LA7K0064 | TeSys K thermal overload relays – terminal block – LA7K – Schneider Electric
₹2,525.00 Original price was: ₹2,525.00.₹1,136.25Current price is: ₹1,136.25. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LR2K0322 | TeSys K – differential thermal overload relays – 12…16 A – class 10A – Schneider Electric
LR2K0304 | TeSys K – differential thermal overload relays – 0.36…0.54 A – class 10A – Schneider Electric
LR2K0310 | TeSys K – differential thermal overload relays -2.6…3.7 A – class 10A – Schneider Electric
LR2K0308 | TeSys K – differential thermal overload relays – 1.8…2.6 – class 10A – Schneider Electric
LR2K0312 | TeSys K – differential thermal overload relays – 3.7…5.5 A – class 10A – Schneider Electric
LR2K0321 | TeSys K – differential thermal overload relays – 10…14 A – class 10A – Schneider Electric
LR2K0303 | TeSys K – differential thermal overload relays – 0.23…0.36 A – class 10A – Schneider Electric
LR2K0314 | TeSys K – differential thermal overload relays – 5.5…8 A – class 10A – Schneider Electric
LR2K0302 | TESYS K OVERLOAD RELAY CL10 0.16 – 0.23A – Schneider Electric
LR7K0310 | thermal overload relay for mo to r 2.6 t – Schneider Electric
LR7K0314 | TESYS LR7K OLR CL10A 5.5-8A – Schneider Electric
LR2K0307 | TeSys K – differential thermal overload relays – 1.2…1.8 A – class 10A – Schneider Electric
LR2K0301 | TeSys K – differential thermal overload relays – 0.11…0.16 A – class 10A – Schneider Electric
Looking for the LA7K0064 | TeSys K thermal overload relays – terminal block – LA7K? This genuine Schneider Electric overload relay from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Order part number LA7K0064 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LA7K0064 |
| Category | Overload Relay |
| Main | |
| Range | TeSys |
| Product or component type | Terminal block |
| Device short name | LA7K |
| Accessory / separate part category | Connection accessory |
| Mounting support | Rail |
| Product compatibility | LR2K LR7K |
| Complementary | |
| Connections – terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Tightening torque | 0.8 N.m – on screw clamp terminals – with screwdriver Philips No 2 0.8 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm |
| Height | 80 mm |
| Width | 45 mm |
| Depth | 75 mm |
| Product weight | 0.1 kg |
| Quantity per set | Set of 10 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.500 cm |
| Package 1 Width | 6.000 cm |
| Package 1 Length | 4.800 cm |
| Package 1 Weight | 51.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 50 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 2.724 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Bimetal thermal element with phase-loss sensitivity — independently monitors each phase; trips if any phase carries more than ~115% of the set current, or on complete phase failure.
- Normally open (NO) and normally closed (NC) auxiliary contacts built in — NO contact wired to motor run indicator; NC contact wired to PLC fault input or motor starter stop circuit.
- Direct clip-on mounting to TeSys LC1 contactors — no external wiring between overload and contactor; forms a complete IEC 60947-4-1 DOL motor starter combination.
- Manual/automatic reset selectable — set to manual for attended machinery requiring operator acknowledgement; auto-reset for unattended remote installations.
- Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: Does the LA7K0064 provide single-phase (phase loss) protection?
A: Schneider Electric thermal overload relays include single-phase sensitivity: if one phase is lost, the remaining phases carry higher current, causing the bimetal to heat and trip within the specified time. For critical motors, add a dedicated phase-loss relay for faster response independent of load — overload relay phase-loss protection is load-dependent and may take minutes to trip at light load.
Q: How do I set the LA7K0064 to protect a motor without causing nuisance trips on starting?
A: Set the thermal overload dial to the motor’s nameplate full-load current (FLC). For star-delta starters, set the overload relay to 58% of motor FLC (line current in delta = FLC × 0.58). Allow 10 trips for the relay’s thermal memory to stabilise before adjusting the setting.
Q: What is the difference between an Overload Relay and a standard MCB — and why use the LA7K0064?
A: A standard MCB protects against overload and short-circuit only. An Overload Relay provides thermal overload protection calibrated to motor FLC, protecting the motor from sustained overloads that would destroy windings before a standard MCB trips. Choose the LA7K0064 when the application specifically requires overload relay characteristics.