A9KR11225 | Acti 9K RCCB 2P 25A 30 mA AC-type – Schneider Electric
₹3,610.00 Original price was: ₹3,610.00.₹1,949.40Current price is: ₹1,949.40. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
The Schneider Electric A9KR11225 is a rccb, engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 25 A, 2 Poles. Buy the A9KR11225 | Acti 9K RCCB 2P 25A 30 mA AC-type online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Part Number / SKU | A9KR11225 |
| Category | RCCB |
| Current Rating | 25 A |
| Poles | 2 Poles |
| Sensitivity | 30 mA |
| Rated Voltage | 230V AC |
| Rated Frequency | 50 Hz |
| Max Break Time | ≤ 300 ms at rated IΔn (per IEC 61008-1) |
| RCD Type | Type AC (sinusoidal AC sensitive) |
| Protection Function | Earth leakage only — pair with upstream MCB for overcurrent |
| Mounting | 35mm DIN rail (EN 60715) |
| Test Facility | Built-in test button (monthly test per IS 12640) |
| Standard | IEC 61008 / IS 12640-1 |
| Certifications | BIS certified, CE marked, RoHS compliant |
⚡ Key Features
- 30 mA sensitivity — standard personnel shock protection — trips before a lethal current (>50mA) can flow through the body (IEC 61008).
- 25 A rated load current — the RCCB carries this full circuit current continuously while monitoring the live-neutral balance for any earth leakage.
- 2 Poles — for single-phase circuits; both live and neutral pass through the sensing core.
- Earth-leakage protection only — no overload or short-circuit protection; install in series with an appropriately rated MCB for full circuit protection.
- Mandatory test button — simulate a leakage fault to verify the trip mechanism without live fault conditions; test monthly per IS 12640 recommendation.
- Type AC — designed for purely sinusoidal AC residual currents on standard residential and commercial circuits.
- Manufactured to IEC 61008 / IS 12640-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
❓ Frequently Asked Questions
Q: What is the significance of the 25 A rating on the A9KR11225?
A: The 25 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.
Q: Why is the 30 mA sensitivity specified on the A9KR11225 and when should you choose a different rating?
A: 30 mA is the residual current at which the A9KR11225 will trip within 300ms. A 30mA sensitivity provides additional shock protection (mandatory for socket circuits per IS 732). 100mA is used for fire protection (no shock protection). 300mA protects feeders without nuisance tripping. Choose based on the circuit’s risk profile — never use >30mA for socket outlet circuits in wet or high-risk locations.
Q: How many downstream circuits can be protected under the A9KR11225 without nuisance tripping?
A: Downstream MCBs or RCBOs can be connected below the A9KR11225, but the total standing leakage current of all connected circuits must not exceed 30–50% of the RCCB’s rated sensitivity — typically 9–15mA for a 30mA device. Each appliance with a filter (computers, VFDs, LED drivers) contributes 0.5–3mA of standing leakage, so limit the count of such loads per RCCB to prevent cumulative leakage causing nuisance tripping.
Q: Will the A9KR11225 trip on earth faults from variable frequency drives (VFDs)?
A: VFDs, LED drivers, and switched-mode power supplies generate high-frequency leakage currents that can cause nuisance tripping in standard Type AC RCCBs. If your installation includes VFDs, use a Type A (for pulsating DC components) or Type F/B RCCB. The A9KR11225 specification (AC or A type) determines suitability — check the product marking.
Q: Which Schneider Electric accessories are compatible with the A9KR11225?
A: The Schneider Electric A9KR11225 series supports snap-on accessories including auxiliary contacts (OF), alarm contacts (SD), shunt trip coils (MX), undervoltage releases (MN), and comb busbars. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the A9KR11225.