CAE22N5 | CONTROL RELAY EasyPact TVS 2NO 2NC COIL – Schneider Electric
₹2,815.00 Original price was: ₹2,815.00.₹1,182.30Current price is: ₹1,182.30. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LAEN22 | EasyPact TVS – auxiliary contact block – 2 NO + 2 NC – screw-clamps terminals – Schneider Electric
LAEN20 | EasyPact TVS – auxiliary contact block – 2 NO – screw-clamps terminals – Schneider Electric
LAEN11 | EasyPact TVS – auxiliary contact block – 1 NO + 1 NC – screw-clamps terminals – Schneider Electric
LAEN02 | EasyPact TVS – auxiliary contact block – 2 NC – screw-clamps terminals – Schneider Electric
LAERCN | RC SURGE BLOCK 380 415 VAC EasyPact TVS – Schneider Electric
Looking for the CAE22N5 | CONTROL RELAY EasyPact TVS 2NO 2NC COIL? This genuine Schneider Electric relay from the Easy TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include <= 690 V AC, IP2X. Order part number CAE22N5 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | CAE22N5 |
| Category | Relay |
| Main | |
| Range | Easy TeSys |
| Range of product | Easy TeSys Control Relay |
| Product or component type | Control relay |
| Device short name | CAE |
| Contactor application | Control circuit |
| Colour | Grey (RAL 7011) |
| Complementary | |
| Utilisation category | AC-15 AC-14 |
| Pole contact composition | 2 NO + 2 NC |
| [Ue] rated operational voltage | <= 690 V AC |
| Control circuit type | AC at 50 Hz |
| [Uc] control circuit voltage | 415 V AC 50 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| [Ith] conventional free air thermal current | 10 A (at 40 °C) |
| Irms rated making capacity | 140 A at 690 V AC conforming to IEC 60947-5-1 |
| [Icw] rated short-time withstand current | 120 A – 500 ms 140 A – 100 ms |
| Associated fuse rating | 10 A gG at 690 V conforming to IEC 60947-5-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1 |
| Mounting support | Rail Plate |
| Connections – terminals | Screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible without cable end Screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end Screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end Screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end Screw clamp terminals 1 1…2.5 mm² – cable stiffness: solid without cable end Screw clamp terminals 2 1…2.5 mm² – cable stiffness: solid without cable end |
| Recommended tightening torque | 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2 |
| Control circuit voltage limits | Operational: 0.85…1.1 Uc at 50 Hz Drop-out: 0.3…0.6 Uc |
| Operating time | 4…19 ms coil energisation and NC opening 12…22 ms coil energisation and NO closing 4…12 ms coil de-energisation and NC opening 6…17 ms coil de-energisation and NO closing |
| Mechanical durability | 10 Mcycles |
| Maximum operating rate | 180 cyc/mn |
| Inrush power in VA | 70 VA 50 Hz (at 20 °C) |
| Hold-in power consumption in VA | 8 VA 50 Hz (at 20 °C) |
| Minimum switching voltage | 17 V |
| Minimum switching current | 5 mA |
| Non-overlap time | 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Mechanical robustness | Shocks control relay open: 7 Gn for 11 ms Shocks control relay closed: 10 Gn for 11 ms Vibrations control relay open: 1.5 Gn, 5…300 Hz Vibrations control relay closed: 3 Gn, 5…300 Hz |
| Height | 74 mm |
| Width | 45 mm |
| Depth | 80 mm |
| Product weight | 0.28 kg |
| Environment | |
| Standards | EN/IEC 60947-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.5 IS/IEC 60947-1 IS/IEC 60947-5-1 |
| Product certifications | CB Scheme CCC CE EAC BIS |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -20…70 °C |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 3000 m without derating |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.100 cm |
| Package 1 Width | 7.800 cm |
| Package 1 Length | 9.100 cm |
| Package 1 Weight | 298.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 36 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 11.435 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 576 |
| Package 3 Height | 115.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 175.680 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 2 NO (normally-open) contacts for load switching and sequencing; 2 NC (normally-closed) contacts for interlocking, fail-safe, and alarm circuits — all contacts independently switchable up to the contact voltage rating.
- Manufactured to IEC 60947-5-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: How do I test the CAE22N5 relay in the field without a signal source?
A: Most Schneider Electric relays can be manually forced using the test button (if fitted) — this mechanically closes the relay contacts without energising the coil, allowing functional testing of the controlled circuit. For coil testing, use a multimeter to measure coil resistance (typically 500–2000Ω for AC coils at rated voltage) and compare with datasheet values.
Q: Can the CAE22N5 relay be mounted on a DIN rail socket for easy replacement?
A: This Schneider Electric relay typically requires direct panel or DIN rail wiring. For applications requiring frequent relay replacement, consider the plug-in relay variant of this series with a matching socket base.