LC1G150KUEN | High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 150A, standard version, 100…250V wide band AC/DC coil - Schneider Electric

SKU: LC1G150KUEN

Original price was: ₹66,890.00.Current price is: ₹33,445.00. Excl. GST

In stock

In stock

20 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LC1G150KUEN | High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 150A, standard version, 100…250V wide band AC/DC coil? This genuine Schneider Electric contactor from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 275 A, <= 1000 V AC 50/60 Hz, 3P. Order part number LC1G150KUEN from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULC1G150KUEN
CategoryContactor
Main
RangeTeSys
Range of productTeSys Giga
Product or component typeContactor
Device short nameLC1G
Contactor applicationPower switching
Motor control
Utilisation categoryAC-1
AC-3
AC-3e
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8a
AC-8b
DC-1
DC-3
DC-5
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current275 A (at <40 °C) at <= 1000 V AC-1
150 A (at <60 °C) at <= 440 V AC-3
[Uc] control circuit voltage100…250 V AC 50/60 Hz
100…250 V DC
Control circuit voltage limitsOperational: 0.8 Uc Min…1.1 Uc Max (at <60 °C)
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <60 °C)
Complementary
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current275 A (at 40 °C)
Rated breaking capacity1280 A at 440 V
[Icw] rated short-time withstand current1.2 kA – 10 s
0.7 kA – 30 s
0.6 kA – 1 min
0.45 kA – 3 min
0.35 kA – 10 min
Associated fuse rating160 A aM at <= 440 V for motor
160 A aM at <= 690 V for motor
315 A gG at <= 690 V
300 A UL Type J at <= 600 V
Average impedance0.00018 Ohm
[Ui] rated insulation voltage1000 V
Power dissipation per pole10 W AC-1 – Ith 275 A
5 W AC-3 – Ith 150 A
Compatibility codeLC1G
Pole contact composition3 NO
Auxiliary contact composition1 NO + 1 NC
Motor power kW37 kW at 230 V AC 50/60 Hz (AC-3e)
75 kW at 400 V AC 50/60 Hz (AC-3e)
75 kW at 415 V AC 50/60 Hz (AC-3e)
90 kW at 440 V AC 50/60 Hz (AC-3e)
90 kW at 500 V AC 50/60 Hz (AC-3e)
90 kW at 690 V AC 50/60 Hz (AC-3e)
75 kW at 1000 V AC 50/60 Hz (AC-3e)
37 kW at 230 V AC 50/60 Hz (AC-3)
75 kW at 400 V AC 50/60 Hz (AC-3)
75 kW at 415 V AC 50/60 Hz (AC-3)
90 kW at 440 V AC 50/60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
90 kW at 690 V AC 50/60 Hz (AC-3)
75 kW at 1000 V AC 50/60 Hz (AC-3)
37 kW at 230 V AC 50/60 Hz (AC-4)
75 kW at 400 V AC 50/60 Hz (AC-4)
75 kW at 415 V AC 50/60 Hz (AC-4)
80 kW at 440 V AC 50/60 Hz (AC-4)
90 kW at 500 V AC 50/60 Hz (AC-4)
90 kW at 690 V AC 50/60 Hz (AC-4)
75 kW at 1000 V AC 50/60 Hz (AC-4)
Motor power hp40 hp at 200/208 V 60 Hz
50 hp at 230/240 V 60 Hz
100 hp at 460/480 V 60 Hz
125 hp at 575/600 V 60 Hz
Irms rated making capacity1890 A at 440 V
Coil technologyBuilt-in bidirectional peak limiting
Safety reliability levelB10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability8 Mcycles
inrush power in VA (50/60 Hz, AC)540 VA
inrush power in W (DC)380 W
hold-in power consumption in VA (50/60 Hz, AC)12.4 VA
hold-in power consumption in W (DC)7.8 W
Operating time40…70 ms closing
15…50 ms opening
Maximum operating rate600 cyc/h AC-3
600 cyc/h AC-3e
300 cyc/h AC-1
150 cyc/h AC-4
Connections – terminalsPower circuit: bar 2 – busbar cross section: 25 x 6 mm
Power circuit: lugs-ring terminals 1 185 mm²
Power circuit: bolted connection
Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: flexible with cable end
Connection pitch35 mm
Mounting supportPlate
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-1
UL 60335-2-40:Annex JJ
Product certificationsCB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL
Tightening torque18 N.m
Height193 mm
Width108 mm
Depth193 mm
Product weight3.5 kg
Environment
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-60…80 °C
Mechanical robustnessVibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
ColourDark grey
Protective treatmentTH
Permissible ambient air temperature around the device-40…70 °C at Uc
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height25.000 cm
Package 1 Width23.000 cm
Package 1 Length38.500 cm
Package 1 Weight4.827 kg
Unit Type of Package 2P06
Number of Units in Package 28
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight45.500 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 150 A AC-3 rated — suits up to a 75 kW squirrel-cage induction motor at 415V for direct-on-line (DOL) starting and running.
  • 3 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
  • Main contacts rated up to 440V AC — compatible with 415V AC three-phase Indian supply and 480V AC North American systems.
  • Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LA9G970LA9G971LA9G3101LA9GRFB1LA9G3801LA9G3701LA9G3760LA9G3750LA9GQQ330LAG8N113PLAG8N113LAG8N203PLAG8N203LX1G3QKUENLA9G3QA

❓ Frequently Asked Questions

Q: Is the LC1G150KUEN rated 150 A for AC-3 motor duty or AC-1 resistive duty?

A: The 150 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.

Q: What circuit can the 3 NO (Normally Open) contacts of the LC1G150KUEN switch at 440V AC?

A: The 3 NO (Normally Open) contacts on the LC1G150KUEN are rated for switching at up to 440V AC. These auxiliary contacts are typically used for: (1) indication lamps and buzzers, (2) PLC input feedback to confirm device state, (3) interlocking with other contactors or relays in control circuits. Check the current rating of the auxiliary contact (typically 10A at 250V AC) — do not use for power load switching.

Q: Can multiple LC1G150KUEN contactors be wired for star-delta starting?

A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.

Q: What is the electrical and mechanical life of the LC1G150KUEN?

A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.

Q: Can the LC1G150KUEN be used for reversing duty (forward/reverse motor control)?

A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.

Customer Reviews