LC1D65008F5 TeSys D contactor 4P 2 NO 2 NC AC-1 lc1d65008m7 image 1500x1500
LC1D65008F7 | TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 80 A 110 V AC 50/60 Hz coil - Schneider Electric Original price was: ₹62,135.00.Current price is: ₹26,096.70. Excl. GST
Back to products
LC1D65008F5 TeSys D contactor 4P 2 NO 2 NC AC-1 lc1d65008m7 image 1500x1500
LC1D65008M7 | TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 80 A 220 V AC 50/60 Hz coil - Schneider Electric Original price was: ₹62,135.00.Current price is: ₹26,096.70. Excl. GST

LC1D65008M5 | TeSys D contactor – 4P(2 NO + 2 NC) – AC-1 – <= 440 V 80 A - 220 V AC 50 Hz coil - Schneider Electric

SKU: LC1D65008M5

Original price was: ₹63,770.00.Current price is: ₹28,696.50. Excl. GST

Dispatch By : 7 Weeks

Dispatch By : 7 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: LC1D65008M5

Same-day dispatch · GST invoice available

20 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LC1D65008M5 | TeSys D contactor – 4P(2 NO + 2 NC) – AC-1 – <= 440 V 80 A - 220 V AC 50 Hz coil? This genuine Schneider Electric contactor from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 80 A, Power circuit: <= 690 V AC 25...400 Hz, 4P. Order part number LC1D65008M5 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULC1D65008M5
CategoryContactor
Main
RangeTeSys
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50 Hz
Complementary
Compatibility codeLC1D
Pole contact composition2 NO + 2 NC
Protective coverWith
[Ith] conventional free air thermal current80 A (at 60 °C) for power circuit
Irms rated making capacity1000 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current520 A 40 °C – 10 s for power circuit
900 A 40 °C – 1 s for power circuit
110 A 40 °C – 10 min for power circuit
260 A 40 °C – 1 min for power circuit
Associated fuse rating125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
Average impedance1.5 mOhm – Ith 80 A 50 Hz for power circuit
Power dissipation per pole9.6 W AC-1
[Ui] rated insulation voltagePower circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability6 Mcycles
Electrical durability1.4 Mcycles 80 A AC-1 at Ue <= 440 V
Control circuit typeAC at 50 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.3…0.6 Uc (-40…70 °C):drop-out AC 50 Hz
1…1.1 Uc (60…70 °C):operational AC 50 Hz
Inrush power in VA160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation4…5 W at 50 Hz
Operating time4…19 ms opening
12…26 ms closing
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 8 N.m – on screw clamp terminals – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on screw clamp terminals – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Mounting supportPlate
Rail
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
Product certificationsCSA
CCC
RINA
LROS (Lloyds register of shipping)
GL
UL
DNV
GOST
BV
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessShocks contactor open (8 Gn for 11 ms)
Shocks contactor closed (10 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Height127 mm
Width85 mm
Depth125 mm
Product weight1.45 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.500 cm
Package 1 Width10.700 cm
Package 1 Length13.500 cm
Package 1 Weight1.475 kg
Unit Type of Package 2S02
Number of Units in Package 25
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.673 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 80 A AC-3 rated — suits up to a 37 kW squirrel-cage induction motor at 415V for direct-on-line (DOL) starting and running.
  • 220V AC coil — connects directly to pushbutton station, PLC digital output, or timer relay; suitable for standard 50Hz Indian industrial control circuits.
  • 4 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
  • Main contacts rated up to 440V AC — compatible with 415V AC three-phase Indian supply and 480V AC North American systems.
  • TeSys D series — world-standard contactor footprint; clip-on LA1D/LA4D auxiliary contact blocks and accessories attach without tools; compatible with TeSys LRD overload relays for direct-mount DOL starters.
  • Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LAD9ET1SLA4DA2ULADN22LADN11LADN20LAD8N11LADT2LADN40LADN31LADN02LADT0LAD8N20LADS2LADR2LADR0LADN04LADN13LADR4LADT4LAD8N02LX1D6M5

❓ Frequently Asked Questions

Q: Is the LC1D65008M5 rated 80 A for AC-3 motor duty or AC-1 resistive duty?

A: The 80 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.

Q: The LC1D65008M5 has a coil voltage of 220V AC — what control supply is needed?

A: This Schneider Electric device requires a 220V AC control supply connected to the coil terminals (A1 and A2). For AC coils, ensure the control circuit voltage is stable — voltage drops below 85% of rated coil voltage can cause chatter and coil overheating. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.

Q: What circuit can the 2 NO + 2 NC contacts of the LC1D65008M5 switch at 440V AC?

A: The 2 NO + 2 NC contacts on the LC1D65008M5 are rated for switching at up to 440V AC. These auxiliary contacts are typically used for: (1) indication lamps and buzzers, (2) PLC input feedback to confirm device state, (3) interlocking with other contactors or relays in control circuits. Check the current rating of the auxiliary contact (typically 10A at 250V AC) — do not use for power load switching.

Q: What is the electrical and mechanical life of the LC1D65008M5?

A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.

Q: Can the LC1D65008M5 be used for reversing duty (forward/reverse motor control)?

A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.

Customer Reviews