TPRSS038 | TeSys island SIL Starter 38 A / 18,5 kW - Schneider Electric
₹43,435.00 Original price was: ₹43,435.00.₹24,323.60Current price is: ₹24,323.60. Excl. GST
TPRSS080 | TeSys island SIL Starter 80 A / 37 kW - Schneider Electric
₹59,075.00 Original price was: ₹59,075.00.₹31,457.44Current price is: ₹31,457.44. Excl. GST
TPRSS065 | TeSys island SIL Starter 65 A / 30 kW – Schneider Electric
SKU:
TPRSS065
₹54,435.00 Original price was: ₹54,435.00.₹28,986.64Current price is: ₹28,986.64. Excl. GST
Dispatch By : 2 Weeks
Dispatch By : 2 Weeks
14
People watching this product now!
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included
Dedicated account manager
Technical support
Bulk & business pricing
3-day replacement
Specifications
| Main | |
|---|---|
| Range | TeSys |
| Product name | TeSys island |
| Device short name | TPRSS |
| Product or component type | SIL motor starter |
| Motor starter type | Direct on line |
| Device presentation | Direct starter connected to an automation controller through a bus coupler Operational only when connected to a bus coupler |
| Function available | Upstream voltage presence detection Electrical line and load protection Power and energy monitoring when connected with TPRVM voltage module Safe stop function available when connected with a TPRSM module |
| Product compatibility | TPRBC bus coupler TPRVM voltage interface module TPRSM SIL interface module |
| Poles description | 3P (3 NO) |
| Utilisation category | AC-1 AC-2 AC-3 AC-4 AC-3e |
| Motor power kW | 18.5 kW at 230 V 50 Hz (AC-3) 30 kW at 380…415 V 50 Hz (AC-3) 30 kW at 440 V 50 Hz (AC-3) 37 kW at 500 V 50 Hz (AC-3) 37 kW at 690 V 50 Hz (AC-3) |
| motor power HP (UL / CSA) | 5 hp at 120 V AC 60 Hz for 1 phase motors 10 hp at 240 V AC 60 Hz for 1 phase motors 20 hp at 208 V AC 60 Hz for 3 phases motors 20 hp at 240 V AC 60 Hz for 3 phases motors 40 hp at 480 V AC 60 Hz for 3 phases motors 50 hp at 600 V AC 60 Hz for 3 phases motors |
| [Ue] rated operational voltage | <= 690 V AC 47…63 Hz |
| [Ie] rated operational current | 65 A (at <50 °C) at <= 440 V AC-3 80 A (at <50 °C) at <= 440 V AC-1 |
| [Ith] conventional free air thermal current | 80 A (at 50 °C) |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| Overvoltage category | III |
| Thermal protection adjustment range | 3.35…65 A |
| Thermal overload class | Class 5…30 |
| Reset | Remotely or automatically |
| Irms rated making capacity | 1000 A at 440 V conforming to IEC 60947 |
| Rated breaking capacity | 1000 A at 440 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 900 A 40 °C – 1 s 520 A 40 °C – 10 s 260 A 40 °C – 1 min 110 A 40 °C – 10 min |
| Average impedance | 1.5 mOhm – Ith 80 A 50 Hz |
| Power dissipation per pole | 6.3 W AC-3 – Ith 65 A 9.6 W AC-1 – Ith 80 A |
| [Uc] control circuit voltage | 24 V DC supplied by the bus coupler |
| Current consumption | 80 mA contactor sealed 500 mA contactor closing |
| Power dissipation in W | 20.8 W at Ie AC-3 |
| Complementary | |
| Mechanical durability | 6 Mcycles |
| Electrical durability | 1.4 Mcycles 65 A AC-3 at Ue 440 V 0.5 Mcycles 80 A AC-1 at Ue 440 V |
| Maximum operating rate | 3600 cyc/mn AC-3 |
| Operating time | < 80 ms closing < 80 ms opening |
| Safety function | Safe stop: category 0 conforming to IEC 60204-1 when associated with a TPRSM module Safe stop: category 1 conforming to IEC 60204-1 when associated with a TPRSM module |
| Safety integrity level | SIL 2 conforming to IEC 61508 in single channel system architecture SILCL 2 conforming to IEC 62061 in single channel system architecture PL = d category 2 conforming to ISO 13849-1 in single channel system architecture |
| Safety performance level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Protection type | Thermal overload protection Motor overheat Overcurrent Undercurrent Jam Long start Stall Rapid cycle lockout Phase sequence Rapid restart lockout Phase reversal Phase loss Phase unbalance Ground current |
| Monitoring type | Time device ON Time device switch ON Number of faults Number of switching cycles Number of device power cycles Average current Iavg Average voltage Vavg Max current Imax Max voltage Vmax Active and reactive power with voltage module Active and reactive energy with voltage module True power factor with voltage module |
| Local signalling | 1 LED (green/red) for DS (device status) 1 LED (green/red) for LS (load status) |
| Standards | EN/IEC 60947-1 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 |
| Product certifications | CSA UL EAC CCC |
| Mounting mode | Horizontal and vertical (35 mm symmetrical DIN rail) |
| Connections – terminals | EverLink BTR screw connectors 1 cable(s) 1…35 mm² (16 AWG…2 AWG) rigid EverLink BTR screw connectors 2 cable(s) 1…25 mm² (16 AWG…4 AWG) rigid EverLink BTR screw connectors 1 cable(s) 1…35 mm² (16 AWG…2 AWG) flexible without cable end EverLink BTR screw connectors 2 cable(s) 1…25 mm² (16 AWG…4 AWG) flexible without cable end EverLink BTR screw connectors 1 cable(s) 1…35 mm² (16 AWG…2 AWG) flexible with cable end EverLink BTR screw connectors 2 cable(s) 1…25 mm² (16 AWG…4 AWG) flexible with cable end |
| Tightening torque | 5 N.m – cable 1…25 mm² hexagonal 4 mm 8 N.m – cable 25…35 mm² hexagonal 4 mm |
| Width | 55 mm |
| Height | 167 mm |
| Depth | 125 mm |
| Net weight | 1.248 kg |
| Environment | |
| Ambient air temperature for storage | -25…70 °C |
| Ambient air temperature for operation | -10…50 °C without derating 50…60 °C with current derating |
| Relative humidity | 5…95 % |
| Operating altitude | 0…2000 m without derating |
| IP degree of protection | IP20 |
| Pollution degree | 2 |
| Protective treatment | TC |
| Fire resistance | 960 °C conforming to UL 94 850 °C conforming to IEC 60695-2-1 650 °C conforming to IEC 60695-2-12 |
| Shock resistance | 15 gn (duration = 11 ms) conforming to IEC 60068-2-27 |
| Vibration resistance | 1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| Electromagnetic compatibility | Electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 Surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 Surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 Conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.500 cm |
| Package 1 Width | 15.000 cm |
| Package 1 Length | 19.500 cm |
| Package 1 Weight | 1.353 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 8 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 11.312 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
Customer Reviews
Related Products
XB5AR31N | Push button, Harmony XB5N XB7N, plastic, mushroom, green, 60mm, spring return, unmarked, 1 NO – Schneider Electric
SKU:
XB5AR31N
ZB2BW36C | Ø 22 mm fixing hole – push button head with blue lamp – Schneider Electric
SKU:
ZB2BW36C
MS13MD09 | 7MDL, 1HP 3 PHASE DOL STARTER – Schneider Electric
SKU:
MS13MD09
30002572 | EM1200 Energy meter Cl 0.5 RS485 LCD – Schneider Electric
SKU:
30002572