Looking for the METSEEM6400NGRSCL5 | Conzerv Power and Energy meter – inst., pulse, RS485, THD, 15th Har, Class 0.5S? This genuine Schneider Electric panel meter from the EasyLogic range is built for accurate electrical measurement and monitoring, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 5 A, IP51 front:. Order part number METSEEM6400NGRSCL5 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | METSEEM6400NGRSCL5 |
| Category | Panel Meter |
| Main | |
| Range | EasyLogic |
| Product name | EM6400NG+ RS-485 |
| Product or component type | Energy meter |
| Complementary | |
| Power quality analysis | up to the 15th harmonic |
| Device application | Power monitoring |
| Type of measurement | Current Voltage Frequency Apparent energy Apparent power Active and reactive energy Active and reactive power |
| Metering type | Average current Iavg Average voltage Vavg Demand current I1, I2, I3 Phase currents Voltage U21, U32, U13, V1, V2, V3 Apparent power S, S1, S2, S3 Unbalance current Active, reactive, apparent energy (signed, four quadrant) Demand power P, Q, S Peak demand currents Calculated neutral current Peak demand power PM, QM, SM Reactive power Q, Q1, Q2, Q3 Unbalance voltage Power factor and displacement PF (signed, four quadrant) Active power P, P1, P2, P3 |
| [Us] rated supply voltage | 40…300 V AC 45…65 Hz 40…300 V DC |
| Network frequency | 60 Hz 50 Hz |
| [In] rated current | 5 A 1 A |
| type of network | 1P + N 3P + N 2P + N 2P 3P |
| Maximum power consumption in VA | 6 VA at 277 V between phase and neutral |
| Maximum power consumption in W | 2 W at 277 V |
| Display type | 7 segments LED |
| Display colour | Red |
| Messages display capacity | 3 fields of 4 characters |
| Display digits | 12 digit(s) – 14.2 mm in height |
| Communication of data | Net energy Reading of time-stamped measurements and events Total energy Energy metering |
| Tamperproof of settings | Protected by access code |
| Sampling rate | 64 samples/cycle |
| Measurement current | 5…6000 mA |
| Signal | Current 0…12 A (impedance 0.3 MOhm)6 x Voltage (impedance 5 MOhm)4 x |
| Measurement voltage | 35…480 V AC 45…65 Hz between phases 35…277 V AC 45…65 Hz between phase and neutral 35…600 V AC 45…65 Hz between phases 35…347 V AC 45…65 Hz between phase and neutral 600…999000 V AC 45…65 Hz with external VT |
| Frequency measurement range | 45…65 Hz |
| Measurement accuracy | Current +/- 0.5 % Voltage +/- 0.5 % Power +/- 0.5 % Frequency +/- 0.05 % Power factor +/- 0.01 |
| Accuracy class | Class 1 active energy conforming to IEC 62053-21 Class 2 reactive energy conforming to IEC 62053-23 Class 5P harmonic distortion (I THD & U THD) conforming to IEC 61557-12 Class 5P individual harmonics up to the 15th conforming to IEC 61557-12 |
| Number of outputs | 0 |
| Demand intervals | Configurable from 1 to 60 min |
| Information displayed | Voltage (min/max) Current (min/max) Power factor (min/max) Frequency (min/max) Active power (min/max) Apparent power (min/max) Reactive power (min/max) Time (min/max) Demand current (past value) Demand current (present value) Demand power (past value) Demand power (present value) |
| Local signalling | Green LED: activity Red LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh) Green LED: communication status |
| Communication port protocol | Modbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V |
| Communication port support | RS485 |
| Data recording | Time stamping Energy consumption logs Min/max of instantaneous values |
| Material | Polycarbonate |
| Flame retardance | V-0 conforming to UL 94 |
| Mounting mode | Panel-mounted Flush-mounted |
| Mounting support | Framework |
| fixing mode | By clamp |
| Installation category | III |
| Type of installation | Indoor installation |
| Measurement category | Category III 480 V Category II 480…600 V |
| Electrical insulation class | Class II |
| Connections – terminals | Current circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s) Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) Communication: screw clamp terminals 0.33…3.31 mm² cable(s) |
| Tightening torque | Current circuit: 0.9…1 N.m Philips No 2 screwdriver Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver Control circuit: 0.9…1 N.m Philips No 2 screwdriver Communication: 0.9…1 N.m Philips No 2 screwdriver |
| Wire stripping length | Current circuit: 3.68 mm Voltage circuit: 7 mm Control circuit: 7 mm Communication: 7 mm |
| Standards | IEC 61010-1:ed. 3 UL 61010-1:ed. 3 |
| Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 C-Tick |
| Width | 96 mm |
| Depth | Panel : 73 mm Outside : 13 mm |
| Height | 96 mm |
| Product weight | 600 g |
| Environment | |
| Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A |
| Overvoltage category | III |
| IP degree of protection | IP51 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529 |
| Relative humidity | 5…95 % at 50 °C |
| Pollution degree | 2 |
| Ambient air temperature for operation | -10…60 °C |
| Ambient air temperature for storage | -20…70 °C |
| Operating altitude | <= 2000 m |
| service life | 7 year(s) |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 10.6 cm |
| Package 1 Width | 11.8 cm |
| Package 1 Length | 13 cm |
| Package 1 Weight | 480 g |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.













Reviews
Clear filtersThere are no reviews yet.