LU2MB0BL REVERSER BLOCK 32A 24V DC Schneider Electric lu2mb0bl
LU2MB0BL | REVERSER BLOCK 32A 24V DC - Schneider Electric Original price was: ₹70,725.00.Current price is: ₹37,661.06. Excl. GST
Back to products
C25F3MA220 NSX250F 36kA AC 3P3D 220A MA Schneider Electric c25f3ma220
C25F3MA220 | NSX250F 36kA AC 3P3D 220A MA - Schneider Electric Original price was: ₹67,730.00.Current price is: ₹32,510.40. Excl. GST

VPL06N | Varplus Logic Controller, 6 Step Outputs – Schneider Electric

SKU: VPL06N

Original price was: ₹65,256.00.Current price is: ₹30,670.32. Excl. GST

Dispatch By : 7 Weeks

Dispatch By : 7 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: VPL06N

Same-day dispatch · GST invoice available

19 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The Schneider Electric VPL06N is an electrical component from the PowerLogic range, engineered for industrial, commercial, and infrastructure applications in demanding Indian and international installations. Key ratings include Front face: IP41. Buy the VPL06N | Varplus Logic Controller, 6 Step Outputs online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUVPL06N
CategoryElectrical Component
Main
RangePowerLogic
Product namePowerLogic PFC Controller
Product or component typePower factor controller
Device short nameVPL6
Complementary
Number of step output contacts6
[Us] rated supply voltage90…550 V AC
<= 999 kV AC with external VT
Measurement current0…5 A
Measurement voltage90…550 V AC 50/60 Hz
Operating modeManual or automatic
Number of quadrant operation for generator application4
Device connectionCommunication protocol: Modbus interface: RS485
Input functionSwitch: 1 x dry contact
Colour codeFront: dark grey RAL 7016
Display typeBacklit LCD
Display size56 x 25 mm
Function availableAutomatic detection
Advanced programming (expert)
Manual programming
Any step sequence
Automatic initialisation
Metering typePower factor and displacement PF (signed, four quadrant)
Total current harmonic distortion THD (I)
Power factor average over lifetime
Temperature maximum
Phase current I1, I2, I3 RMS on load
Active power P, P1, P2, P3 on load
Reactive power Q, Q1, Q2, Q3 on load
Apparent power S, S1, S2, S3 on load
Voltage U21, U32, U13, V1, V2, V3 on load
Type of measurementAmbient temperature inside the cubicle
Tan φ
Individual voltage harmonic
Cos φ
Operating time
Power factor
Capacitor current overload Irms/I1
Information displayedNumber of switching cycles per step
Remaining step capacity in %
Individual step size in kVAr
Type of alarmsStep power loss (< 75 %) / Action: message and alarm contact + step blocked
Step faulty / Action: message and alarm contact + step blocked
High current (> 6 A CT) / Action: message and alarm contact
Hunting (unstable regulation) / Action: message and alarm contact + step blocked
Low current (< 15 mA CT) / Action: message and alarm contact
Overcompensation / Action: message and alarm contact
Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off
Overtemperature (50 °C) / Action: message and alarm contact + step switched off
Overtemperature (30 °C) / Action: fan switch
Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped
Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
Data recording5 alarms
Operational Hours alarm100000 h without maintenance
Operational counter alarm65000 cycles without maintenance
Input typeInsensitive to phase rotation polarity
Insensitive to CT polarity
Phase to neutral
Current input CT…X/5 A and X/1 A
Phase to phase
Output typeControl relay: 0.2 A 110 V DC
Control relay: 1 A 48 V DC
Control relay: 2 A 400 V AC 50/60 Hz
Control relay: 1 A 24 V DC
Control relay: 5 A 250 V AC 50/60 Hz
Control relay: 5 A 120 V AC 50/60 Hz
Fan: 5 A 250 V AC 50/60 Hz
Fan: 1 A 48 V DC
Alarm relay: 5 A 250 V AC 50/60 Hz
Alarm relay: 1 A 48 V DC
Maximum at the common terminal10 A
Settings operating modeManual
Automatic
Type of settingChoice of stepping programs: auto
Choice of stepping programs: LIFO
Choice of stepping programs: linear
Delay between 2 successive switch on the same step: 5…1200 s
Step configuration programming: auto
Step configuration programming: off
Step configuration programming: fixed
Target cos phi: 0.7 inductive…0.7 capacitive
Target cos phi: dual cos φ
Measurement accuracyVoltage +/- 1 %
Current +/- 1 %
Frequency +/- 1 %
Energy (P,Q,S) +/- 2 %
Cos φ +/- 2 %
Total voltage harmonic distortion THD (U) +/- 2 %
Individual voltage harmonic +/- 3 %
Temperature +/- 3 °C
Time delay range1…6500 s (on reconnection)
1…6500 s (on response)
Provided equipmentUser manual
Mounting modeFlush-mounted
Mounting supportPanel – thickness: 1…3 mm
Mounting locationIn cabinet
Cut-out dimensions138 x 138 mm
Height144 mm
Width144 mm
Depth58 mm
Product weight0.6 kg
Compatibility codeVPL 6
Environment
StandardsIEC 61000-6-2
EN 61010-1
IEC 61000-6-4
IEC 61326-1
UL 61010-1
Product certificationsEAC
NRTL
cNRTL
CE
IP degree of protectionFront face: IP41
Rear face: IP20
Operating altitude<= 2000 m
Ambient air temperature for operation-20…60 °C
Ambient air temperature for storage-40…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.200 cm
Package 1 Width17.800 cm
Package 1 Length18.400 cm
Package 1 Weight696.000 g
Unit Type of Package 2S03
Number of Units in Package 28
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.050 kg
Unit Type of Package 3P06
Number of Units in Package 364
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight60.348 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

Customer Reviews