LC1F2254 | TeSys F contactor – 4P(4 NO)-AC-1 <= 440V 315A with coil LX9 - 24...575V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC - Schneider Electric

SKU: LC1F2254

Original price was: ₹162,055.00.Current price is: ₹137,746.75. Excl. GST

Out of stock

Out of stock

18 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LC1F2254 | TeSys F contactor – 4P(4 NO)-AC-1 <= 440V 315A with coil LX9 - 24...575V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC? This genuine Schneider Electric contactor from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 315 A, <= 690 V AC 50/60 Hz, 4P. Order part number LC1F2254 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULC1F2254
CategoryContactor
Main
RangeTeSys
Product nameTeSys F
Product or component typeContactor
Device short nameLC1F
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
power pole contact composition4 NO
[Ue] rated operational voltage<= 690 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current315 A (at <40 °C) at <= 440 V AC-1
Complementary
[Uc] control circuit voltage24…575 V AC 40…400 Hz with LX9 coil
24…460 V DC with LX4 coil
100…250 V AC 50/60 Hz with LXE coil
100…380 V DC with LXE coil
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current315 A (at 40 °C)
Irms rated making capacity2250 A conforming to IEC 60947-4-1
Rated breaking capacity1800 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current1800 A 40 °C – 10 s
1000 A 40 °C – 30 s
850 A 40 °C – 1 min
560 A 40 °C – 3 min
440 A 40 °C – 10 min
Associated fuse rating315 A gG at <= 440 V
Average impedance0.32 mOhm – Ith 315 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
Power dissipation per pole32 W AC-1
Control circuit voltage limitsOperational: 0.85…1.1 Uc AC 40…400 Hz with LX9 coil
Drop-out: 0.2…0.55 Uc AC 40…400 Hz with LX9 coil
Operational: 0.85…1.1 Uc DC with LX4 coil
Drop-out: 0.15…0.2 Uc DC with LX4 coil
Operational: 85…275 V AC 50/60 Hz with LXE coil
Drop-out: 0…60 V AC 50/60 Hz with LXE coil
Operational: 85…418 V DC with LXE coil
Drop-out: 0…45 V DC with LXE coil
Heat dissipation8…9.8 W
2.2…2.5 W
Operating time35 ms closing for with LX9 coil
130 ms opening for with LX9 coil
30…40 ms closing for with LX4 coil
30…50 ms opening for with LX4 coil
40…80 ms closing for with LXE coil
6…54 ms opening for with LXE coil
Mounting supportPlate
StandardsJIS C8201-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
EN 60947-1
Product certificationsUL
LROS (Lloyds register of shipping)
BV
CB
ABS
DNV
CSA
RMRoS
RINA
UKCA
Connections – terminalsPower circuit: lugs-ring terminals 1 cable(s) 185 mm²
Power circuit: connector 1 cable(s) 185 mm²
Power circuit: bar 2 cable(s) – busbar cross section: 32 x 4 mm
Power circuit: bolted connection
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
Tightening torquePower circuit: 35 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
Mechanical durability10 Mcycles
Inrush power in VA950…1180 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX9 coil
737…902 VA (at 20 °C)with LX4 coil
280…310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
270…320 VA (at 20 °C)with LXE coil
Hold-in power consumption in VA8.9…10.9 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX9 coil
4.13…5.07 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
Maximum operating rate2400 cyc/h 55 °C
Compatibility codeLC1F
Environment
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
Protective treatmentTH
Ambient air temperature for operation-5…55 °C
Ambient air temperature for storage-60…80 °C
Permissible ambient air temperature around the device-40…70 °C
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5…300 Hz
Vibrations contactor closed: 5 Gn, 5…300 Hz
Shocks contactor open: 7 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
Height197 mm
Width208.5 mm
Depth181 mm
Product weight5.55 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height22.000 cm
Package 1 Width24.500 cm
Package 1 Length27.000 cm
Package 1 Weight5.595 kg
Unit Type of Package 2P06
Number of Units in Package 212
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight75.460 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 315 A AC-3 rated for motor and resistive load switching at LV.
  • 24–575V AC coil — connects directly to pushbutton station, PLC digital output, or timer relay; suitable for standard 50Hz Indian industrial control circuits.
  • 4 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
  • Main contacts rated up to 440V AC — compatible with 415V AC three-phase Indian supply and 480V AC North American systems.
  • TeSys F heavy-duty series — reinforced contacts for high-current motor, capacitor bank, and resistive load switching beyond TeSys D current range.
  • Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LX9FG220

❓ Frequently Asked Questions

Q: Is the LC1F2254 rated 315 A for AC-3 motor duty or AC-1 resistive duty?

A: The 315 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.

Q: The LC1F2254 has a coil voltage of 24–575V AC — what control supply is needed?

A: This Schneider Electric device requires a 24–575V AC control supply connected to the coil terminals (A1 and A2). For AC coils, ensure the control circuit voltage is stable — voltage drops below 85% of rated coil voltage can cause chatter and coil overheating. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.

Q: What circuit can the 4 NO (Normally Open) contacts of the LC1F2254 switch at 440V AC?

A: The 4 NO (Normally Open) contacts on the LC1F2254 are rated for switching at up to 440V AC. These auxiliary contacts are typically used for: (1) indication lamps and buzzers, (2) PLC input feedback to confirm device state, (3) interlocking with other contactors or relays in control circuits. Check the current rating of the auxiliary contact (typically 10A at 250V AC) — do not use for power load switching.

Q: Can the LC1F2254 be used for reversing duty (forward/reverse motor control)?

A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.

Q: Can multiple LC1F2254 contactors be wired for star-delta starting?

A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.

Customer Reviews