LAEN20 | EasyPact TVS – auxiliary contact block – 2 NO – screw-clamps terminals – Schneider Electric
₹720.00 Original price was: ₹720.00.₹302.40Current price is: ₹302.40. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LC1E2510M7 | Easy TeSys contactor 3P(3 NO) – AC-3 – <= 440 V 25A - 220 V AC coil - Schneider Electric
LC1E0910M5 | 3P CONTACTOR EasyPact TVS 1NO 4KW 400V – Schneider Electric
LC1E1810M5 | 3P Contactor Easypact Tvs 1No 7,5Kw – Schneider Electric
LC1E0910M7 | Easy TeSys contactor 3P(3 NO) – AC-3 – <= 440 V 9A - 220 V AC coil - Schneider Electric
LC1E1810M7 | Easy TeSys contactor 3P(3 NO) – AC-3 – <= 440 V 18A - 220 V AC coil - Schneider Electric
Sourced through authorised channels, the Schneider Electric LAEN20 circuit breaker accessory from the Easy TeSys range delivers dependable performance for reliable circuit protection and isolation. Key ratings include <= 690 V, IP20. myelectric.in stocks the LAEN20 | EasyPact TVS - auxiliary contact block - 2 NO - screw-clamps terminals for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LAEN20 |
| Category | Circuit Breaker Accessory |
| Main | |
| Range | Easy TeSys |
| Range of product | Easy TeSys Control |
| Product or component type | Auxiliary contact block |
| Device application | Signalling |
| Device short name | LAEN |
| Mounting location | Front |
| Auxiliary contacts operation | Instantaneous |
| Complementary | |
| Range compatibility | EasyPact EasyPact TVS LC1E |
| Pole contact composition | 2 NO |
| [Ui] rated insulation voltage | 690 V – for control circuit conforming to IEC 60947-5-1 |
| [Ue] rated operational voltage | <= 690 V |
| [Ith] conventional free air thermal current | 8 A (at 60 °C) |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1 |
| [Icw] rated short-time withstand current | 100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
| Protection type | GG fuse 10 A |
| Mechanical durability | 10 Mcycles |
| Minimum switching current | 5 mA |
| minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on energisation no overlap between NC and NO contact 1.5 ms on de-energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections – terminals | Control circuit: screw clamp terminals 1 1 mm² – external diameter: 6 mm – cable stiffness: solid or flexible with cable end Control circuit: screw clamp terminals 1 1 mm² – external diameter: 6 mm – cable stiffness: solid or flexible without cable end Control circuit: screw clamp terminals 2 2.5 mm² – external diameter: 6 mm – cable stiffness: solid or flexible with cable end Control circuit: screw clamp terminals 2 2.5 mm² – external diameter: 6 mm – cable stiffness: solid or flexible without cable end |
| Product weight | 0.035 kg |
| Colour | Grey (RAL 7011) |
| Environment | |
| Standards | EN/IEC 60947-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ |
| Product certifications | CB Scheme CCC CE EAC |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -5…55 °C |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 3000 m without derating |
| Environmental characteristic | Standard environment |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3 cm |
| Package 1 Width | 7.4 cm |
| Package 1 Length | 13 cm |
| Package 1 Weight | 50 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 100 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 3.8 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Genuine Schneider Electric OEM accessory — manufactured to the same specification and tested to the same standards as the parent device; ensures mechanical and electrical compatibility that third-party alternatives cannot guarantee.
- Auxiliary contact block (OF type) — 2 NO (Normally Open) contacts mirror the main contact position; wired to PLC for run/trip feedback, indicator lamps, or interlocking with upstream devices.
- 2 NO (Normally Open) contact arrangement — extends the switching capacity of the parent device for PLC feedback, interlocking, or additional signalling circuits.
- Direct clip-on or screw-mount to parent device — fits without panel modification or additional wiring between the accessory and main device; field-retrofittable.
- Manufactured to IEC 60947 (tested as part of the parent device certification) — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What does the 2 NO (Normally Open) contact configuration on the LAEN20 mean?
A: These contacts change state when the device is operated or energised. Size the contact for the actual switched load — pilot duty ratings are typically lower than the main contact rating.