LV432639 48 60V AC 50 60HZ MT400 630 Schneider Electric lv
LV432639 | 48 60V AC 50 60HZ MT400 630 - Schneider Electric Original price was: ₹76,570.00.Current price is: ₹38,667.85. Excl. GST
Back to products
GV2LE03 GV2 MOTOR CB MAGNETIC 0.4A TOGGLE SWITCH Schneider Electric mpcb tesys
GV5P220H | GV5P220H 3P 70kA Motor Circuit Breaker - Schneider Electric Original price was: ₹90,705.00.Current price is: ₹40,817.25. Excl. GST

VPL12N | Varplus Logic Controller, 12 Step Output – Schneider Electric

SKU: VPL12N

Original price was: ₹70,461.00.Current price is: ₹26,775.18. Excl. GST

Dispatch By : 3 Weeks

Dispatch By : 3 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: VPL12N

Same-day dispatch · GST invoice available

12 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The Schneider Electric VPL12N is an electrical component from the PowerLogic range, engineered for industrial, commercial, and infrastructure applications in demanding Indian and international installations. Key ratings include Front face: IP41. Buy the VPL12N | Varplus Logic Controller, 12 Step Output online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUVPL12N
CategoryElectrical Component
Main
RangePowerLogic
Product namePowerLogic PFC Controller
Product or component typePower factor controller
Device short nameVPL12
Complementary
Number of step output contacts12
[Us] rated supply voltage90…550 V AC
<= 999 kV AC with external VT
Measurement current0…5 A
Measurement voltage90…550 V AC 50/60 Hz
Operating modeManual or automatic
Number of quadrant operation for generator application4
Device connectionCommunication protocol: Modbus interface: RS485
Input functionSwitch: 1 x dry contact
Colour codeFront: dark grey RAL 7016
Display typeBacklit LCD
Display size56 x 25 mm
Function availableManual programming
Automatic initialisation
Automatic detection
Advanced programming (expert)
Any step sequence
Metering typePower factor and displacement PF (signed, four quadrant)
Total current harmonic distortion THD (I)
Power factor average over lifetime
Temperature maximum
Phase current I1, I2, I3 RMS on load
Active power P, P1, P2, P3 on load
Reactive power Q, Q1, Q2, Q3 on load
Apparent power S, S1, S2, S3 on load
Voltage U21, U32, U13, V1, V2, V3 on load
Type of measurementCapacitor current overload Irms/I1
Individual voltage harmonic
Power factor
Operating time
Cos φ
Ambient temperature inside the cubicle
Tan φ
Information displayedNumber of switching cycles per step
Individual step size in kVAr
Remaining step capacity in %
Type of alarmsStep power loss (< 75 %) / Action: message and alarm contact + step blocked
Step faulty / Action: message and alarm contact + step blocked
High current (> 6 A CT) / Action: message and alarm contact
Hunting (unstable regulation) / Action: message and alarm contact + step blocked
Low current (< 15 mA CT) / Action: message and alarm contact
Overcompensation / Action: message and alarm contact
Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off
Overtemperature (50 °C) / Action: message and alarm contact + step switched off
Overtemperature (30 °C) / Action: fan switch
Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped
Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
Data recording5 alarms
Operational Hours alarm100000 h without maintenance
Operational counter alarm65000 cycles without maintenance
Input typePhase to phase
Phase to neutral
Insensitive to CT polarity
Insensitive to phase rotation polarity
Current input CT…X/5 A and X/1 A
Output typeControl relay: 0.2 A 110 V DC
Control relay: 1 A 48 V DC
Control relay: 2 A 400 V AC 50/60 Hz
Control relay: 1 A 24 V DC
Control relay: 5 A 250 V AC 50/60 Hz
Control relay: 5 A 120 V AC 50/60 Hz
Fan: 5 A 250 V AC 50/60 Hz
Fan: 1 A 48 V DC
Alarm relay: 5 A 250 V AC 50/60 Hz
Alarm relay: 1 A 48 V DC
Maximum at the common terminal10 A
Settings operating modeAutomatic
Manual
Type of settingChoice of stepping programs: auto
Choice of stepping programs: LIFO
Choice of stepping programs: linear
Delay between 2 successive switch on the same step: 5…1200 s
Step configuration programming: auto
Step configuration programming: off
Step configuration programming: fixed
Target cos phi: 0.7 inductive…0.7 capacitive
Target cos phi: dual cos φ
Measurement accuracyVoltage +/- 1 %
Current +/- 1 %
Frequency +/- 1 %
Energy (P,Q,S) +/- 2 %
Cos φ +/- 2 %
Total voltage harmonic distortion THD (U) +/- 2 %
Individual voltage harmonic +/- 3 %
Temperature +/- 3 °C
Time delay range1…6500 s (on reconnection)
1…6500 s (on response)
Provided equipmentUser manual
Mounting modeFlush-mounted
Mounting supportPanel – thickness: 1…3 mm
Mounting locationIn cabinet
Cut-out dimensions138 x 138 mm
Height144 mm
Width144 mm
Depth58 mm
Product weight0.6 kg
Compatibility codeVPL 12
Environment
StandardsIEC 61000-6-4
UL 61010-1
EN 61010-1
IEC 61000-6-2
IEC 61326-1
Product certificationsEAC
NRTL
cNRTL
CE
IP degree of protectionFront face: IP41
Rear face: IP20
Operating altitude<= 2000 m
Ambient air temperature for operation-20…60 °C
Ambient air temperature for storage-40…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.200 cm
Package 1 Width17.700 cm
Package 1 Length18.400 cm
Package 1 Weight727.000 g
Unit Type of Package 2S03
Number of Units in Package 28
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.155 kg
Unit Type of Package 3P06
Number of Units in Package 364
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight58.408 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

Customer Reviews