LC1G400KUEN | High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 400A, standard version, 100…250V wide band AC/DC coil - Schneider Electric
₹160,225.00 Original price was: ₹160,225.00.₹80,112.50Current price is: ₹80,112.50. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LAG8N113 | AUX contact 1NO+1NC push-in terminals – Schneider Electric
LA9G970 | Mechanical Interlock, for TeSys Giga contactor LC1G115-500, IP20 – Schneider Electric
LAG8N203P | AUX contact 2NO push-in type L1/R1 – Schneider Electric
LAG8N113P | AUX contact 1NO+1NC push-in type L1/R1 – Schneider Electric
Looking for the LC1G400KUEN | High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 400A, standard version, 100…250V wide band AC/DC coil? This genuine Schneider Electric contactor from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 550 A, <= 1000 V AC 50/60 Hz, 3P. Order part number LC1G400KUEN from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LC1G400KUEN |
| Category | Contactor |
| Main | |
| Range | TeSys |
| Range of product | TeSys Giga |
| Product or component type | Contactor |
| Device short name | LC1G |
| Contactor application | Power switching Motor control |
| Utilisation category | AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5 |
| Poles description | 3P |
| [Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
| [Ie] rated operational current | 550 A (at <40 °C) at <= 1000 V AC-1 400 A (at <60 °C) at <= 440 V AC-3 |
| [Uc] control circuit voltage | 100…250 V AC 50/60 Hz 100…250 V DC |
| Control circuit voltage limits | Operational: 0.8 Uc Min…1.1 Uc Max (at <60 °C) Drop-out: 0.1 Uc Max…0.45 Uc Min (at <60 °C) |
| Complementary | |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 550 A (at 40 °C) |
| Rated breaking capacity | 3480 A at 440 V |
| [Icw] rated short-time withstand current | 3.6 kA – 10 s 2.4 kA – 30 s 1.7 kA – 1 min 1.2 kA – 3 min 1.0 kA – 10 min |
| Associated fuse rating | 500 A aM at <= 440 V for motor 315 A aM at <= 690 V for motor 630 A gG at <= 690 V 600 A UL Type L at <= 600 V |
| Average impedance | 0.0001 Ohm |
| [Ui] rated insulation voltage | 1000 V |
| Power dissipation per pole | 30 W AC-1 – Ith 550 A 16 W AC-3 – Ith 400 A |
| Compatibility code | LC1G |
| Pole contact composition | 3 NO |
| Auxiliary contact composition | 1 NO + 1 NC |
| Motor power kW | 110 kW at 230 V AC 50/60 Hz (AC-3e) 200 kW at 400 V AC 50/60 Hz (AC-3e) 200 kW at 415 V AC 50/60 Hz (AC-3e) 250 kW at 440 V AC 50/60 Hz (AC-3e) 250 kW at 500 V AC 50/60 Hz (AC-3e) 315 kW at 690 V AC 50/60 Hz (AC-3e) 220 kW at 1000 V AC 50/60 Hz (AC-3e) 110 kW at 230 V AC 50/60 Hz (AC-3) 200 kW at 400 V AC 50/60 Hz (AC-3) 200 kW at 415 V AC 50/60 Hz (AC-3) 250 kW at 440 V AC 50/60 Hz (AC-3) 250 kW at 500 V AC 50/60 Hz (AC-3) 315 kW at 690 V AC 50/60 Hz (AC-3) 220 kW at 1000 V AC 50/60 Hz (AC-3) 110 kW at 230 V AC 50/60 Hz (AC-4) 200 kW at 400 V AC 50/60 Hz (AC-4) 200 kW at 415 V AC 50/60 Hz (AC-4) 220 kW at 440 V AC 50/60 Hz (AC-4) 250 kW at 500 V AC 50/60 Hz (AC-4) 315 kW at 690 V AC 50/60 Hz (AC-4) 220 kW at 1000 V AC 50/60 Hz (AC-4) |
| Motor power hp | 125 hp at 200/208 V 60 Hz 150 hp at 230/240 V 60 Hz 300 hp at 460/480 V 60 Hz 400 hp at 575/600 V 60 Hz |
| Irms rated making capacity | 5090 A at 440 V |
| Coil technology | Built-in bidirectional peak limiting |
| Safety reliability level | B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 8 Mcycles |
| inrush power in VA (50/60 Hz, AC) | 750 VA |
| inrush power in W (DC) | 660 W |
| hold-in power consumption in VA (50/60 Hz, AC) | 15.5 VA |
| hold-in power consumption in W (DC) | 9.3 W |
| Operating time | 40…70 ms closing 15…50 ms opening |
| Maximum operating rate | 600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4 |
| Connections – terminals | Power circuit: bar 2 – busbar cross section: 32 x 10 mm Power circuit: lugs-ring terminals 1 185 mm² Power circuit: bolted connection Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end Control circuit: push-in 2 0.5…1.0 mm² with cable end Control circuit: push-in 0.75…2.5 mm² – cable stiffness: solid stranded without cable end Control circuit: push-in 0.75…2.5 mm² – cable stiffness: flexible with cable end |
| Connection pitch | 45 mm |
| Mounting support | Plate |
| Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme CCC cULus EAC CE UKCA EU-RO-MR by DNV-GL |
| Tightening torque | 35 N.m |
| Height | 225 mm |
| Width | 140 mm |
| Depth | 226 mm |
| Product weight | 7 kg |
| Environment | |
| IP degree of protection | IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106 |
| Ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -60…80 °C |
| Mechanical robustness | Vibrations 5…300 Hz 2 gn contactor open Vibrations 5…300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed |
| Colour | Dark grey |
| Protective treatment | TH |
| Permissible ambient air temperature around the device | -40…70 °C at Uc |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 30.5 cm |
| Package 1 Width | 23 cm |
| Package 1 Length | 36.8 cm |
| Package 1 Weight | 8.235 kg |
| Unit Type of Package 2 | P06 |
| Number of Units in Package 2 | 8 |
| Package 2 Height | 75 cm |
| Package 2 Width | 60 cm |
| Package 2 Length | 80 cm |
| Package 2 Weight | 74.38 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 400 A AC-3 rated for motor and resistive load switching at LV.
- 3 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
- Main contacts rated up to 440V AC — compatible with 415V AC three-phase Indian supply and 480V AC North American systems.
- Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: Is the LC1G400KUEN rated 400 A for AC-3 motor duty or AC-1 resistive duty?
A: The 400 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.
Q: What circuit can the 3 NO (Normally Open) contacts of the LC1G400KUEN switch at 440V AC?
A: The 3 NO (Normally Open) contacts on the LC1G400KUEN are rated for switching at up to 440V AC. These auxiliary contacts are typically used for: (1) indication lamps and buzzers, (2) PLC input feedback to confirm device state, (3) interlocking with other contactors or relays in control circuits. Check the current rating of the auxiliary contact (typically 10A at 250V AC) — do not use for power load switching.
Q: What is the electrical and mechanical life of the LC1G400KUEN?
A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.
Q: Can the LC1G400KUEN be used for reversing duty (forward/reverse motor control)?
A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.
Q: Can multiple LC1G400KUEN contactors be wired for star-delta starting?
A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.













