VPL12N Varplus Logic Controller, 12 Step Output Schneider Electric vpl12n iopmain oda19 1500x1500
VPL12N | Varplus Logic Controller, 12 Step Output - Schneider Electric Original price was: ₹70,461.00.Current price is: ₹26,775.18. Excl. GST
Back to products
TM3TI4G MODULE TM3-4 INPUTS TEMPERATURE SPRING Schneider Electric pf130354 1500x1500
TM3TI4G | MODULE TM3-4 INPUTS TEMPERATURE SPRING - Schneider Electric Original price was: ₹50,881.00.Current price is: ₹18,317.16. Excl. GST

GV5P220H | GV5P220H 3P 70kA Motor Circuit Breaker – Schneider Electric

SKU: GV5P220H

Original price was: ₹90,705.00.Current price is: ₹40,817.25. Excl. GST

Out of stock

Out of stock

11 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Sourced through authorised channels, the Schneider Electric GV5P220H motor protection circuit breaker (mpcb) from the TeSys range delivers dependable performance for reliable circuit protection and isolation. Key ratings include 220 A at 65 °C, 690 V AC 50/60 Hz, 3P. myelectric.in stocks the GV5P220H | GV5P220H 3P 70kA Motor Circuit Breaker for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUGV5P220H
CategoryMotor Protection Circuit Breaker (MPCB)
Main
RangeTeSys
Range of productTeSys GV5
Device short nameGV5P
Product nameTeSys GV5
TeSys Giga
Product or component typeMotor circuit breaker
Device applicationMotor protection
Trip unit technologyElectronic
Complementary
Poles description3P
Utilisation categoryCategory A conforming to IEC 60947-2
Motor power kW90…110 kW at 400/415 V AC 50/60 Hz
110 kW at 500 V AC 50/60 Hz
110…132 kW at 660/690 V AC 50/60 Hz
Breaking capacity70 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeDirect rotary handle
[In] rated current220 A at 65 °C
Magnetic tripping current3300 A
Rated conditional short-circuit current60 kA at 440 V
[Ue] rated operational voltage690 V AC 50/60 Hz
[Ui] rated insulation voltage800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current220 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage8 kV
Power dissipation per pole17.6 W
Mechanical durability20000 cycles
Electrical durability5000 cycles for AC-3 at 415 V opening
5000 cycles for AC-3 at 415 V closing
maximum operating rate25 cyc/h
Rated dutyContinuous
Connection pitch35 mm without spreaders
Connections – terminalsBars
Lugs
Tightening torque15 N.m M8 screw type
Mechanical robustnessVibrations: +/- 1 mm 2…13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2…100 Hz conforming to IEC 60068-2-6
Phase failure sensitivityYes conforming to IEC 60947-4-1
Height161 mm
Width105 mm
Depth155 mm
Product weight2.6 kg
ColourAnthracite (RAL 7016)
Suitability for isolationYes conforming to EN/IEC 60947-2
Environment
StandardsEN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsIECEE CB Scheme
EAC (pending)
Climatic withstandconforming to IACS E10
IK degree of protectionIK07 conforming to IEC 62262
IP degree of protectionIP40 conforming to IEC 60529
Ambient air temperature for storage-50…85 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Operating altitude5000 m
Ambient air temperature for operation-25…70 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height19.1 cm
Package 1 Width11.8 cm
Package 1 Length17.0 cm
Package 1 Weight2.9 kg
Unit Type of Package 2S04
Number of Units in Package 26
Package 2 Height30.0 cm
Package 2 Width40.0 cm
Package 2 Length60.0 cm
Package 2 Weight18.1 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 70 kA short-circuit breaking capacity — the MPCB alone handles fault interruption; no separate backup fuse required for short-circuit protection in this duty range.
  • Combined thermal and magnetic protection in one device — single MPCB replaces a separate motor-rated MCB plus thermal overload relay, saving DIN rail space and inter-device wiring.
  • Phase-loss and phase-unbalance detection — trips within seconds of a phase failure, protecting the motor from the severe overheating that single-phasing causes within minutes.
  • Manual reset only — operator must acknowledge and reset the MPCB after a trip, preventing automatic restart that could damage the motor or driven machinery.
  • Manufactured to IEC 60947-4-1 and IEC 60947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

GV7AC01GV7AC021GV7AP02GV7AP01GV7AP05GV7AC022GV7AC04GV7AC03GV7AC08

❓ Frequently Asked Questions

Q: What does the 70 kA breaking capacity on the GV5P220H mean in practice?

A: Breaking capacity (70 kA) is the maximum prospective short-circuit current the GV5P220H can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 70 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: What is the trip class of the GV5P220H and what motor starting time does it allow?

A: MPCBs are typically rated Class 10 (trips in ≤10 seconds at 7.2× setting current), suitable for normal motors with DOL starting times up to 10 seconds. Heavy-duty motors (large fans, centrifuges, compressors) with longer starting times may need Class 20 or Class 30 protection — check the starting time against the motor’s speed-torque curve and select accordingly.

Q: Can the GV5P220H replace a contactor + overload relay combination in a motor circuit?

A: The GV5P220H provides motor short-circuit protection and overload protection in one device — but it cannot make/break motor current under normal operational switching (that is the contactor’s role). For motor starters requiring on/off switching, the GV5P220H is used as the upstream protection device with a contactor for switching. Some MPCB series include a direct handle for manual starting of small motors without a separate contactor.

Q: After a short-circuit trip on the GV5P220H, can it be reset and reused immediately?

A: After a short-circuit trip, do not immediately reset the GV5P220H. First, identify and clear the fault. Then inspect the device — if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 70 kA rated breaking capacity is not unlimited — it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1–3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.

Q: What is the difference between a Motor Protection Circuit Breaker (MPCB) and a standard MCB — and why use the GV5P220H?

A: A standard MCB protects against overload and short-circuit only. A Motor Protection Circuit Breaker (MPCB) adds adjustable thermal overload matched to motor FLC, Class 10/20 trip curves for motor starting inrush, and phase-loss sensitivity — making it the correct device for motor branch circuits where a standard MCB would either nuisance-trip on motor starting or fail to protect adequately against slow overloads. Choose the GV5P220H when the application specifically requires motor protection circuit breaker (mpcb) characteristics.

Customer Reviews