LC1E1801M5 | 3P Contactor Tesys E 1Nc 7,5Kw 400V Ac3 – Schneider Electric
₹3,465.00 Original price was: ₹3,465.00.₹1,489.95Current price is: ₹1,489.95. Excl. GST
Dispatch By : 5 Weeks
Dispatch By : 5 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LAEN02 | EasyPact TVS – auxiliary contact block – 2 NC – screw-clamps terminals – Schneider Electric
LAEM1 | EasyPact TVS – mechanical interlock – for LC1E06…E65 – Schneider Electric
LAEN22 | EasyPact TVS – auxiliary contact block – 2 NO + 2 NC – screw-clamps terminals – Schneider Electric
LAEN11 | EasyPact TVS – auxiliary contact block – 1 NO + 1 NC – screw-clamps terminals – Schneider Electric
LAEN20 | EasyPact TVS – auxiliary contact block – 2 NO – screw-clamps terminals – Schneider Electric
LAERCU | RC SURGE BLOCK 110 240 VAC EasyPact TVS – Schneider Electric
Looking for the LC1E1801M5 | 3P Contactor Tesys E 1Nc 7,5Kw 400V Ac3? This genuine Schneider Electric contactor from the Easy TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 18 A, Power circuit: <= 690 V AC 50/60 Hz, 3P. Order part number LC1E1801M5 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LC1E1801M5 |
| Category | Contactor |
| Main | |
| Range | Easy TeSys |
| Range of product | Easy TeSys Control |
| Product or component type | Contactor |
| Device short name | LC1E |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-3 AC-3e AC-1 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
| [Ie] rated operational current | 18 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 18 A (at <55 °C) at <= 440 V AC AC-3e for power circuit 32 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 220 V AC 50 Hz |
| Complementary | |
| Motor power kW | 4 kW at 220/230 V AC 50/60 Hz 7.5 kW at 380/400 V AC 9 kW at 415/440 V AC 9 kW at 500 V AC 9 kW at 660/690 V AC 10 kW at 660…690 V |
| Pole contact composition | 3 NO |
| [Ith] conventional free air thermal current | 32 A (at 55 °C) for power circuit |
| Irms rated making capacity | 234 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
| Rated breaking capacity | 153 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 145 A 40 °C – 10 s for power circuit 84 A 40 °C – 60 s for power circuit 40 A 40 °C – 600 s for power circuit |
| Associated fuse rating | 35 A gG at <= 690 V coordination type 1 for power circuit 10 A gG at <= 690 V for auxiliary contact circuit conforming to IEC 60947-5-1 |
| Average impedance | 2.5 mOhm – Ith 32 A 50 Hz for power circuit |
| Power dissipation per pole | 0.81 W AC-3 2.6 W AC-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
| Mechanical durability | 10000000 cycles |
| Electrical durability | 300000 cycles AC-1 1200000 cycles AC-3 |
| Control circuit type | AC at 50 Hz |
| Control circuit voltage limits | 0.85…1.1 Uc (-5…55 °C):operational 50 Hz 0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz |
| Inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W for control circuit |
| Operating time | 12…22 ms on closing 4…19 ms on opening |
| Maximum operating rate | 1800 cyc/h 60 °C |
| Connections – terminals | Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 1.5…6 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1.5…6 mm² – cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: solid without cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end |
| Tightening torque | Power circuit: 1.2 N.m Control circuit: 1.2 N.m |
| Auxiliary contact composition | 1 NC |
| Minimum switching voltage | 17 V for auxiliary contact circuit |
| Minimum switching current | 5 mA for auxiliary contact circuit |
| Insulation resistance | > 10 MOhm for auxiliary contact circuit |
| Non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
| Mounting support | Plate DIN rail |
| Environment | |
| Standards | EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ IS/IEC 60947-1 IS/IEC 60947-4-1 IS/IEC 60947-5-1 |
| Product certifications | CB Scheme CCC CE EAC BIS |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db |
| Permissible ambient air temperature around the device | -20…70 °C at Uc -60…80 °C storage -5…55 °C operation |
| Operating altitude | 3000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contactor open (1.5 Gn, 5…300 Hz) Vibrations contactor closed (3 Gn, 5…300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms) |
| Height | 74 mm |
| Width | 45 mm |
| Depth | 80 mm |
| Product weight | 0.3 kg |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 7.700 cm |
| Package 1 Length | 8.900 cm |
| Package 1 Weight | 339.800 g |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 3 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
- Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What does the 1 NC (Normally Closed) contact configuration on the LC1E1801M5 mean?
A: These contacts change state when the device is operated or energised. Size the contact for the actual switched load — pilot duty ratings are typically lower than the main contact rating.
Q: What is the electrical and mechanical life of the LC1E1801M5?
A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.
Q: Can the LC1E1801M5 be used for reversing duty (forward/reverse motor control)?
A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.
Q: Can multiple LC1E1801M5 contactors be wired for star-delta starting?
A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.
Q: Which Schneider Electric accessories are compatible with the LC1E1801M5?
A: The Schneider Electric LC1E1801M5 series supports snap-on accessories including auxiliary contact blocks, coil surge suppressors, mechanical interlocks, and direct-mount overload relays. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the LC1E1801M5.