VCF2 | TeSys Vario – emergency stop switch disconnector – 40 A – on door – Schneider Electric
₹7,200.00 Original price was: ₹7,200.00.₹4,104.00Current price is: ₹4,104.00. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
VZ2 | TeSys VARIO – additional pole – 40 A – for V2 – Schneider Electric
VZ8 | 3 POLE INPUT TERMI- COVER – Schneider Electric
VZ14 | PE TERMINAL 40A – Schneider Electric
VZ11 | TeSys VARIO – additional neutral block – 40 A – for V02…V2 – Schneider Electric
VZ7 | TeSys VARIO – auxiliary contact block – 1 NC early-break+1 NO late-make – Schneider Electric
VZ20 | TeSys VARIO – auxiliary contact block – 1 NO + 1 NO – Schneider Electric
Sourced through authorised channels, the Schneider Electric VCF2 switch disconnector from the TeSys range delivers dependable performance for reliable circuit protection and isolation. Key ratings include 29 A AC-23 Ue: 400 V, 690 V AC 50/60 Hz, 3P. myelectric.in stocks the VCF2 | TeSys Vario – emergency stop switch disconnector – 40 A – on door for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | VCF2 |
| Category | Switch Disconnector |
| Main | |
| Range | TeSys |
| Product Name | TeSys VARIO |
| Device Short Name | VCF |
| Product Type | Emergency stop switch disconnector |
| Complementary | |
| Device Composition | Switch Handle |
| Mounting Support | Handle: door Switch: door |
| Mounting Method | By 4 screws for handle |
| Performance Level | High performance |
| Number of Poles | 3P |
| Contact Type and Composition | 3 NO |
| [Ue] IEC Rated Operational Voltage | 690 V AC 50/60 Hz |
| IEC Rated Operational Power in W | 11 kW at 690 V (AC-3) 15 kW at 690 V (AC-23A) 11 kW at 400…415 V (AC-3) 15 kW at 500 V (AC-3) 18.5 kW at 500 V (AC-23A) 5.5 kW at 230…240 V (AC-3) 7.5 kW at 230…240 V (AC-23A) 15 kW at 400…415 V (AC-23A) |
| [Ie] Rated Operational Current | 29 A AC-23 Ue: 400 V |
| [Ith] Conventional Free Air Thermal Current | 40 A |
| [Ithe] Conventional Enclosed Thermal Current | 32 A |
| Making Capacity ( I Rms) | 400 A at 400 V AC-21A 400 A at 400 V AC-22A 400 A at 400 V AC-23A |
| Breaking Capacity | 320 A at 400 V (AC-21A) 320 A at 400 V (AC-22A) 320 A at 400 V (AC-23A) |
| Rated Conditional Short Circuit Current | 10 kA at 400 V – associated fuse 50 A aM 10 kA at 400 V – associated fuse 50 A gG |
| [Icm] Rated Short Circuit Making Capacity | 1 kA at 400 V at Ipeak |
| [Icw] Rated Short Time Withstand Current | 480 A at 400 V duration: 1 s |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| Suitability for Isolation | Yes |
| Network Type | AC DC |
| Intermittent Duty Class | 30 |
| Control Type | Rotary handle |
| Rotary Handle Mounting Style | Direct |
| Handle Color | Red |
| Handle Front Plate Color | Yellow |
| Rotary Handle Padlocking | 1 to 3 padlocks 4…8 mm |
| Marking | 0 – 1 |
| Mechanical Durability | 100000 cycles |
| Electrical Durability | 100000 cycles AC-21 30000 cycles DC-1…5 |
| IEC Terminal Connection | Power circuit: screw clamp terminals10 mm² – solid Power circuit: screw clamp terminals6 mm² – flexible – with cable end |
| Tightening Torque | Power circuit: 2.1 N.m – on screw clamp terminals |
| Base Dimension | 60 x 60 mm |
| Height | 74 mm |
| Width | 60 mm |
| Product Weight | 0.25 kg |
| Environment | |
| Standards | IEC 60947-3 |
| Product Certifications | UL CCC GL CSA UKCA |
| Degree of Protection | IP20 conforming to IEC 60529 IP65 |
| Protective Treatment | TC |
| Mechanical Robustness | Vibrations 10…150 Hz (1 gn) conforming to IEC 60068-2-6 Shocks 11 ms (30 Gn) conforming to IEC 60068-2-27 |
| Ambient Air Temperature for Operation | -20…50 °C |
| Fire Resistance | 960 °C conforming to IEC 60695-2-1 |
| Compatibility Code | Main switch disconnector |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.300 cm |
| Package 1 Width | 8.300 cm |
| Package 1 Length | 12.500 cm |
| Package 1 Weight | 223.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.737 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 192 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 55.308 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 40 A current rating — confirmed from product specifications; size wiring and terminals to match or exceed this value.
- Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What is the significance of the 40 A rating on the VCF2?
A: The 40 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.
Q: How many padlocks can be applied to the VCF2 for LOTO safety?
A: The Schneider Electric switch disconnector supports up to 3 simultaneous padlocks on the OFF-position locking facility. This allows multiple contractors or maintenance teams to each apply their own padlock, ensuring the circuit cannot be re-energised until all teams have removed their lock — a critical requirement for multi-contractor LOTO procedures.
Q: Can the VCF2 make and break load current, or is it for isolation only?
A: This is a switch-disconnector (not a pure isolator), meaning it is rated to make and break load currents up to its rated current under AC-22A or AC-23A utilisation categories. Pure isolators must only be operated on de-energised circuits. The Schneider Electric switch-disconnector can therefore be used for operational switching, not just maintenance isolation.