact position; wired to PLC for run/trip feedback, indicator lamps, or interlocking with upstream devices.
- 1 NC (Normally Closed) contact arrangement — extends the switching capacity of the parent device for PLC feedback, interlocking, or additional signalling circuits.
- Direct clip-on or screw-mount to parent device — fits without panel modification or additional wiring between the accessory and main device; field-retrofittable.
- Manufactured to IEC 60947 (tested as part of the parent device certification) — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What does the 1 NC (Normally Closed) contact configuration on the ZB2BE102C mean?
A: These contacts change state when the device is operated or energised. Size the contact for the actual switched load — pilot duty ratings are typically lower than the main contact rating.