LC1D40ABD | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 40 A - 24 V DC standard coil - Schneider Electric
₹27,530.00 Original price was: ₹27,530.00.₹12,388.50Current price is: ₹12,388.50. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
GV3G264 | 2 GV3 BREAKERS POWER BUSBAR – Schneider Electric
LADS2 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LADN20 | Auxiliary contact block, TeSys D, 2NO, front mounting, screw clamp terminals – Schneider Electric
LADT4 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LAD4T3B | TeSys Deca Bidirect Diode 12-24VAC/DC – Schneider Electric
LAD4D3U | TeSys Deca Diode 24-250VDC Suppressor – Schneider Electric
LADN22 | Auxiliary contact block, TeSys D, 2NO + 2NC, front mounting, screw clamp terminals – Schneider Electric
LADN11 | Auxiliary contact block, TeSys D, 1NO + 1NC, front mounting, screw clamp terminals – Schneider Electric
LADN02 | Auxiliary contact block, TeSys D, 2NC, front mounting, screw clamp terminals – Schneider Electric
LADR0 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LADN04 | Auxiliary contact block, TeSys D, 4NC, front mounting, screw clamp terminals – Schneider Electric
LADR4 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LAD9ET1S | TeSys SAFETY COVER RED FOR 09-38A – 40 – Schneider Electric
LAD9R3 | LC1D40A-D65A REVERSOR KIT – Schneider Electric
LADN31 | Auxiliary contact block, TeSys D, 3NO + 1NC, front mounting, screw clamp terminals – Schneider Electric
LADN40 | Auxiliary contact block, TeSys D, 4NO, front mounting, screw clamp terminals – Schneider Electric
LADR2 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LADN13 | Auxiliary contact block, TeSys D, 1NO + 3NC, front mounting, screw clamp terminals – Schneider Electric
LADT2 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LAD6K10B | LATCH BLK LC1 D09-D65A 24V – Schneider Electric
LADT0 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LAD4CM | Mechanical interlock, TeSys D contactors LC1D40A-D80A LC1DT60A-DT80A – Schneider Electric
Looking for the LC1D40ABD | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 40 A - 24 V DC standard coil? This genuine Schneider Electric contactor from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 60 A, Power circuit: <= 690 V AC 25...400 Hz, 3P. Order part number LC1D40ABD from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LC1D40ABD |
| Category | Contactor |
| Main | |
| Range | TeSys TeSys Deca |
| Range of product | TeSys Deca |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load Motor control |
| Utilisation category | AC-3 AC-3e AC-1 AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| [Uc] control circuit voltage | 24 V DC |
| Complementary | |
| Motor power kW | 11 kW at 220/230 V AC 50/60 Hz (AC-3) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 22 kW at 415/440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660/690 V AC 50/60 Hz (AC-3) 11 kW at 220/230 V AC 50/60 Hz (AC-3e) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e) 22 kW at 415/440 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 30 kW at 660/690 V AC 50/60 Hz (AC-3e) 9 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 60 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 320 A 40 °C – 10 s for power circuit 720 A 40 °C – 1 s for power circuit 72 A 40 °C – 10 min for power circuit 165 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 1.5 mOhm – Ith 60 A 50 Hz for power circuit |
| Power dissipation per pole | 2.4 W AC-3 5.4 W AC-1 2.4 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 0.7 Mcycles 60 A AC-1 at Ue <= 440 V 1.5 Mcycles 40 A AC-3 at Ue <= 440 V 1.5 Mcycles 40 A AC-3e at Ue <= 440 V |
| Control circuit type | DC standard |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.1…0.3 Uc (-40…70 °C):drop-out DC 0.75…1.25 Uc (-40…60 °C):operational DC 1…1.25 Uc (60…70 °C):operational DC |
| Inrush power in W | 19 W (at 20 °C) |
| Hold-in power consumption in W | 7.4 W at 20 °C |
| Operating time | 50 ±15 % ms closing 20 ±20 % ms opening |
| Time constant | 34 ms |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Connections – terminals | Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: solid without cable end |
| Tightening torque | Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25…400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
| Mounting support | Rail Plate |
| Environment | |
| Standards | EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 CSA C22.2 No 14 UL 60947-4-1 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ IEC 60335-1:Clause 30.2 |
| Product certifications | CCC UL CB Scheme CSA CE UKCA Marine EAC |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C 60…70 °C with derating |
| Operating altitude | 0…3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5…300 Hz) Vibrations contactor closed (4 Gn, 5…300 Hz) Shocks contactor closed (15 Gn for 11 ms) Shocks contactor open (10 Gn for 11 ms) |
| Height | 122 mm |
| Width | 55 mm |
| Depth | 120 mm |
| Product weight | 0.925 kg |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.200 cm |
| Package 1 Width | 13.700 cm |
| Package 1 Length | 15.200 cm |
| Package 1 Weight | 979.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 10.080 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 160 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 179.280 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 40 A AC-3 rated — suits up to a 18.5 kW squirrel-cage induction motor at 415V for direct-on-line (DOL) starting and running.
- 24V DC coil — connects directly to pushbutton station, PLC digital output, or timer relay; suitable for standard 50Hz Indian industrial control circuits.
- 3 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
- Main contacts rated up to 440V AC — compatible with 415V AC three-phase Indian supply and 480V AC North American systems.
- TeSys D series — world-standard contactor footprint; clip-on LA1D/LA4D auxiliary contact blocks and accessories attach without tools; compatible with TeSys LRD overload relays for direct-mount DOL starters.
- Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: Is the LC1D40ABD rated 40 A for AC-3 motor duty or AC-1 resistive duty?
A: The 40 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.
Q: The LC1D40ABD has a coil voltage of 24V DC — what control supply is needed?
A: This Schneider Electric device requires a 24V DC control supply connected to the coil terminals (A1 and A2). For DC coils, observe polarity where marked. DC coils produce no inrush and are preferred for PLC output cards. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.
Q: What circuit can the 3 NO (Normally Open) contacts of the LC1D40ABD switch at 440V AC?
A: The 3 NO (Normally Open) contacts on the LC1D40ABD are rated for switching at up to 440V AC. These auxiliary contacts are typically used for: (1) indication lamps and buzzers, (2) PLC input feedback to confirm device state, (3) interlocking with other contactors or relays in control circuits. Check the current rating of the auxiliary contact (typically 10A at 250V AC) — do not use for power load switching.
Q: Can multiple LC1D40ABD contactors be wired for star-delta starting?
A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.
Q: What is the electrical and mechanical life of the LC1D40ABD?
A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.