TPRSS080 | TeSys island SIL Starter 80 A / 37 kW - Schneider Electric
TPRSS080 | TeSys island SIL Starter 80 A / 37 kW - Schneider Electric Original price was: ₹59,075.00.Current price is: ₹31,457.44. Excl. GST
Back to products
TPSAUX43 | OF for source position for TA25,TA63 - Schneider Electric
TPSAUX43 | OF for source position for TA25,TA63 - Schneider Electric Original price was: ₹3,675.00.Current price is: ₹3,160.50. Excl. GST

TPRST080 | TeSys island Starter 80 A / 37 kW – Schneider Electric

SKU: TPRST080

Original price was: ₹53,285.00.Current price is: ₹28,374.26. Excl. GST

Dispatch By : 7 Weeks

Dispatch By : 7 Weeks

10 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeTeSys
Product nameTeSys island
Device short nameTPRST
Product or component typeMotor starter
Motor starter typeDirect on line
Device presentationDirect starter connected to an automation controller through a bus coupler
Operational only when connected to a bus coupler
Function availableUpstream voltage presence detection
Electrical line and load protection
Power and energy monitoring when connected with TPRVM voltage module
Product compatibilityTPRBC bus coupler
TPRVM voltage interface module
Poles description3P (3 NO)
Utilisation categoryAC-1
AC-2
AC-3
AC-4
AC-3e
Motor power kW18.5 kW at 230 V 50 Hz (AC-3)
37 kW at 380…415 V 50 Hz (AC-3)
37 kW at 440 V 50 Hz (AC-3)
37 kW at 500 V 50 Hz (AC-3)
37 kW at 690 V 50 Hz (AC-3)
motor power HP (UL / CSA)5 hp at 120 V AC 60 Hz for 1 phase motors
10 hp at 240 V AC 60 Hz for 1 phase motors
20 hp at 208 V AC 60 Hz for 3 phases motors
20 hp at 240 V AC 60 Hz for 3 phases motors
40 hp at 480 V AC 60 Hz for 3 phases motors
50 hp at 600 V AC 60 Hz for 3 phases motors
[Ue] rated operational voltage<= 690 V AC 47…63 Hz
[Ie] rated operational current66 A (at <50 °C) at <= 440 V AC-3
80 A (at <50 °C) at <= 440 V AC-1
[Ith] conventional free air thermal current80 A (at 50 °C)
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
600 V conforming to UL 60947-4-1
600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
Overvoltage categoryIII
Thermal protection adjustment range4…80 A
Thermal overload classClass 5…30
ResetRemotely or automatically
Irms rated making capacity1000 A at 440 V conforming to IEC 60947
Rated breaking capacity1000 A at 440 V conforming to IEC 60947
[Icw] rated short-time withstand current900 A 40 °C – 1 s
520 A 40 °C – 10 s
260 A 40 °C – 1 min
110 A 40 °C – 10 min
Average impedance1.5 mOhm – Ith 80 A 50 Hz
Power dissipation per pole6.5 W AC-3
9.6 W AC-1
[Uc] control circuit voltage24 V DC supplied by the bus coupler
Current consumption80 mA contactor sealed
500 mA contactor closing
Power dissipation in W21.4 W at Ie AC-3
Complementary
Mechanical durability6 Mcycles
Electrical durability0.75 Mcycles 66 A AC-3 at Ue 440 V
0.5 Mcycles 80 A AC-1 at Ue 440 V
Maximum operating rate3600 cyc/mn AC-3
Operating time< 80 ms closing
< 80 ms opening
Safety performance levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Protection typeThermal overload protection
Motor overheat
Overcurrent
Undercurrent
Jam
Long start
Stall
Rapid cycle lockout
Rapid restart lockout
Phase sequence
Phase loss
Phase reversal
Phase unbalance
Ground current
Monitoring typeTime device ON
Time device switch ON
Number of faults
Number of switching cycles
Number of device power cycles
Average current Iavg
Average voltage Vavg
Max current Imax
Max voltage Vmax
Active and reactive power with voltage module
Active and reactive energy with voltage module
True power factor with voltage module
Local signalling1 LED (green/red) for DS (device status)
1 LED (green/red) for LS (load status)
StandardsEN/IEC 60947-1
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsUL
CSA
CCC
EAC
Mounting modeHorizontal and vertical (35 mm symmetrical DIN rail)
Connections – terminalsEverLink BTR screw connectors 1 cable(s) 1…35 mm² (16 AWG…2 AWG) rigid
EverLink BTR screw connectors 2 cable(s) 1…25 mm² (16 AWG…4 AWG) rigid
EverLink BTR screw connectors 1 cable(s) 1…35 mm² (16 AWG…2 AWG) flexible without cable end
EverLink BTR screw connectors 2 cable(s) 1…25 mm² (16 AWG…4 AWG) flexible without cable end
EverLink BTR screw connectors 1 cable(s) 1…35 mm² (16 AWG…2 AWG) flexible with cable end
EverLink BTR screw connectors 2 cable(s) 1…25 mm² (16 AWG…4 AWG) flexible with cable end
Tightening torque5 N.m – cable 1…25 mm² hexagonal 4 mm
8 N.m – cable 25…35 mm² hexagonal 4 mm
Width55 mm
Height167 mm
Depth125 mm
Net weight1.248 kg
Environment
Ambient air temperature for storage-25…70 °C
Ambient air temperature for operation-10…50 °C without derating
50…60 °C with current derating
Relative humidity5…95 %
Operating altitude0…2000 m without derating
IP degree of protectionIP20
Pollution degree2
Protective treatmentTC
Fire resistance960 °C conforming to UL 94
850 °C conforming to IEC 60695-2-1
650 °C conforming to IEC 60695-2-12
Shock resistance15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Electromagnetic compatibilityElectrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4
Surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5
Surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5
Conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.000 cm
Package 1 Width15.000 cm
Package 1 Length19.500 cm
Package 1 Weight1.351 kg
Unit Type of Package 2S03
Number of Units in Package 28
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight11.304 kg
Contractual warranty
Warranty (in months)18

Customer Reviews