Back to products
LC1E0601BD | Easy TeSys Control 3P 06A 1NC - Schneider Electric
LC1E0601BD | Easy TeSys Control 3P 06A 1NC - Schneider Electric Original price was: ₹4,270.00.Current price is: ₹1,793.40. Excl. GST

LC1DT40P7 | TeSys contactor 4P AC1 440V 40 A – Schneider Electric

SKU: LC1DT40P7

Original price was: ₹11,945.00.Current price is: ₹5,255.80. Excl. GST

Dispatch By : 7 Weeks

Dispatch By : 7 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: LC1DT40P7

Same-day dispatch · GST invoice available

10 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LC1DT40P7 | TeSys contactor 4P AC1 440V 40 A? This genuine Schneider Electric contactor from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 40 A, Power circuit: <= 690 V AC 25...400 Hz, 4P. Order part number LC1DT40P7 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULC1DT40P7
CategoryContactor
Main
RangeTeSys
TeSys Deca
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage230 V AC 50/60 Hz
Complementary
Compatibility codeLC1D
Pole contact composition4 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit
40 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current50 A 40 °C – 10 min for power circuit
120 A 40 °C – 1 min for power circuit
240 A 40 °C – 10 s for power circuit
380 A 40 °C – 1 s for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuit
Average impedance2 mOhm – Ith 40 A 50 Hz for power circuit
Power dissipation per pole3.2 W AC-1
[Ui] rated insulation voltagePower circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability15 Mcycles
Electrical durability1.4 Mcycles 40 A AC-1 at Ue <= 440 V
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W at 50/60 Hz
Operating time4…19 ms opening
12…22 ms closing
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…16 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 1.8 N.m – on screw clamps terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.8 N.m – on screw clamps terminals – with screwdriver Philips No 2
Power circuit: 1.8 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting supportRail
Plate
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1
Product certificationsCCC
LROS (Lloyds register of shipping)
RINA
UL
DNV
BV
CSA
GL
GOST
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms)
Height91 mm
Width45 mm
Depth99 mm
Product weight0.425 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.500 cm
Package 1 Width9.500 cm
Package 1 Length11.700 cm
Package 1 Weight471.000 g
Unit Type of Package 2S02
Number of Units in Package 216
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.996 kg
Unit Type of Package 3P06
Number of Units in Package 3256
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight136.560 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 40 A AC-3 rated — suits up to a 18.5 kW squirrel-cage induction motor at 415V for direct-on-line (DOL) starting and running.
  • 4 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
  • Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LAD9ET1SLAD4RCULAD4VULADN22LADN11LADN20LAD8N11LADT2LADN40LADN31LADN02LADT0LAD8N20LADS2LADR2LADR0LADN04LADN13LADR4LADT4LAD8N02LXD1P7

❓ Frequently Asked Questions

Q: Is the LC1DT40P7 rated 40 A for AC-3 motor duty or AC-1 resistive duty?

A: The 40 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.

Q: What is the electrical and mechanical life of the LC1DT40P7?

A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.

Q: Can the LC1DT40P7 be used for reversing duty (forward/reverse motor control)?

A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.

Q: Can multiple LC1DT40P7 contactors be wired for star-delta starting?

A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.

Q: Which Schneider Electric accessories are compatible with the LC1DT40P7?

A: The Schneider Electric LC1DT40P7 series supports snap-on accessories including auxiliary contact blocks, coil surge suppressors, mechanical interlocks, and direct-mount overload relays. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the LC1DT40P7.